Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic

(1) Background: Many schools and higher education settings have confronted the issue of reopening their facilities after the COVID-19 pandemic. In response, several airflow strategies spanning from adding portable air purifiers to major mechanical overhauls have been suggested to equip classrooms wi...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ali Mohammadi Nafchi, Vincent Blouin, Nigel Kaye, Andrew Metcalf, Katie Van Valkinburgh, Ehsan Mousavi
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/53310ebdd5d147b4a14f8ed6d48f1a8b
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:53310ebdd5d147b4a14f8ed6d48f1a8b
record_format dspace
spelling oai:doaj.org-article:53310ebdd5d147b4a14f8ed6d48f1a8b2021-11-25T17:25:45ZRoom HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic10.3390/en142274631996-1073https://doaj.org/article/53310ebdd5d147b4a14f8ed6d48f1a8b2021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/22/7463https://doaj.org/toc/1996-1073(1) Background: Many schools and higher education settings have confronted the issue of reopening their facilities after the COVID-19 pandemic. In response, several airflow strategies spanning from adding portable air purifiers to major mechanical overhauls have been suggested to equip classrooms with what is necessary to provide a safe and reliable environment. Yet, there are many unknowns about specific contributions of the building system and its design and performance on indoor air quality (IAQ) improvements. (2) Methods: this study examined the combined effect of ventilation type, airflow rates, and filtration on IAQ in five different classrooms. Experiments were conducted by releasing inert surrogate particles into the classrooms and measuring the concentrations in various locations of the room. (3) Results: we showed that while the distribution of particles in the space is a complex function of space geometry and air distribution configurations, the average decay rate of contaminants is proportional to the number of air changes per hour in the room. (4) Conclusions: rooms with a central HVAC system responded quicker to an internal source of contamination than rooms with only fan coil units. Furthermore, increasing the ventilation rate without improved filtration is an inefficient use of energy.Ali Mohammadi NafchiVincent BlouinNigel KayeAndrew MetcalfKatie Van ValkinburghEhsan MousaviMDPI AGarticlemechanical ventilationschool reopeningCOVID-19air qualitycontaminant controlHVACTechnologyTENEnergies, Vol 14, Iss 7463, p 7463 (2021)
institution DOAJ
collection DOAJ
language EN
topic mechanical ventilation
school reopening
COVID-19
air quality
contaminant control
HVAC
Technology
T
spellingShingle mechanical ventilation
school reopening
COVID-19
air quality
contaminant control
HVAC
Technology
T
Ali Mohammadi Nafchi
Vincent Blouin
Nigel Kaye
Andrew Metcalf
Katie Van Valkinburgh
Ehsan Mousavi
Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic
description (1) Background: Many schools and higher education settings have confronted the issue of reopening their facilities after the COVID-19 pandemic. In response, several airflow strategies spanning from adding portable air purifiers to major mechanical overhauls have been suggested to equip classrooms with what is necessary to provide a safe and reliable environment. Yet, there are many unknowns about specific contributions of the building system and its design and performance on indoor air quality (IAQ) improvements. (2) Methods: this study examined the combined effect of ventilation type, airflow rates, and filtration on IAQ in five different classrooms. Experiments were conducted by releasing inert surrogate particles into the classrooms and measuring the concentrations in various locations of the room. (3) Results: we showed that while the distribution of particles in the space is a complex function of space geometry and air distribution configurations, the average decay rate of contaminants is proportional to the number of air changes per hour in the room. (4) Conclusions: rooms with a central HVAC system responded quicker to an internal source of contamination than rooms with only fan coil units. Furthermore, increasing the ventilation rate without improved filtration is an inefficient use of energy.
format article
author Ali Mohammadi Nafchi
Vincent Blouin
Nigel Kaye
Andrew Metcalf
Katie Van Valkinburgh
Ehsan Mousavi
author_facet Ali Mohammadi Nafchi
Vincent Blouin
Nigel Kaye
Andrew Metcalf
Katie Van Valkinburgh
Ehsan Mousavi
author_sort Ali Mohammadi Nafchi
title Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic
title_short Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic
title_full Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic
title_fullStr Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic
title_full_unstemmed Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic
title_sort room hvac influences on the removal of airborne particulate matter: implications for school reopening during the covid-19 pandemic
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/53310ebdd5d147b4a14f8ed6d48f1a8b
work_keys_str_mv AT alimohammadinafchi roomhvacinfluencesontheremovalofairborneparticulatematterimplicationsforschoolreopeningduringthecovid19pandemic
AT vincentblouin roomhvacinfluencesontheremovalofairborneparticulatematterimplicationsforschoolreopeningduringthecovid19pandemic
AT nigelkaye roomhvacinfluencesontheremovalofairborneparticulatematterimplicationsforschoolreopeningduringthecovid19pandemic
AT andrewmetcalf roomhvacinfluencesontheremovalofairborneparticulatematterimplicationsforschoolreopeningduringthecovid19pandemic
AT katievanvalkinburgh roomhvacinfluencesontheremovalofairborneparticulatematterimplicationsforschoolreopeningduringthecovid19pandemic
AT ehsanmousavi roomhvacinfluencesontheremovalofairborneparticulatematterimplicationsforschoolreopeningduringthecovid19pandemic
_version_ 1718412349210099712