The diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia
Purpose: Septic thrombosis often complicates Staphylococcus aureus bacteremia (SAB) in patients with a central venous catheter. Currently there is no reference standard for diagnosis. We describe the diagnostic value of [18F]FDG-PET/CT imaging in a patient cohort and the potential contribution of qu...
Guardado en:
Autores principales: | , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/58e3b6e5e5284d1d9cf1313bd4d44b47 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:58e3b6e5e5284d1d9cf1313bd4d44b47 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:58e3b6e5e5284d1d9cf1313bd4d44b472021-11-14T04:29:21ZThe diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia0753-332210.1016/j.biopha.2021.112296https://doaj.org/article/58e3b6e5e5284d1d9cf1313bd4d44b472021-12-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S0753332221010805https://doaj.org/toc/0753-3322Purpose: Septic thrombosis often complicates Staphylococcus aureus bacteremia (SAB) in patients with a central venous catheter. Currently there is no reference standard for diagnosis. We describe the diagnostic value of [18F]FDG-PET/CT imaging in a patient cohort and the potential contribution of quantitative measurements in detecting septic thrombosis. Methods: We selected patients with catheter-related SAB from our institutional database (2013–2020). The contribution of [18F]FDG-PET/CT on clinical diagnosis of septic thrombosis was evaluated. Standardized Uptake Values (SUV) were measured and compared with a composite reference standard (clinical signs, initial [18F]FDG-PET/CT result, Multidisciplinary Team (MDT) meeting outcome) to identify a cut-off value for detecting septic thrombosis. Results: We identified 93 patients with a catheter-related SAB. Quantitative measurements were possible for 43/56 patients in whom a [18F]FDG-PET/CT scan was performed. Septic thrombosis was clinically diagnosed in 30% (13/43) of the cases. In 85% of these cases, significant [18F]FDG-PET/CT uptake at the site of the thrombus was the deciding factor for diagnosis of septic thrombosis during the MDT meeting. All mean SUV’s of thrombotic lesions were higher in patients with clinically proven septic thrombosis compared to patients in whom this diagnosis was rejected (p < 0.001). A SUVpeak thrombus/SUVmean blood ratio of 1.6 (AUC-ROC value 0.982) as cut-off to differentiate between septic thrombosis and non-septic thrombosis had a sensitivity of 92% (95% CI 64–100) and specificity of 89% (95% CI 65–99). An algorithm was designed to guide diagnosis of septic thrombosis. Conclusion: Quantitative [18F]FDG-PET/CT-derived parameters seem helpful to differentiate between septic and non-septic thrombosis in patients with catheter-related SAB.Michelle GompelmanRenée TuinteErik AarntzenIlse KouijzerEline van LeerdamMarvin BerrevoetsJaap Ten OeverChantal Bleeker-RoversGeert WantenElsevierarticleseptic thrombosisStaphylococcus aureus bacteremiacatheter-related bloodstream infections[18F]FDG-PET/CTTherapeutics. PharmacologyRM1-950ENBiomedicine & Pharmacotherapy, Vol 144, Iss , Pp 112296- (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
septic thrombosis Staphylococcus aureus bacteremia catheter-related bloodstream infections [18F]FDG-PET/CT Therapeutics. Pharmacology RM1-950 |
spellingShingle |
septic thrombosis Staphylococcus aureus bacteremia catheter-related bloodstream infections [18F]FDG-PET/CT Therapeutics. Pharmacology RM1-950 Michelle Gompelman Renée Tuinte Erik Aarntzen Ilse Kouijzer Eline van Leerdam Marvin Berrevoets Jaap Ten Oever Chantal Bleeker-Rovers Geert Wanten The diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia |
description |
Purpose: Septic thrombosis often complicates Staphylococcus aureus bacteremia (SAB) in patients with a central venous catheter. Currently there is no reference standard for diagnosis. We describe the diagnostic value of [18F]FDG-PET/CT imaging in a patient cohort and the potential contribution of quantitative measurements in detecting septic thrombosis. Methods: We selected patients with catheter-related SAB from our institutional database (2013–2020). The contribution of [18F]FDG-PET/CT on clinical diagnosis of septic thrombosis was evaluated. Standardized Uptake Values (SUV) were measured and compared with a composite reference standard (clinical signs, initial [18F]FDG-PET/CT result, Multidisciplinary Team (MDT) meeting outcome) to identify a cut-off value for detecting septic thrombosis. Results: We identified 93 patients with a catheter-related SAB. Quantitative measurements were possible for 43/56 patients in whom a [18F]FDG-PET/CT scan was performed. Septic thrombosis was clinically diagnosed in 30% (13/43) of the cases. In 85% of these cases, significant [18F]FDG-PET/CT uptake at the site of the thrombus was the deciding factor for diagnosis of septic thrombosis during the MDT meeting. All mean SUV’s of thrombotic lesions were higher in patients with clinically proven septic thrombosis compared to patients in whom this diagnosis was rejected (p < 0.001). A SUVpeak thrombus/SUVmean blood ratio of 1.6 (AUC-ROC value 0.982) as cut-off to differentiate between septic thrombosis and non-septic thrombosis had a sensitivity of 92% (95% CI 64–100) and specificity of 89% (95% CI 65–99). An algorithm was designed to guide diagnosis of septic thrombosis. Conclusion: Quantitative [18F]FDG-PET/CT-derived parameters seem helpful to differentiate between septic and non-septic thrombosis in patients with catheter-related SAB. |
format |
article |
author |
Michelle Gompelman Renée Tuinte Erik Aarntzen Ilse Kouijzer Eline van Leerdam Marvin Berrevoets Jaap Ten Oever Chantal Bleeker-Rovers Geert Wanten |
author_facet |
Michelle Gompelman Renée Tuinte Erik Aarntzen Ilse Kouijzer Eline van Leerdam Marvin Berrevoets Jaap Ten Oever Chantal Bleeker-Rovers Geert Wanten |
author_sort |
Michelle Gompelman |
title |
The diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia |
title_short |
The diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia |
title_full |
The diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia |
title_fullStr |
The diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia |
title_full_unstemmed |
The diagnostic value of [18F]FDG-PET/CT in detecting septic thrombosis in patients with central venous catheter-related Staphylococcus aureus bacteremia |
title_sort |
diagnostic value of [18f]fdg-pet/ct in detecting septic thrombosis in patients with central venous catheter-related staphylococcus aureus bacteremia |
publisher |
Elsevier |
publishDate |
2021 |
url |
https://doaj.org/article/58e3b6e5e5284d1d9cf1313bd4d44b47 |
work_keys_str_mv |
AT michellegompelman thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT reneetuinte thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT erikaarntzen thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT ilsekouijzer thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT elinevanleerdam thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT marvinberrevoets thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT jaaptenoever thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT chantalbleekerrovers thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT geertwanten thediagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT michellegompelman diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT reneetuinte diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT erikaarntzen diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT ilsekouijzer diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT elinevanleerdam diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT marvinberrevoets diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT jaaptenoever diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT chantalbleekerrovers diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia AT geertwanten diagnosticvalueof18ffdgpetctindetectingsepticthrombosisinpatientswithcentralvenouscatheterrelatedstaphylococcusaureusbacteremia |
_version_ |
1718430013850648576 |