The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility

Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, Stavrenia C Koukoula, Georgios LabirisDepartment of Ophthalmology and Eye Institute of Thrace, Democritus University of Thrace, Alexandroupolis, GreecePurpose: To develop, characterize, and validate a prototype digital aqueous hu...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, et al
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2010
Materias:
Acceso en línea:https://doaj.org/article/51aa759189f04ec8857909973597711c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:51aa759189f04ec8857909973597711c
record_format dspace
spelling oai:doaj.org-article:51aa759189f04ec8857909973597711c2021-12-02T00:15:36ZThe digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility1177-54671177-5483https://doaj.org/article/51aa759189f04ec8857909973597711c2010-08-01T00:00:00Zhttp://www.dovepress.com/the-digital-aqueous-humor-outflow-meter-an-alternative-tool-for-screen-a5139https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, Stavrenia C Koukoula, Georgios LabirisDepartment of Ophthalmology and Eye Institute of Thrace, Democritus University of Thrace, Alexandroupolis, GreecePurpose: To develop, characterize, and validate a prototype digital aqueous humor outflow tonographer (DAHOM).Material and methods: The DAHOM was developed, characterized, and validated in three phases. Phase 1 involved construction of the sensor. This was broadly based on the fundamental design of a typical Schiotz tonographer with a series of improvements, including corneal indentation, which was converted to an electrical signal via a linear variable differential transducer, an analog signal which was converted to digital via ADC circuitry, and digital data acquisition and processing which was made possible by a serial port interface. Phase 2 comprised development of software for automated assessment of the outflow facility. Automated outflow facility assessment incorporated a series of fundamental improvements in comparison with traditional techniques, including software-based filtering of ripple noise and extreme variations, rigidity impact analysis, and evaluation of the impact of patient age, central corneal thickness, and ocular axial length. Phase 3 comprised characterization and validation of DAHOM, for which we developed an experimental setup using porcine cadaver eyes. DAHOM’s repeatability was evaluated by means of Cronbach’s alpha and intraclass correlation coefficient. The level of agreement with a standard Schiotz tonographer was evaluated by means of paired t-tests and Bland-Altman analysis in human eyes.Results: The experimental setup provided the necessary data for the characterization of DAHOM. A fourth order polynomial equation provided excellent fit (R square >0.999). DAHOM demonstrated high repeatability (Cronbach’s alpha ≥0.997; intraclass correlation coefficient ≥0.987) and an adequate level of agreement with a standard Schiotz tonographer.Conclusions: This study presents the development, characterization, and validation of a prototype digital tonographer. DAHOM demonstrates high repeatability and a sufficient level of agreement with a typical Schiotz tonographer, while its digital design remedies known vulnerabilities of conventional tonographers.Keywords: glaucoma, tonography, pressure, outflow facility, aqueous humor Vassilios P KozobolisEleftherios I PaschalisNikitas C Foudoulakiset alDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2010, Iss default, Pp 937-945 (2010)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Vassilios P Kozobolis
Eleftherios I Paschalis
Nikitas C Foudoulakis
et al
The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
description Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, Stavrenia C Koukoula, Georgios LabirisDepartment of Ophthalmology and Eye Institute of Thrace, Democritus University of Thrace, Alexandroupolis, GreecePurpose: To develop, characterize, and validate a prototype digital aqueous humor outflow tonographer (DAHOM).Material and methods: The DAHOM was developed, characterized, and validated in three phases. Phase 1 involved construction of the sensor. This was broadly based on the fundamental design of a typical Schiotz tonographer with a series of improvements, including corneal indentation, which was converted to an electrical signal via a linear variable differential transducer, an analog signal which was converted to digital via ADC circuitry, and digital data acquisition and processing which was made possible by a serial port interface. Phase 2 comprised development of software for automated assessment of the outflow facility. Automated outflow facility assessment incorporated a series of fundamental improvements in comparison with traditional techniques, including software-based filtering of ripple noise and extreme variations, rigidity impact analysis, and evaluation of the impact of patient age, central corneal thickness, and ocular axial length. Phase 3 comprised characterization and validation of DAHOM, for which we developed an experimental setup using porcine cadaver eyes. DAHOM’s repeatability was evaluated by means of Cronbach’s alpha and intraclass correlation coefficient. The level of agreement with a standard Schiotz tonographer was evaluated by means of paired t-tests and Bland-Altman analysis in human eyes.Results: The experimental setup provided the necessary data for the characterization of DAHOM. A fourth order polynomial equation provided excellent fit (R square >0.999). DAHOM demonstrated high repeatability (Cronbach’s alpha ≥0.997; intraclass correlation coefficient ≥0.987) and an adequate level of agreement with a standard Schiotz tonographer.Conclusions: This study presents the development, characterization, and validation of a prototype digital tonographer. DAHOM demonstrates high repeatability and a sufficient level of agreement with a typical Schiotz tonographer, while its digital design remedies known vulnerabilities of conventional tonographers.Keywords: glaucoma, tonography, pressure, outflow facility, aqueous humor
format article
author Vassilios P Kozobolis
Eleftherios I Paschalis
Nikitas C Foudoulakis
et al
author_facet Vassilios P Kozobolis
Eleftherios I Paschalis
Nikitas C Foudoulakis
et al
author_sort Vassilios P Kozobolis
title The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
title_short The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
title_full The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
title_fullStr The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
title_full_unstemmed The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
title_sort digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
publisher Dove Medical Press
publishDate 2010
url https://doaj.org/article/51aa759189f04ec8857909973597711c
work_keys_str_mv AT vassiliospkozobolis thedigitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
AT eleftheriosipaschalis thedigitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
AT nikitascfoudoulakis thedigitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
AT etal thedigitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
AT vassiliospkozobolis digitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
AT eleftheriosipaschalis digitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
AT nikitascfoudoulakis digitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
AT etal digitalaqueoushumoroutflowmeteranalternativetoolforscreeningofthehumaneyeoutflowfacility
_version_ 1718403865513033728