Implantable collamer lens with central hole: 3-year follow-up
Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://doaj.org/article/5838d0a14bf34a818b741391e187529f |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:5838d0a14bf34a818b741391e187529f |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:5838d0a14bf34a818b741391e187529f2021-12-02T05:50:22ZImplantable collamer lens with central hole: 3-year follow-up1177-5483https://doaj.org/article/5838d0a14bf34a818b741391e187529f2018-10-01T00:00:00Zhttps://www.dovepress.com/implantable-collamer-lens-with-central-hole-3-year-follow-up-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of the V4c ICL. The refraction, uncorrected distance visual acuity, best-corrected distance visual acuity, IOP, endothelial cell count, vault, and adverse effects were evaluated every 12 months during the whole follow-up.Results: The mean spherical equivalent dropped from -8.30±2.98 D preoperatively to -0.37±0.47 D at 36 months post-surgery, with 91.8% eyes being within ±1.00 D of emmetropia. With respect to the astigmatic components J0 and J45, 98.4% and 99.5% of eyes, respectively, were within ±0.50 D of the desired refraction. At 36 months, 78.8% of eyes had no change in the Snellen lines of best-corrected distance visual acuity, while 8.7% gained one line and 6.5% gained two or more lines; mean safety and efficacy indexes were 1.03 and 0.90, respectively. Mean endothelial cell count was 2,742±340 cells/mm2 before and 2,663±366 cells/mm2 at 36 months post-surgery. Mean IOP reduced from 13.7±1.9 mmHg preoperatively to 12.8±1.7 mmHg at 36 months post-surgery. Mean vault varied from 409±196 µm at 12 months to 349±165 µm at 36 months.Conclusion: The visual and refractive outcomes were very good and highly stable throughout the follow-up period, indicating that this ICL model may be predictable, stable, safe, and effective to correct myopia in the long term. Keywords: phakic intraocular lens, implantable collamer lens, Visian ICL, long-term evaluationFernández-Vega-Cueto LLisa CEsteve-Taboada JJMontés-Micó RAlfonso JFDove Medical PressarticlePhakic intraocular lensImplantable Collamer LensVisian ICLlong-term evaluationOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 2015-2029 (2018) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Phakic intraocular lens Implantable Collamer Lens Visian ICL long-term evaluation Ophthalmology RE1-994 |
spellingShingle |
Phakic intraocular lens Implantable Collamer Lens Visian ICL long-term evaluation Ophthalmology RE1-994 Fernández-Vega-Cueto L Lisa C Esteve-Taboada JJ Montés-Micó R Alfonso JF Implantable collamer lens with central hole: 3-year follow-up |
description |
Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of the V4c ICL. The refraction, uncorrected distance visual acuity, best-corrected distance visual acuity, IOP, endothelial cell count, vault, and adverse effects were evaluated every 12 months during the whole follow-up.Results: The mean spherical equivalent dropped from -8.30±2.98 D preoperatively to -0.37±0.47 D at 36 months post-surgery, with 91.8% eyes being within ±1.00 D of emmetropia. With respect to the astigmatic components J0 and J45, 98.4% and 99.5% of eyes, respectively, were within ±0.50 D of the desired refraction. At 36 months, 78.8% of eyes had no change in the Snellen lines of best-corrected distance visual acuity, while 8.7% gained one line and 6.5% gained two or more lines; mean safety and efficacy indexes were 1.03 and 0.90, respectively. Mean endothelial cell count was 2,742±340 cells/mm2 before and 2,663±366 cells/mm2 at 36 months post-surgery. Mean IOP reduced from 13.7±1.9 mmHg preoperatively to 12.8±1.7 mmHg at 36 months post-surgery. Mean vault varied from 409±196 µm at 12 months to 349±165 µm at 36 months.Conclusion: The visual and refractive outcomes were very good and highly stable throughout the follow-up period, indicating that this ICL model may be predictable, stable, safe, and effective to correct myopia in the long term. Keywords: phakic intraocular lens, implantable collamer lens, Visian ICL, long-term evaluation |
format |
article |
author |
Fernández-Vega-Cueto L Lisa C Esteve-Taboada JJ Montés-Micó R Alfonso JF |
author_facet |
Fernández-Vega-Cueto L Lisa C Esteve-Taboada JJ Montés-Micó R Alfonso JF |
author_sort |
Fernández-Vega-Cueto L |
title |
Implantable collamer lens with central hole: 3-year follow-up |
title_short |
Implantable collamer lens with central hole: 3-year follow-up |
title_full |
Implantable collamer lens with central hole: 3-year follow-up |
title_fullStr |
Implantable collamer lens with central hole: 3-year follow-up |
title_full_unstemmed |
Implantable collamer lens with central hole: 3-year follow-up |
title_sort |
implantable collamer lens with central hole: 3-year follow-up |
publisher |
Dove Medical Press |
publishDate |
2018 |
url |
https://doaj.org/article/5838d0a14bf34a818b741391e187529f |
work_keys_str_mv |
AT fernandezvegacuetol implantablecollamerlenswithcentralhole3yearfollowup AT lisac implantablecollamerlenswithcentralhole3yearfollowup AT estevetaboadajj implantablecollamerlenswithcentralhole3yearfollowup AT montesmicor implantablecollamerlenswithcentralhole3yearfollowup AT alfonsojf implantablecollamerlenswithcentralhole3yearfollowup |
_version_ |
1718400230137790464 |