The sponge pump: the role of current induced flow in the design of the sponge body plan.

Sponges are suspension feeders that use flagellated collar-cells (choanocytes) to actively filter a volume of water equivalent to many times their body volume each hour. Flow through sponges is thought to be enhanced by ambient current, which induces a pressure gradient across the sponge wall, but t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sally P Leys, Gitai Yahel, Matthew A Reidenbach, Verena Tunnicliffe, Uri Shavit, Henry M Reiswig
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2011
Materias:
R
Q
Acceso en línea:https://doaj.org/article/509726a72da2419594dbb614bbbe1a87
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:509726a72da2419594dbb614bbbe1a87
record_format dspace
spelling oai:doaj.org-article:509726a72da2419594dbb614bbbe1a872021-11-18T07:32:25ZThe sponge pump: the role of current induced flow in the design of the sponge body plan.1932-620310.1371/journal.pone.0027787https://doaj.org/article/509726a72da2419594dbb614bbbe1a872011-01-01T00:00:00Zhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/22180779/?tool=EBIhttps://doaj.org/toc/1932-6203Sponges are suspension feeders that use flagellated collar-cells (choanocytes) to actively filter a volume of water equivalent to many times their body volume each hour. Flow through sponges is thought to be enhanced by ambient current, which induces a pressure gradient across the sponge wall, but the underlying mechanism is still unknown. Studies of sponge filtration have estimated the energetic cost of pumping to be <1% of its total metabolism implying there is little adaptive value to reducing the cost of pumping by using "passive" flow induced by the ambient current. We quantified the pumping activity and respiration of the glass sponge Aphrocallistes vastus at a 150 m deep reef in situ and in a flow flume; we also modeled the glass sponge filtration system from measurements of the aquiferous system. Excurrent flow from the sponge osculum measured in situ and in the flume were positively correlated (r>0.75) with the ambient current velocity. During short bursts of high ambient current the sponges filtered two-thirds of the total volume of water they processed daily. Our model indicates that the head loss across the sponge collar filter is 10 times higher than previously estimated. The difference is due to the resistance created by a fine protein mesh that lines the collar, which demosponges also have, but was so far overlooked. Applying our model to the in situ measurements indicates that even modest pumping rates require an energetic expenditure of at least 28% of the total in situ respiration. We suggest that due to the high cost of pumping, current-induced flow is highly beneficial but may occur only in thin walled sponges living in high flow environments. Our results call for a new look at the mechanisms underlying current-induced flow and for reevaluation of the cost of biological pumping and its evolutionary role, especially in sponges.Sally P LeysGitai YahelMatthew A ReidenbachVerena TunnicliffeUri ShavitHenry M ReiswigPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 6, Iss 12, p e27787 (2011)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Sally P Leys
Gitai Yahel
Matthew A Reidenbach
Verena Tunnicliffe
Uri Shavit
Henry M Reiswig
The sponge pump: the role of current induced flow in the design of the sponge body plan.
description Sponges are suspension feeders that use flagellated collar-cells (choanocytes) to actively filter a volume of water equivalent to many times their body volume each hour. Flow through sponges is thought to be enhanced by ambient current, which induces a pressure gradient across the sponge wall, but the underlying mechanism is still unknown. Studies of sponge filtration have estimated the energetic cost of pumping to be <1% of its total metabolism implying there is little adaptive value to reducing the cost of pumping by using "passive" flow induced by the ambient current. We quantified the pumping activity and respiration of the glass sponge Aphrocallistes vastus at a 150 m deep reef in situ and in a flow flume; we also modeled the glass sponge filtration system from measurements of the aquiferous system. Excurrent flow from the sponge osculum measured in situ and in the flume were positively correlated (r>0.75) with the ambient current velocity. During short bursts of high ambient current the sponges filtered two-thirds of the total volume of water they processed daily. Our model indicates that the head loss across the sponge collar filter is 10 times higher than previously estimated. The difference is due to the resistance created by a fine protein mesh that lines the collar, which demosponges also have, but was so far overlooked. Applying our model to the in situ measurements indicates that even modest pumping rates require an energetic expenditure of at least 28% of the total in situ respiration. We suggest that due to the high cost of pumping, current-induced flow is highly beneficial but may occur only in thin walled sponges living in high flow environments. Our results call for a new look at the mechanisms underlying current-induced flow and for reevaluation of the cost of biological pumping and its evolutionary role, especially in sponges.
format article
author Sally P Leys
Gitai Yahel
Matthew A Reidenbach
Verena Tunnicliffe
Uri Shavit
Henry M Reiswig
author_facet Sally P Leys
Gitai Yahel
Matthew A Reidenbach
Verena Tunnicliffe
Uri Shavit
Henry M Reiswig
author_sort Sally P Leys
title The sponge pump: the role of current induced flow in the design of the sponge body plan.
title_short The sponge pump: the role of current induced flow in the design of the sponge body plan.
title_full The sponge pump: the role of current induced flow in the design of the sponge body plan.
title_fullStr The sponge pump: the role of current induced flow in the design of the sponge body plan.
title_full_unstemmed The sponge pump: the role of current induced flow in the design of the sponge body plan.
title_sort sponge pump: the role of current induced flow in the design of the sponge body plan.
publisher Public Library of Science (PLoS)
publishDate 2011
url https://doaj.org/article/509726a72da2419594dbb614bbbe1a87
work_keys_str_mv AT sallypleys thespongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT gitaiyahel thespongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT matthewareidenbach thespongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT verenatunnicliffe thespongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT urishavit thespongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT henrymreiswig thespongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT sallypleys spongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT gitaiyahel spongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT matthewareidenbach spongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT verenatunnicliffe spongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT urishavit spongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
AT henrymreiswig spongepumptheroleofcurrentinducedflowinthedesignofthespongebodyplan
_version_ 1718423283181813760