A Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications

Joint applications of virtual reality (VR) systems and electroencephalography (EEG) offer numerous new possibilities ranging from behavioral science to therapy. VR systems allow for highly controlled experimental environments, while EEG offers a non-invasive window to brain activity with a milliseco...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Desirée Weber, Stephan Hertweck, Hisham Alwanni, Lukas D. J. Fiederer, Xi Wang, Fabian Unruh, Martin Fischbach, Marc Erich Latoschik, Tonio Ball
Formato: article
Lenguaje:EN
Publicado: Frontiers Media S.A. 2021
Materias:
EEG
Acceso en línea:https://doaj.org/article/57387ccc79974f9dad1a1798a5609038
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:57387ccc79974f9dad1a1798a5609038
record_format dspace
spelling oai:doaj.org-article:57387ccc79974f9dad1a1798a56090382021-11-22T05:06:09ZA Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications1662-453X10.3389/fnins.2021.733673https://doaj.org/article/57387ccc79974f9dad1a1798a56090382021-11-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fnins.2021.733673/fullhttps://doaj.org/toc/1662-453XJoint applications of virtual reality (VR) systems and electroencephalography (EEG) offer numerous new possibilities ranging from behavioral science to therapy. VR systems allow for highly controlled experimental environments, while EEG offers a non-invasive window to brain activity with a millisecond-ranged temporal resolution. However, EEG measurements are highly susceptible to electromagnetic (EM) noise and the influence of EM noise of head-mounted-displays (HMDs) on EEG signal quality has not been conclusively investigated. In this paper, we propose a structured approach to test HMDs for EM noise potentially harmful to EEG measures. The approach verifies the impact of HMDs on the frequency- and time-domain of the EEG signal recorded in healthy subjects. The verification task includes a comparison of conditions with and without an HMD during (i) an eyes-open vs. eyes-closed task, and (ii) with respect to the sensory- evoked brain activity. The approach is developed and tested to derive potential effects of two commercial HMDs, the Oculus Rift and the HTC Vive Pro, on the quality of 64-channel EEG measurements. The results show that the HMDs consistently introduce artifacts, especially at the line hum of 50 Hz and the HMD refresh rate of 90 Hz, respectively, and their harmonics. The frequency range that is typically most important in non-invasive EEG research and applications (<50 Hz) however, remained largely unaffected. Hence, our findings demonstrate that high-quality EEG recordings, at least in the frequency range up to 50 Hz, can be obtained with the two tested HMDs. However, the number of commercially available HMDs is constantly rising. We strongly suggest to thoroughly test such devices upfront since each HMD will most likely have its own EM footprint and this article provides a structured approach to implement such tests with arbitrary devices.Desirée WeberStephan HertweckHisham AlwanniLukas D. J. FiedererXi WangFabian UnruhMartin FischbachMarc Erich LatoschikTonio BallFrontiers Media S.A.articleEEGhuman computer interactionvirtual realityalpha rhythmSEPsNeurosciences. Biological psychiatry. NeuropsychiatryRC321-571ENFrontiers in Neuroscience, Vol 15 (2021)
institution DOAJ
collection DOAJ
language EN
topic EEG
human computer interaction
virtual reality
alpha rhythm
SEPs
Neurosciences. Biological psychiatry. Neuropsychiatry
RC321-571
spellingShingle EEG
human computer interaction
virtual reality
alpha rhythm
SEPs
Neurosciences. Biological psychiatry. Neuropsychiatry
RC321-571
Desirée Weber
Stephan Hertweck
Hisham Alwanni
Lukas D. J. Fiederer
Xi Wang
Fabian Unruh
Martin Fischbach
Marc Erich Latoschik
Tonio Ball
A Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications
description Joint applications of virtual reality (VR) systems and electroencephalography (EEG) offer numerous new possibilities ranging from behavioral science to therapy. VR systems allow for highly controlled experimental environments, while EEG offers a non-invasive window to brain activity with a millisecond-ranged temporal resolution. However, EEG measurements are highly susceptible to electromagnetic (EM) noise and the influence of EM noise of head-mounted-displays (HMDs) on EEG signal quality has not been conclusively investigated. In this paper, we propose a structured approach to test HMDs for EM noise potentially harmful to EEG measures. The approach verifies the impact of HMDs on the frequency- and time-domain of the EEG signal recorded in healthy subjects. The verification task includes a comparison of conditions with and without an HMD during (i) an eyes-open vs. eyes-closed task, and (ii) with respect to the sensory- evoked brain activity. The approach is developed and tested to derive potential effects of two commercial HMDs, the Oculus Rift and the HTC Vive Pro, on the quality of 64-channel EEG measurements. The results show that the HMDs consistently introduce artifacts, especially at the line hum of 50 Hz and the HMD refresh rate of 90 Hz, respectively, and their harmonics. The frequency range that is typically most important in non-invasive EEG research and applications (<50 Hz) however, remained largely unaffected. Hence, our findings demonstrate that high-quality EEG recordings, at least in the frequency range up to 50 Hz, can be obtained with the two tested HMDs. However, the number of commercially available HMDs is constantly rising. We strongly suggest to thoroughly test such devices upfront since each HMD will most likely have its own EM footprint and this article provides a structured approach to implement such tests with arbitrary devices.
format article
author Desirée Weber
Stephan Hertweck
Hisham Alwanni
Lukas D. J. Fiederer
Xi Wang
Fabian Unruh
Martin Fischbach
Marc Erich Latoschik
Tonio Ball
author_facet Desirée Weber
Stephan Hertweck
Hisham Alwanni
Lukas D. J. Fiederer
Xi Wang
Fabian Unruh
Martin Fischbach
Marc Erich Latoschik
Tonio Ball
author_sort Desirée Weber
title A Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications
title_short A Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications
title_full A Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications
title_fullStr A Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications
title_full_unstemmed A Structured Approach to Test the Signal Quality of Electroencephalography Measurements During Use of Head-Mounted Displays for Virtual Reality Applications
title_sort structured approach to test the signal quality of electroencephalography measurements during use of head-mounted displays for virtual reality applications
publisher Frontiers Media S.A.
publishDate 2021
url https://doaj.org/article/57387ccc79974f9dad1a1798a5609038
work_keys_str_mv AT desireeweber astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT stephanhertweck astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT hishamalwanni astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT lukasdjfiederer astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT xiwang astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT fabianunruh astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT martinfischbach astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT marcerichlatoschik astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT tonioball astructuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT desireeweber structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT stephanhertweck structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT hishamalwanni structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT lukasdjfiederer structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT xiwang structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT fabianunruh structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT martinfischbach structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT marcerichlatoschik structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
AT tonioball structuredapproachtotestthesignalqualityofelectroencephalographymeasurementsduringuseofheadmounteddisplaysforvirtualrealityapplications
_version_ 1718418160845062144