A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT

The purpose of this study was to analyze the effectiveness of newly developed dental dual-energy (DE) cone-beam computed tomography (CBCT) to compare both the voxel values in hard bone tissue of DE-CBCT and multidetector computed tomography (MDCT) images, collected in a clinical trial conducted at S...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Sungho Chang, Sang Chul Lee
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Acceso en línea:https://doaj.org/article/5bf7d842c908469ab5d39a6948060e4a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:5bf7d842c908469ab5d39a6948060e4a
record_format dspace
spelling oai:doaj.org-article:5bf7d842c908469ab5d39a6948060e4a2021-11-25T18:57:24ZA Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT10.3390/s212275521424-8220https://doaj.org/article/5bf7d842c908469ab5d39a6948060e4a2021-11-01T00:00:00Zhttps://www.mdpi.com/1424-8220/21/22/7552https://doaj.org/toc/1424-8220The purpose of this study was to analyze the effectiveness of newly developed dental dual-energy (DE) cone-beam computed tomography (CBCT) to compare both the voxel values in hard bone tissue of DE-CBCT and multidetector computed tomography (MDCT) images, collected in a clinical trial conducted at Seoul National University Dental Hospital. A software implemented as a scripted module of a three-dimensional (3D) slicer was developed to register the volume data from the MDCT space to DE-CBCT, locate the same 3D regions of interest (ROIs) in each image space, and extract the statistics of the ROIs. The mean values were paired and used as representative values of the ROIs. A scatter plot with the line of equality and Bland–Altman (BA) plot of difference for a pair of measured means were used for statistical analysis. Of the ROI pairs, 96% were within ±15% from the identity line, and more than 95% of the measured ROI pairs were within the limits of agreement of the 95% confidence intervals (CIs), with the CI of the limits in BA plots. The newly developed dental DE-CBCT showed a level of voxel value accuracy similar to that of MDCT.Sungho ChangSang Chul LeeMDPI AGarticledual-energycone beamcomputed tomographybone densityChemical technologyTP1-1185ENSensors, Vol 21, Iss 7552, p 7552 (2021)
institution DOAJ
collection DOAJ
language EN
topic dual-energy
cone beam
computed tomography
bone density
Chemical technology
TP1-1185
spellingShingle dual-energy
cone beam
computed tomography
bone density
Chemical technology
TP1-1185
Sungho Chang
Sang Chul Lee
A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
description The purpose of this study was to analyze the effectiveness of newly developed dental dual-energy (DE) cone-beam computed tomography (CBCT) to compare both the voxel values in hard bone tissue of DE-CBCT and multidetector computed tomography (MDCT) images, collected in a clinical trial conducted at Seoul National University Dental Hospital. A software implemented as a scripted module of a three-dimensional (3D) slicer was developed to register the volume data from the MDCT space to DE-CBCT, locate the same 3D regions of interest (ROIs) in each image space, and extract the statistics of the ROIs. The mean values were paired and used as representative values of the ROIs. A scatter plot with the line of equality and Bland–Altman (BA) plot of difference for a pair of measured means were used for statistical analysis. Of the ROI pairs, 96% were within ±15% from the identity line, and more than 95% of the measured ROI pairs were within the limits of agreement of the 95% confidence intervals (CIs), with the CI of the limits in BA plots. The newly developed dental DE-CBCT showed a level of voxel value accuracy similar to that of MDCT.
format article
author Sungho Chang
Sang Chul Lee
author_facet Sungho Chang
Sang Chul Lee
author_sort Sungho Chang
title A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_short A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_full A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_fullStr A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_full_unstemmed A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_sort comparative study on the voxel values in alveolar bones acquired by mdct and newly developed dental dual-energy cbct
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/5bf7d842c908469ab5d39a6948060e4a
work_keys_str_mv AT sunghochang acomparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct
AT sangchullee acomparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct
AT sunghochang comparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct
AT sangchullee comparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct
_version_ 1718410464375865344