The use of imbricated sutures in radioactive plaque brachytherapy surgery

Kaan Gündüz1, Jose S Pulido1, Peter D Yeakel2, Michael King3, Kelly L Classic1, Keith M Furutani21Department of Ophthalmology, 2Department of Radiation Oncology, 3Section of Media Support Services, Mayo Clinic, Rochester, MN, USAAbstract: This paper describes a new techniqu...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Kaan Gündüz, Jose S Pulido1, Peter D Yeakel, et al
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2010
Materias:
Acceso en línea:https://doaj.org/article/542d2909aec64cd0b2293594bf6749d9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:542d2909aec64cd0b2293594bf6749d9
record_format dspace
spelling oai:doaj.org-article:542d2909aec64cd0b2293594bf6749d92021-12-02T08:31:02ZThe use of imbricated sutures in radioactive plaque brachytherapy surgery1177-54671177-5483https://doaj.org/article/542d2909aec64cd0b2293594bf6749d92010-03-01T00:00:00Zhttp://www.dovepress.com/the-use-of-imbricated-sutures-in-radioactive-plaque-brachytherapy-surg-a4091https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Kaan Gündüz1, Jose S Pulido1, Peter D Yeakel2, Michael King3, Kelly L Classic1, Keith M Furutani21Department of Ophthalmology, 2Department of Radiation Oncology, 3Section of Media Support Services, Mayo Clinic, Rochester, MN, USAAbstract: This paper describes a new technique to suture the radioactive plaque to sclera. The radioactive plaque is conventionally sutured to the sclera using 5/0 nylon sutures. The imbricated suture technique involves using a 1/0 silk or 2/0 mersilene suture imbricated with the 5/0 nylon suture when the nylon suture is tied and cut. The imbricated suture technique allows easy identification of the plaque at removal and provides a surface that separates the 5/0 nylon from the surface of the eyelet platform, making suture cutting easier and safer. The radiation exposure times ranged from 9.1 minutes to 14 minutes (mean: 10.8 minutes) during plaque insertion and from 2.8 to 3.3 minutes (mean: 3.0 minutes) during plaque removal with the imbricated suture technique. This technique may decrease radiation exposure time and may prevent inadvertent scleral damage.Keywords: plaque radiotherapy, Iodine-125, Ruthenium-106, Collaborative Ocular Melanoma Study, choroidal melanoma, ciliary body melanoma, retinoblastoma, plaque placement, plaque removal, radiation exposure Kaan GündüzJose S Pulido1Peter D Yeakelet alDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2010, Iss default, Pp 159-161 (2010)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Kaan Gündüz
Jose S Pulido1
Peter D Yeakel
et al
The use of imbricated sutures in radioactive plaque brachytherapy surgery
description Kaan Gündüz1, Jose S Pulido1, Peter D Yeakel2, Michael King3, Kelly L Classic1, Keith M Furutani21Department of Ophthalmology, 2Department of Radiation Oncology, 3Section of Media Support Services, Mayo Clinic, Rochester, MN, USAAbstract: This paper describes a new technique to suture the radioactive plaque to sclera. The radioactive plaque is conventionally sutured to the sclera using 5/0 nylon sutures. The imbricated suture technique involves using a 1/0 silk or 2/0 mersilene suture imbricated with the 5/0 nylon suture when the nylon suture is tied and cut. The imbricated suture technique allows easy identification of the plaque at removal and provides a surface that separates the 5/0 nylon from the surface of the eyelet platform, making suture cutting easier and safer. The radiation exposure times ranged from 9.1 minutes to 14 minutes (mean: 10.8 minutes) during plaque insertion and from 2.8 to 3.3 minutes (mean: 3.0 minutes) during plaque removal with the imbricated suture technique. This technique may decrease radiation exposure time and may prevent inadvertent scleral damage.Keywords: plaque radiotherapy, Iodine-125, Ruthenium-106, Collaborative Ocular Melanoma Study, choroidal melanoma, ciliary body melanoma, retinoblastoma, plaque placement, plaque removal, radiation exposure
format article
author Kaan Gündüz
Jose S Pulido1
Peter D Yeakel
et al
author_facet Kaan Gündüz
Jose S Pulido1
Peter D Yeakel
et al
author_sort Kaan Gündüz
title The use of imbricated sutures in radioactive plaque brachytherapy surgery
title_short The use of imbricated sutures in radioactive plaque brachytherapy surgery
title_full The use of imbricated sutures in radioactive plaque brachytherapy surgery
title_fullStr The use of imbricated sutures in radioactive plaque brachytherapy surgery
title_full_unstemmed The use of imbricated sutures in radioactive plaque brachytherapy surgery
title_sort use of imbricated sutures in radioactive plaque brachytherapy surgery
publisher Dove Medical Press
publishDate 2010
url https://doaj.org/article/542d2909aec64cd0b2293594bf6749d9
work_keys_str_mv AT kaangampuumlndampuumlz theuseofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
AT josespulido1 theuseofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
AT peterdyeakel theuseofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
AT etal theuseofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
AT kaangampuumlndampuumlz useofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
AT josespulido1 useofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
AT peterdyeakel useofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
AT etal useofimbricatedsuturesinradioactiveplaquebrachytherapysurgery
_version_ 1718398482914476032