Optimal Control Method of Variable Air Volume Terminal Unit System
This study reviewed the existing studies on the types of variable air volume (VAV) terminal units, control and operation methods, prediction models, and sensor calibration methods. As a result of analyzing the existing research trends on the system type, characteristics, and control method of VAV te...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/54e38e985fb446cfa4df523f7bae5222 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:54e38e985fb446cfa4df523f7bae5222 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:54e38e985fb446cfa4df523f7bae52222021-11-25T17:26:20ZOptimal Control Method of Variable Air Volume Terminal Unit System10.3390/en142275271996-1073https://doaj.org/article/54e38e985fb446cfa4df523f7bae52222021-11-01T00:00:00Zhttps://www.mdpi.com/1996-1073/14/22/7527https://doaj.org/toc/1996-1073This study reviewed the existing studies on the types of variable air volume (VAV) terminal units, control and operation methods, prediction models, and sensor calibration methods. As a result of analyzing the existing research trends on the system type, characteristics, and control method of VAV terminal units studies such as theoretical verification and energy simulation were conducted to improve the existing control methods, reset the set value using a mathematical model, and add a monitoring sensor for the application of control methods. The mathematical model used in the study of VAV terminal unit control methods was used to derive set values for minimum air volume, supply temperature, ventilation requirements, and indoor comfort. The mathematical model has a limitation in collecting input information for professional knowledge and model development, and development of a building environment prediction model using a black box model is being studied. The VAV terminal unit system uses a sensor to control the device, and when an error occurs in the sensor, indoor comfort problems and energy waste occur. To solve this problem, sensor calibration techniques have been developed using statistical models, mathematical models, and Bayesian statistical models. The possibility of developing a method for calibrating the variable air volume terminal unit sensor using the prediction model was confirmed. In conclusion, the VAV terminal unit system is one of the most energy efficient systems. The energy saving potential of current VAV systems can still be improved through control methods, the use of predictive models, and sensor calibration methods.Hyo-Jun KimYoung-Hum ChoMDPI AGarticlevariable air volume systemterminal unitoptimal controlprediction modelsensor calibrationTechnologyTENEnergies, Vol 14, Iss 7527, p 7527 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
variable air volume system terminal unit optimal control prediction model sensor calibration Technology T |
spellingShingle |
variable air volume system terminal unit optimal control prediction model sensor calibration Technology T Hyo-Jun Kim Young-Hum Cho Optimal Control Method of Variable Air Volume Terminal Unit System |
description |
This study reviewed the existing studies on the types of variable air volume (VAV) terminal units, control and operation methods, prediction models, and sensor calibration methods. As a result of analyzing the existing research trends on the system type, characteristics, and control method of VAV terminal units studies such as theoretical verification and energy simulation were conducted to improve the existing control methods, reset the set value using a mathematical model, and add a monitoring sensor for the application of control methods. The mathematical model used in the study of VAV terminal unit control methods was used to derive set values for minimum air volume, supply temperature, ventilation requirements, and indoor comfort. The mathematical model has a limitation in collecting input information for professional knowledge and model development, and development of a building environment prediction model using a black box model is being studied. The VAV terminal unit system uses a sensor to control the device, and when an error occurs in the sensor, indoor comfort problems and energy waste occur. To solve this problem, sensor calibration techniques have been developed using statistical models, mathematical models, and Bayesian statistical models. The possibility of developing a method for calibrating the variable air volume terminal unit sensor using the prediction model was confirmed. In conclusion, the VAV terminal unit system is one of the most energy efficient systems. The energy saving potential of current VAV systems can still be improved through control methods, the use of predictive models, and sensor calibration methods. |
format |
article |
author |
Hyo-Jun Kim Young-Hum Cho |
author_facet |
Hyo-Jun Kim Young-Hum Cho |
author_sort |
Hyo-Jun Kim |
title |
Optimal Control Method of Variable Air Volume Terminal Unit System |
title_short |
Optimal Control Method of Variable Air Volume Terminal Unit System |
title_full |
Optimal Control Method of Variable Air Volume Terminal Unit System |
title_fullStr |
Optimal Control Method of Variable Air Volume Terminal Unit System |
title_full_unstemmed |
Optimal Control Method of Variable Air Volume Terminal Unit System |
title_sort |
optimal control method of variable air volume terminal unit system |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/54e38e985fb446cfa4df523f7bae5222 |
work_keys_str_mv |
AT hyojunkim optimalcontrolmethodofvariableairvolumeterminalunitsystem AT younghumcho optimalcontrolmethodofvariableairvolumeterminalunitsystem |
_version_ |
1718412350012260352 |