Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE

Abstract Similar to sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE), T2-weighted fast field echo (FFE) also has a black blood effect and a high imaging efficiency. The purpose of this study was to optimize 3D_T2_FFE and compare it with 3D_T2_SPAC...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ang Yang, Xue Hong Xiao, Zhi Long Wang, Yong Xin Zhang, Ke Yi Wang
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/555b93aaeb33496abc41645e02f97143
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:555b93aaeb33496abc41645e02f97143
record_format dspace
spelling oai:doaj.org-article:555b93aaeb33496abc41645e02f971432021-12-02T13:57:25ZCarotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE10.1038/s41598-021-81309-12045-2322https://doaj.org/article/555b93aaeb33496abc41645e02f971432021-01-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-81309-1https://doaj.org/toc/2045-2322Abstract Similar to sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE), T2-weighted fast field echo (FFE) also has a black blood effect and a high imaging efficiency. The purpose of this study was to optimize 3D_T2_FFE and compare it with 3D_T2_SPACE for carotid imaging. The scanning parameter of 3D_T2_FFE was optimized for the imaging of the carotid wall. Twenty healthy volunteers and 10 patients with carotid plaque underwent cervical 3D_T2_FFE and 3D_T2_SPACE examinations. The signal-to-noise ratios of the carotid wall (SNRwall) and lumen (SNRlumen), and the contrast-to-noise ratios between the wall and lumen (CNRwall_lumen) were compared. The incidence of the residual flow signal at the carotid bifurcation and the grades of flow voids in the cerebellopontine angle region in the two sequences were also compared. The reproducibility of the two sequences was tested. No significant difference was observed between the two sequences in terms of the SNRwall of healthy individuals and patients (P = 0.132 and 0.102, respectively). The SNRlumen in the 3D_T2_FFE images was lower than that in the 3D_T2_SPACE images. No significant difference was observed between the two sequences in terms of the CNRwall-lumen. The incidence of the residual flow signal at the carotid bifurcation in 3D_T2_FFE was significantly lower than that in 3D_T2_SPACE. The grades of flow suppression in the cerebellopontine angle region in 3D_T2_SPACE was lower than that in 3D_T2_FFE. Both sequences showed excellent inter-and intra-observer reproducibility. Compared to 3D_T2_SPACE, 3D_T2_FFE showed stronger flow suppression while maintaining good imaging quality, which can be used as an alternative tool for carotid imaging.Ang YangXue Hong XiaoZhi Long WangYong Xin ZhangKe Yi WangNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-8 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Ang Yang
Xue Hong Xiao
Zhi Long Wang
Yong Xin Zhang
Ke Yi Wang
Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE
description Abstract Similar to sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE), T2-weighted fast field echo (FFE) also has a black blood effect and a high imaging efficiency. The purpose of this study was to optimize 3D_T2_FFE and compare it with 3D_T2_SPACE for carotid imaging. The scanning parameter of 3D_T2_FFE was optimized for the imaging of the carotid wall. Twenty healthy volunteers and 10 patients with carotid plaque underwent cervical 3D_T2_FFE and 3D_T2_SPACE examinations. The signal-to-noise ratios of the carotid wall (SNRwall) and lumen (SNRlumen), and the contrast-to-noise ratios between the wall and lumen (CNRwall_lumen) were compared. The incidence of the residual flow signal at the carotid bifurcation and the grades of flow voids in the cerebellopontine angle region in the two sequences were also compared. The reproducibility of the two sequences was tested. No significant difference was observed between the two sequences in terms of the SNRwall of healthy individuals and patients (P = 0.132 and 0.102, respectively). The SNRlumen in the 3D_T2_FFE images was lower than that in the 3D_T2_SPACE images. No significant difference was observed between the two sequences in terms of the CNRwall-lumen. The incidence of the residual flow signal at the carotid bifurcation in 3D_T2_FFE was significantly lower than that in 3D_T2_SPACE. The grades of flow suppression in the cerebellopontine angle region in 3D_T2_SPACE was lower than that in 3D_T2_FFE. Both sequences showed excellent inter-and intra-observer reproducibility. Compared to 3D_T2_SPACE, 3D_T2_FFE showed stronger flow suppression while maintaining good imaging quality, which can be used as an alternative tool for carotid imaging.
format article
author Ang Yang
Xue Hong Xiao
Zhi Long Wang
Yong Xin Zhang
Ke Yi Wang
author_facet Ang Yang
Xue Hong Xiao
Zhi Long Wang
Yong Xin Zhang
Ke Yi Wang
author_sort Ang Yang
title Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE
title_short Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE
title_full Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE
title_fullStr Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE
title_full_unstemmed Carotid wall imaging with 3D_T2_FFE: sequence parameter optimization and comparison with 3D_T2_SPACE
title_sort carotid wall imaging with 3d_t2_ffe: sequence parameter optimization and comparison with 3d_t2_space
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/555b93aaeb33496abc41645e02f97143
work_keys_str_mv AT angyang carotidwallimagingwith3dt2ffesequenceparameteroptimizationandcomparisonwith3dt2space
AT xuehongxiao carotidwallimagingwith3dt2ffesequenceparameteroptimizationandcomparisonwith3dt2space
AT zhilongwang carotidwallimagingwith3dt2ffesequenceparameteroptimizationandcomparisonwith3dt2space
AT yongxinzhang carotidwallimagingwith3dt2ffesequenceparameteroptimizationandcomparisonwith3dt2space
AT keyiwang carotidwallimagingwith3dt2ffesequenceparameteroptimizationandcomparisonwith3dt2space
_version_ 1718392321896087552