Histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage

Abstract We aimed to determine the proper modified thresholds for detecting and weighting CAC scores at 100 kV through histogram matching in comparison with 120 kV as a standard reference. From the training set (680 participants), modified thresholds at 100 kV were obtained through histogram matchin...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sungwon Kim, Chan Joo Lee, Kyunghwa Han, Kye Ho Lee, Hye-Jeong Lee, Sungha Park
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/5b92067d9ea24fef9899975b4164cb01
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:5b92067d9ea24fef9899975b4164cb01
record_format dspace
spelling oai:doaj.org-article:5b92067d9ea24fef9899975b4164cb012021-12-02T16:38:49ZHistogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage10.1038/s41598-021-96695-92045-2322https://doaj.org/article/5b92067d9ea24fef9899975b4164cb012021-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-96695-9https://doaj.org/toc/2045-2322Abstract We aimed to determine the proper modified thresholds for detecting and weighting CAC scores at 100 kV through histogram matching in comparison with 120 kV as a standard reference. From the training set (680 participants), modified thresholds at 100 kV were obtained through histogram matching of calcium pixels to 120 kV. From the validation set (213 participants), a standard CAC score at 120 kV, and modified CAC score at 100 kV using modified thresholds were compare through the paired t test and the Bland–Altman plot. Agreement for risk categories (no, minimal, mild, moderate, and severe) was evaluated using kappa statistics. Radiation doses were also compared. For the validation set, there was no significant difference between standard (median, 18.7; IQR, 0.0–207.0) and modified (median, 17.3; IQR, 0.0–220.9) CAC scores (P = 0.689). A small bias was achieved (0.74) with 95% limits of agreement from − 52.35 to 53.83. Agreements for risk categories were excellent (κ = 0.994). The mean dose-length-product of 100-kV scanning (30.1 ± 0.8 mGy * cm) was significantly decreased compared to 120-kV scanning (42.9 ± 0.6 mGy * cm) (P < 0.001). Histogram-derived modified thresholds at 100 kV can enable accurate CAC scoring while reducing radiation exposure.Sungwon KimChan Joo LeeKyunghwa HanKye Ho LeeHye-Jeong LeeSungha ParkNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-9 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Sungwon Kim
Chan Joo Lee
Kyunghwa Han
Kye Ho Lee
Hye-Jeong Lee
Sungha Park
Histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage
description Abstract We aimed to determine the proper modified thresholds for detecting and weighting CAC scores at 100 kV through histogram matching in comparison with 120 kV as a standard reference. From the training set (680 participants), modified thresholds at 100 kV were obtained through histogram matching of calcium pixels to 120 kV. From the validation set (213 participants), a standard CAC score at 120 kV, and modified CAC score at 100 kV using modified thresholds were compare through the paired t test and the Bland–Altman plot. Agreement for risk categories (no, minimal, mild, moderate, and severe) was evaluated using kappa statistics. Radiation doses were also compared. For the validation set, there was no significant difference between standard (median, 18.7; IQR, 0.0–207.0) and modified (median, 17.3; IQR, 0.0–220.9) CAC scores (P = 0.689). A small bias was achieved (0.74) with 95% limits of agreement from − 52.35 to 53.83. Agreements for risk categories were excellent (κ = 0.994). The mean dose-length-product of 100-kV scanning (30.1 ± 0.8 mGy * cm) was significantly decreased compared to 120-kV scanning (42.9 ± 0.6 mGy * cm) (P < 0.001). Histogram-derived modified thresholds at 100 kV can enable accurate CAC scoring while reducing radiation exposure.
format article
author Sungwon Kim
Chan Joo Lee
Kyunghwa Han
Kye Ho Lee
Hye-Jeong Lee
Sungha Park
author_facet Sungwon Kim
Chan Joo Lee
Kyunghwa Han
Kye Ho Lee
Hye-Jeong Lee
Sungha Park
author_sort Sungwon Kim
title Histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage
title_short Histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage
title_full Histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage
title_fullStr Histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage
title_full_unstemmed Histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage
title_sort histogram-derived modified thresholds for coronary artery calcium scoring with lower tube voltage
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/5b92067d9ea24fef9899975b4164cb01
work_keys_str_mv AT sungwonkim histogramderivedmodifiedthresholdsforcoronaryarterycalciumscoringwithlowertubevoltage
AT chanjoolee histogramderivedmodifiedthresholdsforcoronaryarterycalciumscoringwithlowertubevoltage
AT kyunghwahan histogramderivedmodifiedthresholdsforcoronaryarterycalciumscoringwithlowertubevoltage
AT kyeholee histogramderivedmodifiedthresholdsforcoronaryarterycalciumscoringwithlowertubevoltage
AT hyejeonglee histogramderivedmodifiedthresholdsforcoronaryarterycalciumscoringwithlowertubevoltage
AT sunghapark histogramderivedmodifiedthresholdsforcoronaryarterycalciumscoringwithlowertubevoltage
_version_ 1718383574599598080