OPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES

Purpose. The purpose of the paper is to determine the basic electrical characteristics and to develop a calculation method and algorithm for optimizing the design parameters of autotransformers intended for use in a melting ice scheme with a non-inductive circuit on 6-10 kV overhead power lines. Met...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: O. P. Lazurenko, A. N. Moroz, S. O. Tymchuk, O. O. Miroshnyk, O. A. Savchenko
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2019
Materias:
Acceso en línea:https://doaj.org/article/5633d1d9723547dd892cc185193ff5bb
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:5633d1d9723547dd892cc185193ff5bb
record_format dspace
spelling oai:doaj.org-article:5633d1d9723547dd892cc185193ff5bb2021-12-02T14:32:12ZOPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES10.20998/2074-272X.2019.3.102074-272X2309-3404https://doaj.org/article/5633d1d9723547dd892cc185193ff5bb2019-06-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2019.3.10/171142https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Purpose. The purpose of the paper is to determine the basic electrical characteristics and to develop a calculation method and algorithm for optimizing the design parameters of autotransformers intended for use in a melting ice scheme with a non-inductive circuit on 6-10 kV overhead power lines. Methodology. The development of the technical and economic model and the method for calculation of the design parameters of the autotransformer for melting ice is performed on the basis of a systematic approach. Optimization of structural characteristics of autotransformers is carried out using a combined algorithm based on the spatial grid method, adapted to the case of a mixed space of discrete and continuous independent variables, and the specifics of the technical and economic model of the autotransformer. The proposed combined optimization algorithm is implemented in the Delphi environment. Results. Based on the required specific melting power, the main electrical characteristics of autotransformers intended for use in the melting ice scheme with a non-inductive circuit on 6-10 kV overhead lines, which were the basis for optimizing their design parameters, have been calculated. The technical and economical model of autotransformer for melting ice, which is defined by nine independent variables and describes its cost and technical parameters, is developed. On the basis of the obtained electrical characteristics, optimization of the design parameters of a series of autotransformers is carried out, which includes three standard sizes, differing in maximum length of the transmission line. Originality. A method of calculation of structural parameters of autotransformers for ice melting is proposed, the peculiarity of which is the use of the criterion of the minimum of the cost of the active part and taking into account the conditioned by the circuit of connection of the autotransformers the technical restrictions of errors on the value and angle of secondary current, which are important from the point of view of ensuring the permissible deviation of the specific power of melting ice. Practical value. Optimal correlations of geometrical sizes and electromagnetic loads of autotransformers for ice melting, their cost indicators, as well as the main design characteristics of the magnetic circuit and windings are established. Results of design calculation of autotransformers are sufficient for introduction of their serial production in industrial conditions. O. P. LazurenkoA. N. MorozS. O. TymchukO. O. MiroshnykO. A. SavchenkoNational Technical University "Kharkiv Polytechnic Institute"articleoverhead power linemelting of iceautotransformer for melting of icetechnical and economic modeloptimization of design parametersElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 3, Pp 59-66 (2019)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic overhead power line
melting of ice
autotransformer for melting of ice
technical and economic model
optimization of design parameters
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle overhead power line
melting of ice
autotransformer for melting of ice
technical and economic model
optimization of design parameters
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
O. P. Lazurenko
A. N. Moroz
S. O. Tymchuk
O. O. Miroshnyk
O. A. Savchenko
OPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES
description Purpose. The purpose of the paper is to determine the basic electrical characteristics and to develop a calculation method and algorithm for optimizing the design parameters of autotransformers intended for use in a melting ice scheme with a non-inductive circuit on 6-10 kV overhead power lines. Methodology. The development of the technical and economic model and the method for calculation of the design parameters of the autotransformer for melting ice is performed on the basis of a systematic approach. Optimization of structural characteristics of autotransformers is carried out using a combined algorithm based on the spatial grid method, adapted to the case of a mixed space of discrete and continuous independent variables, and the specifics of the technical and economic model of the autotransformer. The proposed combined optimization algorithm is implemented in the Delphi environment. Results. Based on the required specific melting power, the main electrical characteristics of autotransformers intended for use in the melting ice scheme with a non-inductive circuit on 6-10 kV overhead lines, which were the basis for optimizing their design parameters, have been calculated. The technical and economical model of autotransformer for melting ice, which is defined by nine independent variables and describes its cost and technical parameters, is developed. On the basis of the obtained electrical characteristics, optimization of the design parameters of a series of autotransformers is carried out, which includes three standard sizes, differing in maximum length of the transmission line. Originality. A method of calculation of structural parameters of autotransformers for ice melting is proposed, the peculiarity of which is the use of the criterion of the minimum of the cost of the active part and taking into account the conditioned by the circuit of connection of the autotransformers the technical restrictions of errors on the value and angle of secondary current, which are important from the point of view of ensuring the permissible deviation of the specific power of melting ice. Practical value. Optimal correlations of geometrical sizes and electromagnetic loads of autotransformers for ice melting, their cost indicators, as well as the main design characteristics of the magnetic circuit and windings are established. Results of design calculation of autotransformers are sufficient for introduction of their serial production in industrial conditions.
format article
author O. P. Lazurenko
A. N. Moroz
S. O. Tymchuk
O. O. Miroshnyk
O. A. Savchenko
author_facet O. P. Lazurenko
A. N. Moroz
S. O. Tymchuk
O. O. Miroshnyk
O. A. Savchenko
author_sort O. P. Lazurenko
title OPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES
title_short OPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES
title_full OPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES
title_fullStr OPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES
title_full_unstemmed OPTIMIZATION OF DESIGN PARAMETERS OF AUTOTRANSFORMERS IN ICE MELTING SCHEME WITH NON-INDUCTIVE CIRCUIT ON 6-10 KV OVERHEAD POWER LINES
title_sort optimization of design parameters of autotransformers in ice melting scheme with non-inductive circuit on 6-10 kv overhead power lines
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2019
url https://doaj.org/article/5633d1d9723547dd892cc185193ff5bb
work_keys_str_mv AT oplazurenko optimizationofdesignparametersofautotransformersinicemeltingschemewithnoninductivecircuiton610kvoverheadpowerlines
AT anmoroz optimizationofdesignparametersofautotransformersinicemeltingschemewithnoninductivecircuiton610kvoverheadpowerlines
AT sotymchuk optimizationofdesignparametersofautotransformersinicemeltingschemewithnoninductivecircuiton610kvoverheadpowerlines
AT oomiroshnyk optimizationofdesignparametersofautotransformersinicemeltingschemewithnoninductivecircuiton610kvoverheadpowerlines
AT oasavchenko optimizationofdesignparametersofautotransformersinicemeltingschemewithnoninductivecircuiton610kvoverheadpowerlines
_version_ 1718391191596171264