Tear Film Characteristics During Wear of Daily Disposable Contact Lenses

Giancarlo Montani, Maurizio Martino Dipartimento di Matematica e Fisica “Ennio De Giorgi”, CERCA Università del Salento, Lecce, ItalyCorrespondence: Giancarlo MontaniDipartimento di Matematica e Fisica “Ennio De Giorgi”, CERCA Università...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Montani G, Martino M
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2020
Materias:
Acceso en línea:https://doaj.org/article/52b0fdcd9284403eb1fb037c094c8251
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:52b0fdcd9284403eb1fb037c094c8251
record_format dspace
spelling oai:doaj.org-article:52b0fdcd9284403eb1fb037c094c82512021-12-02T08:36:24ZTear Film Characteristics During Wear of Daily Disposable Contact Lenses1177-5483https://doaj.org/article/52b0fdcd9284403eb1fb037c094c82512020-06-01T00:00:00Zhttps://www.dovepress.com/tear-film-characteristics-during-wear-of-daily-disposable-contact-lens-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Giancarlo Montani, Maurizio Martino Dipartimento di Matematica e Fisica “Ennio De Giorgi”, CERCA Università del Salento, Lecce, ItalyCorrespondence: Giancarlo MontaniDipartimento di Matematica e Fisica “Ennio De Giorgi”, CERCA Università del Salento, Via per Arnesano, Lecce 73100, ItalyEmail giancarlo.montani@le.infn.itPurpose: To evaluate changes induced over time by three daily disposable (DD) contact lenses on tear meniscus height (TMH), pre-lens non-invasive break-up time (pre-lens NIBUT), tear film osmolarity (TO) and objective quality of vision (OQV).Patients and Methods: Forty-six subjects enrolled in this prospective open-label unmasked non-randomized simultaneous comparative cross-over study. For the first week of the study, subjects wore a nesofilcon A lens in the right eye and a delefilcon A lens in the left eye. After 3 days of washout, for the second week, subjects wore a nesofilcon A lens in the left eye and a stenfilcon A lens in the right eye. TMH, pre-lens NIBUT, TO and OQV were measured before contact lens fitting and for each contact lens combination on day 1 at 20 minutes and on day 7 after ≥ 8 hours of wear. OQV measurement included the changes of objective scatter index (OSI), the stability index (SI) and the fluctuation index (FI) calculated in a range of time of 20 s from a blink.Results: TMH was unchanged at 20 minutes wear of all lenses but was significantly reduced after 8 or more hours wear (on day 7) of delefilcon A and stenfilcon A, respectively. Pre-lens NIBUT was significantly reduced with all lenses, while no significant change in TO was observed with any lens. SI and FI increased significantly for all lenses at both wear times.Conclusion: While the presence of any contact lens on the eye challenges the tear film, nesofilcon A contact lenses, despite their high water content, compared to delefilcon A and stenfilcon A contact lenses, showed a lower overall effect. We speculate that superior tear film behavior while wearing nesofilcon A lenses may translate to improved subjective comfort, but this remains to be evaluated.Keywords: nesofilcon A, delefilcon A, stenfilcon A, quality of vision, pre-lens tear film stability, tear osmolarity, tear meniscus heightMontani GMartino MDove Medical Pressarticlenesofilcon adelefilcon astenfilcon aquality of visionpre-lens tear film stabilitytear osmolaritytear meniscus heightOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 1521-1531 (2020)
institution DOAJ
collection DOAJ
language EN
topic nesofilcon a
delefilcon a
stenfilcon a
quality of vision
pre-lens tear film stability
tear osmolarity
tear meniscus height
Ophthalmology
RE1-994
spellingShingle nesofilcon a
delefilcon a
stenfilcon a
quality of vision
pre-lens tear film stability
tear osmolarity
tear meniscus height
Ophthalmology
RE1-994
Montani G
Martino M
Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
description Giancarlo Montani, Maurizio Martino Dipartimento di Matematica e Fisica “Ennio De Giorgi”, CERCA Università del Salento, Lecce, ItalyCorrespondence: Giancarlo MontaniDipartimento di Matematica e Fisica “Ennio De Giorgi”, CERCA Università del Salento, Via per Arnesano, Lecce 73100, ItalyEmail giancarlo.montani@le.infn.itPurpose: To evaluate changes induced over time by three daily disposable (DD) contact lenses on tear meniscus height (TMH), pre-lens non-invasive break-up time (pre-lens NIBUT), tear film osmolarity (TO) and objective quality of vision (OQV).Patients and Methods: Forty-six subjects enrolled in this prospective open-label unmasked non-randomized simultaneous comparative cross-over study. For the first week of the study, subjects wore a nesofilcon A lens in the right eye and a delefilcon A lens in the left eye. After 3 days of washout, for the second week, subjects wore a nesofilcon A lens in the left eye and a stenfilcon A lens in the right eye. TMH, pre-lens NIBUT, TO and OQV were measured before contact lens fitting and for each contact lens combination on day 1 at 20 minutes and on day 7 after ≥ 8 hours of wear. OQV measurement included the changes of objective scatter index (OSI), the stability index (SI) and the fluctuation index (FI) calculated in a range of time of 20 s from a blink.Results: TMH was unchanged at 20 minutes wear of all lenses but was significantly reduced after 8 or more hours wear (on day 7) of delefilcon A and stenfilcon A, respectively. Pre-lens NIBUT was significantly reduced with all lenses, while no significant change in TO was observed with any lens. SI and FI increased significantly for all lenses at both wear times.Conclusion: While the presence of any contact lens on the eye challenges the tear film, nesofilcon A contact lenses, despite their high water content, compared to delefilcon A and stenfilcon A contact lenses, showed a lower overall effect. We speculate that superior tear film behavior while wearing nesofilcon A lenses may translate to improved subjective comfort, but this remains to be evaluated.Keywords: nesofilcon A, delefilcon A, stenfilcon A, quality of vision, pre-lens tear film stability, tear osmolarity, tear meniscus height
format article
author Montani G
Martino M
author_facet Montani G
Martino M
author_sort Montani G
title Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
title_short Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
title_full Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
title_fullStr Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
title_full_unstemmed Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
title_sort tear film characteristics during wear of daily disposable contact lenses
publisher Dove Medical Press
publishDate 2020
url https://doaj.org/article/52b0fdcd9284403eb1fb037c094c8251
work_keys_str_mv AT montanig tearfilmcharacteristicsduringwearofdailydisposablecontactlenses
AT martinom tearfilmcharacteristicsduringwearofdailydisposablecontactlenses
_version_ 1718398450385551360