Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces

Abstract VOCs (volatile organic compounds) are increasingly wished to be used in diagnosis of diseases. They present strategic advantages, when compared to classical methods used, such as simplicity and current availability of performant non-invasive sample collection methods/systems. However, stand...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ileana Andreea Ratiu, Radik Mametov, Tomasz Ligor, Bogusław Buszewski
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/548711760f424381b4283b4a193789dc
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:548711760f424381b4283b4a193789dc
record_format dspace
spelling oai:doaj.org-article:548711760f424381b4283b4a193789dc2021-12-02T15:15:23ZMicro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces10.1038/s41598-021-98279-z2045-2322https://doaj.org/article/548711760f424381b4283b4a193789dc2021-09-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-98279-zhttps://doaj.org/toc/2045-2322Abstract VOCs (volatile organic compounds) are increasingly wished to be used in diagnosis of diseases. They present strategic advantages, when compared to classical methods used, such as simplicity and current availability of performant non-invasive sample collection methods/systems. However, standardized sampling methods are required in order to achieve reproducible results. In the current study we developed a method to be used for feces sampling using a Micro-Chamber/Thermal Extractor (µ-CTE). Design Expert software (with Box–Behnken design) was used to predict the solutions. Therefore, by using the simulation experimental plan that was further experimentally verified, extraction time of 19.6 min, at extraction temperature of 30.6 °C by using a flow rate of 48.7 mL/min provided the higher response. The developed method was validated by using correlation tests and Network analysis, which both proved the validity of the developed model.Ileana Andreea RatiuRadik MametovTomasz LigorBogusław BuszewskiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-13 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Ileana Andreea Ratiu
Radik Mametov
Tomasz Ligor
Bogusław Buszewski
Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces
description Abstract VOCs (volatile organic compounds) are increasingly wished to be used in diagnosis of diseases. They present strategic advantages, when compared to classical methods used, such as simplicity and current availability of performant non-invasive sample collection methods/systems. However, standardized sampling methods are required in order to achieve reproducible results. In the current study we developed a method to be used for feces sampling using a Micro-Chamber/Thermal Extractor (µ-CTE). Design Expert software (with Box–Behnken design) was used to predict the solutions. Therefore, by using the simulation experimental plan that was further experimentally verified, extraction time of 19.6 min, at extraction temperature of 30.6 °C by using a flow rate of 48.7 mL/min provided the higher response. The developed method was validated by using correlation tests and Network analysis, which both proved the validity of the developed model.
format article
author Ileana Andreea Ratiu
Radik Mametov
Tomasz Ligor
Bogusław Buszewski
author_facet Ileana Andreea Ratiu
Radik Mametov
Tomasz Ligor
Bogusław Buszewski
author_sort Ileana Andreea Ratiu
title Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces
title_short Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces
title_full Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces
title_fullStr Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces
title_full_unstemmed Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces
title_sort micro-chamber/thermal extractor (µ-cte) as a new sampling system for vocs emitted by feces
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/548711760f424381b4283b4a193789dc
work_keys_str_mv AT ileanaandreearatiu microchamberthermalextractorμcteasanewsamplingsystemforvocsemittedbyfeces
AT radikmametov microchamberthermalextractorμcteasanewsamplingsystemforvocsemittedbyfeces
AT tomaszligor microchamberthermalextractorμcteasanewsamplingsystemforvocsemittedbyfeces
AT bogusławbuszewski microchamberthermalextractorμcteasanewsamplingsystemforvocsemittedbyfeces
_version_ 1718387508069269504