Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas

Abstract To evaluate the diagnostic performance of magnetic resonance imaging (MRI) alone in comparison to positron emission tomography/ magnetic resonance imaging (PET/MRI) in patients with meningiomas. 57 patients with a total of 112 meningiomas of the brain were included. PET/MRI, including a ful...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Heike C. Einhellig, Eberhard Siebert, Hans-C. Bauknecht, Anna Tietze, Josefine Graef, Christian Furth, Daniel Schulze, Milena Miszczuk, Georg Bohner, Imke Schatka, Marcus R. Makowski
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/54d5ae60aeb24348a8db19dcabd8eb2a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:54d5ae60aeb24348a8db19dcabd8eb2a
record_format dspace
spelling oai:doaj.org-article:54d5ae60aeb24348a8db19dcabd8eb2a2021-12-02T16:55:34ZComparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas10.1038/s41598-021-87866-92045-2322https://doaj.org/article/54d5ae60aeb24348a8db19dcabd8eb2a2021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87866-9https://doaj.org/toc/2045-2322Abstract To evaluate the diagnostic performance of magnetic resonance imaging (MRI) alone in comparison to positron emission tomography/ magnetic resonance imaging (PET/MRI) in patients with meningiomas. 57 patients with a total of 112 meningiomas of the brain were included. PET/MRI, including a fully diagnostic contrast enhanced MRI and PET, were acquired. PET/MRI was used as reference standard. The size and location of meningiomas was recorded. Likelihood-ratio chi-square tests were used to calculate p-values within logistic regression in order to compare different models. A multi-level logistic regression was applied to comply the hierarchical data structure. Multi-level regression adjusts for clustering in data was performed. The majority (n = 103) of meningiomas could be identified based on standard MRI sequences compared to PET/MRI. MRI alone achieved a sensitivity of 95% (95% CI 0.78, 0.99) and specificity of 88% (95% CI 0.58, 0.98). Based on intensity of contrast medium uptake, 97 meningiomas could be diagnosed with intense uptake (93.75%). Sensitivity was lowest with 74% for meningiomas < 0.5 cm3, high with 95% for meningiomas > 2cm3 and highest with 100% for meningiomas 0.5–1.0 cm3. Petroclival meningiomas showed lowest sensitivity with 88% compared to sphenoidal meningiomas with 94% and orbital meningiomas with 100%. Specificity of meningioma diagnostic with MRI was high with 100% for sphenoidal and hemispherical-dural meningiomas and meningiomas with 0.5–1.0 and 1.0–2.0 cm3. Overall MRI enables reliable detection of meningiomas compared to PET/MRI. PET/MRI imaging offers highest sensitivity and specificity for small or difficult located meningiomas.Heike C. EinhelligEberhard SiebertHans-C. BauknechtAnna TietzeJosefine GraefChristian FurthDaniel SchulzeMilena MiszczukGeorg BohnerImke SchatkaMarcus R. MakowskiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Heike C. Einhellig
Eberhard Siebert
Hans-C. Bauknecht
Anna Tietze
Josefine Graef
Christian Furth
Daniel Schulze
Milena Miszczuk
Georg Bohner
Imke Schatka
Marcus R. Makowski
Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas
description Abstract To evaluate the diagnostic performance of magnetic resonance imaging (MRI) alone in comparison to positron emission tomography/ magnetic resonance imaging (PET/MRI) in patients with meningiomas. 57 patients with a total of 112 meningiomas of the brain were included. PET/MRI, including a fully diagnostic contrast enhanced MRI and PET, were acquired. PET/MRI was used as reference standard. The size and location of meningiomas was recorded. Likelihood-ratio chi-square tests were used to calculate p-values within logistic regression in order to compare different models. A multi-level logistic regression was applied to comply the hierarchical data structure. Multi-level regression adjusts for clustering in data was performed. The majority (n = 103) of meningiomas could be identified based on standard MRI sequences compared to PET/MRI. MRI alone achieved a sensitivity of 95% (95% CI 0.78, 0.99) and specificity of 88% (95% CI 0.58, 0.98). Based on intensity of contrast medium uptake, 97 meningiomas could be diagnosed with intense uptake (93.75%). Sensitivity was lowest with 74% for meningiomas < 0.5 cm3, high with 95% for meningiomas > 2cm3 and highest with 100% for meningiomas 0.5–1.0 cm3. Petroclival meningiomas showed lowest sensitivity with 88% compared to sphenoidal meningiomas with 94% and orbital meningiomas with 100%. Specificity of meningioma diagnostic with MRI was high with 100% for sphenoidal and hemispherical-dural meningiomas and meningiomas with 0.5–1.0 and 1.0–2.0 cm3. Overall MRI enables reliable detection of meningiomas compared to PET/MRI. PET/MRI imaging offers highest sensitivity and specificity for small or difficult located meningiomas.
format article
author Heike C. Einhellig
Eberhard Siebert
Hans-C. Bauknecht
Anna Tietze
Josefine Graef
Christian Furth
Daniel Schulze
Milena Miszczuk
Georg Bohner
Imke Schatka
Marcus R. Makowski
author_facet Heike C. Einhellig
Eberhard Siebert
Hans-C. Bauknecht
Anna Tietze
Josefine Graef
Christian Furth
Daniel Schulze
Milena Miszczuk
Georg Bohner
Imke Schatka
Marcus R. Makowski
author_sort Heike C. Einhellig
title Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas
title_short Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas
title_full Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas
title_fullStr Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas
title_full_unstemmed Comparison of diagnostic value of 68 Ga-DOTATOC PET/MRI and standalone MRI for the detection of intracranial meningiomas
title_sort comparison of diagnostic value of 68 ga-dotatoc pet/mri and standalone mri for the detection of intracranial meningiomas
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/54d5ae60aeb24348a8db19dcabd8eb2a
work_keys_str_mv AT heikeceinhellig comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT eberhardsiebert comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT hanscbauknecht comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT annatietze comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT josefinegraef comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT christianfurth comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT danielschulze comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT milenamiszczuk comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT georgbohner comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT imkeschatka comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
AT marcusrmakowski comparisonofdiagnosticvalueof68gadotatocpetmriandstandalonemriforthedetectionofintracranialmeningiomas
_version_ 1718382800237756416