Control of the CO2 Capture Using the Absorption and Stripping System for Improved Performance
The paper presents a new control system configuration for the post combustion CO2 carbon capture process using amines. The control system structure consists in six control loops and has in its core the cascade control strategy. The proposed cascade control system has the desired carbon capture rate...
Guardado en:
Autores principales: | , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
AIDIC Servizi S.r.l.
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/5139ac7760c64defbc9dff8e40b35567 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:5139ac7760c64defbc9dff8e40b35567 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:5139ac7760c64defbc9dff8e40b355672021-11-15T21:48:42ZControl of the CO2 Capture Using the Absorption and Stripping System for Improved Performance10.3303/CET21880432283-9216https://doaj.org/article/5139ac7760c64defbc9dff8e40b355672021-11-01T00:00:00Zhttps://www.cetjournal.it/index.php/cet/article/view/11836https://doaj.org/toc/2283-9216The paper presents a new control system configuration for the post combustion CO2 carbon capture process using amines. The control system structure consists in six control loops and has in its core the cascade control strategy. The proposed cascade control system has the desired carbon capture rate as the master controller target, and the molar ratio between the lean MEA and the influent CO2 flowrates as the slave controller manipulated setpoint. They have associated the reboiler temperature control in the stripper and the concentration of MEA, temperature and level control in the buffer tank. The buffer tank, accompanied by its control loops, was specifically introduced in the carbon capture plant in order to reduce the interaction between the absorption and stripping units. The decentralized control system was tested for assessing its performance to cope with the typical influent CO2 flowrate disturbance, considered to act in a periodic scenario. Good disturbance rejection and effective restoration of the nominal operation state were achieved, while the energy performance index value was kept at reduced values. They demonstrate valuable operation flexibility of the controlled CO2 carbon capture plant.Flavia IleaVasile-Mircea CristeaAna-Maria CormosAIDIC Servizi S.r.l.articleChemical engineeringTP155-156Computer engineering. Computer hardwareTK7885-7895ENChemical Engineering Transactions, Vol 88 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Chemical engineering TP155-156 Computer engineering. Computer hardware TK7885-7895 |
spellingShingle |
Chemical engineering TP155-156 Computer engineering. Computer hardware TK7885-7895 Flavia Ilea Vasile-Mircea Cristea Ana-Maria Cormos Control of the CO2 Capture Using the Absorption and Stripping System for Improved Performance |
description |
The paper presents a new control system configuration for the post combustion CO2 carbon capture process using amines. The control system structure consists in six control loops and has in its core the cascade control strategy. The proposed cascade control system has the desired carbon capture rate as the master controller target, and the molar ratio between the lean MEA and the influent CO2 flowrates as the slave controller manipulated setpoint. They have associated the reboiler temperature control in the stripper and the concentration of MEA, temperature and level control in the buffer tank. The buffer tank, accompanied by its control loops, was specifically introduced in the carbon capture plant in order to reduce the interaction between the absorption and stripping units. The decentralized control system was tested for assessing its performance to cope with the typical influent CO2 flowrate disturbance, considered to act in a periodic scenario. Good disturbance rejection and effective restoration of the nominal operation state were achieved, while the energy performance index value was kept at reduced values. They demonstrate valuable operation flexibility of the controlled CO2 carbon capture plant. |
format |
article |
author |
Flavia Ilea Vasile-Mircea Cristea Ana-Maria Cormos |
author_facet |
Flavia Ilea Vasile-Mircea Cristea Ana-Maria Cormos |
author_sort |
Flavia Ilea |
title |
Control of the CO2 Capture Using the Absorption and Stripping System for Improved Performance |
title_short |
Control of the CO2 Capture Using the Absorption and Stripping System for Improved Performance |
title_full |
Control of the CO2 Capture Using the Absorption and Stripping System for Improved Performance |
title_fullStr |
Control of the CO2 Capture Using the Absorption and Stripping System for Improved Performance |
title_full_unstemmed |
Control of the CO2 Capture Using the Absorption and Stripping System for Improved Performance |
title_sort |
control of the co2 capture using the absorption and stripping system for improved performance |
publisher |
AIDIC Servizi S.r.l. |
publishDate |
2021 |
url |
https://doaj.org/article/5139ac7760c64defbc9dff8e40b35567 |
work_keys_str_mv |
AT flaviailea controloftheco2captureusingtheabsorptionandstrippingsystemforimprovedperformance AT vasilemirceacristea controloftheco2captureusingtheabsorptionandstrippingsystemforimprovedperformance AT anamariacormos controloftheco2captureusingtheabsorptionandstrippingsystemforimprovedperformance |
_version_ |
1718426785493811200 |