Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK
Mark D Mifflin,1 Xavier M Mortensen,1 Brent S Betts,1 Cole Gross,2 Brian Zaugg1 1Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, 2University of Nevada School of Medicine, Reno, NV, USA Purpose: To study the accuracy and reliability...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://doaj.org/article/5222b91dfce1486ba69b057d5a758647 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:5222b91dfce1486ba69b057d5a758647 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:5222b91dfce1486ba69b057d5a7586472021-12-02T02:39:49ZAccuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK1177-5483https://doaj.org/article/5222b91dfce1486ba69b057d5a7586472017-08-01T00:00:00Zhttps://www.dovepress.com/accuracy-of-alcon-wavelightreg-ex500-optical-pachymetry-during-lasik-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Mark D Mifflin,1 Xavier M Mortensen,1 Brent S Betts,1 Cole Gross,2 Brian Zaugg1 1Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, 2University of Nevada School of Medicine, Reno, NV, USA Purpose: To study the accuracy and reliability of optical pachymetry using the Alcon WaveLight EX500 during laser-assisted in situ keratomileusis (LASIK). Materials and methods: This was a retrospective chart review of 90 eyes from 45 patients who had undergone LASIK (mean age 35.2±8.2 years; 19 males, 26 females). The WaveLight FS200 femtosecond laser was programmed to cut LASIK flaps at a desired depth of 120 µm. Optical low-coherence reflectometry (WaveLight EX500) was used to measure central corneal thickness prior to lifting the flap, and the residual stromal bed immediately after excimer ablation. Flap thickness (FT) was calculated using simple subtraction. Optical coherence tomography (OCT) was used to measure central corneal thickness, flap thickness, and residual stromal bed in the postoperative period and the results compared to intraoperative measurements. Results: Mean programmed FS200 FT was 119 µm. Mean FT using EX500 optical pachymetry was 109 µm. The difference between FS200- programmed and EX500-measured FT was 9 µm (P<0.001). There was also a significant difference between the EX500 and OCT FT (109 µm vs 119 µm, respectively; P<0.001). Conclusion: FT values calculated using intraoperative EX500 optical pachymetry were significantly lower than programmed FS200 values or OCT measurements. Keywords: flap thickness, optical coherence tomography, femtosecond laserMifflin MDMortensen XMBetts BSGross CZaugg BDove Medical Pressarticleflap thicknessoptical coherence tomographyfemtosecond laserOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 11, Pp 1513-1517 (2017) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
flap thickness optical coherence tomography femtosecond laser Ophthalmology RE1-994 |
spellingShingle |
flap thickness optical coherence tomography femtosecond laser Ophthalmology RE1-994 Mifflin MD Mortensen XM Betts BS Gross C Zaugg B Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK |
description |
Mark D Mifflin,1 Xavier M Mortensen,1 Brent S Betts,1 Cole Gross,2 Brian Zaugg1 1Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT, 2University of Nevada School of Medicine, Reno, NV, USA Purpose: To study the accuracy and reliability of optical pachymetry using the Alcon WaveLight EX500 during laser-assisted in situ keratomileusis (LASIK). Materials and methods: This was a retrospective chart review of 90 eyes from 45 patients who had undergone LASIK (mean age 35.2±8.2 years; 19 males, 26 females). The WaveLight FS200 femtosecond laser was programmed to cut LASIK flaps at a desired depth of 120 µm. Optical low-coherence reflectometry (WaveLight EX500) was used to measure central corneal thickness prior to lifting the flap, and the residual stromal bed immediately after excimer ablation. Flap thickness (FT) was calculated using simple subtraction. Optical coherence tomography (OCT) was used to measure central corneal thickness, flap thickness, and residual stromal bed in the postoperative period and the results compared to intraoperative measurements. Results: Mean programmed FS200 FT was 119 µm. Mean FT using EX500 optical pachymetry was 109 µm. The difference between FS200- programmed and EX500-measured FT was 9 µm (P<0.001). There was also a significant difference between the EX500 and OCT FT (109 µm vs 119 µm, respectively; P<0.001). Conclusion: FT values calculated using intraoperative EX500 optical pachymetry were significantly lower than programmed FS200 values or OCT measurements. Keywords: flap thickness, optical coherence tomography, femtosecond laser |
format |
article |
author |
Mifflin MD Mortensen XM Betts BS Gross C Zaugg B |
author_facet |
Mifflin MD Mortensen XM Betts BS Gross C Zaugg B |
author_sort |
Mifflin MD |
title |
Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK |
title_short |
Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK |
title_full |
Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK |
title_fullStr |
Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK |
title_full_unstemmed |
Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK |
title_sort |
accuracy of alcon wavelight® ex500 optical pachymetry during lasik |
publisher |
Dove Medical Press |
publishDate |
2017 |
url |
https://doaj.org/article/5222b91dfce1486ba69b057d5a758647 |
work_keys_str_mv |
AT mifflinmd accuracyofalconwavelightregex500opticalpachymetryduringlasik AT mortensenxm accuracyofalconwavelightregex500opticalpachymetryduringlasik AT bettsbs accuracyofalconwavelightregex500opticalpachymetryduringlasik AT grossc accuracyofalconwavelightregex500opticalpachymetryduringlasik AT zauggb accuracyofalconwavelightregex500opticalpachymetryduringlasik |
_version_ |
1718402284462800896 |