Using of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires
In the present research the flame retardancy to buildings and industrial foundations which are manufacturing from advanced polymeric composite material was increased by coating it with surface layer included flame retardant material. A(3mm) thick antimony tetroxide was used as a coated layer...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Al-Khwarizmi College of Engineering – University of Baghdad
2011
|
Materias: | |
Acceso en línea: | https://doaj.org/article/5d081e48218b4a169f81492d9dc949ed |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:5d081e48218b4a169f81492d9dc949ed |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:5d081e48218b4a169f81492d9dc949ed2021-12-02T05:27:12ZUsing of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires1818-11712312-0789https://doaj.org/article/5d081e48218b4a169f81492d9dc949ed2011-12-01T00:00:00Zhttp://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/83https://doaj.org/toc/1818-1171https://doaj.org/toc/2312-0789 In the present research the flame retardancy to buildings and industrial foundations which are manufacturing from advanced polymeric composite material was increased by coating it with surface layer included flame retardant material. A(3mm) thick antimony tetroxide was used as a coated layer to retard and prevent the flame spread to the coating surface of polyester resin (SIROPOL 8340-PI) reinforced with hybrid fibers as a woven roving (°45-°0) consist of carbon and kevlar (49) fibers, and exposed it to direct flame generated from gas torch at temperature of (2000ºC), at different exposed distance (10,15,20mm)and study the rang of resistance for this layer and its ability to protect the under composite material . The result obtained from erosion test show an improvement to the resistance of the composite material to high temperature after addition of antimony tetroxide layer and this resistance increased with increasing the exposed distance of flame . Ali I. Al-MosawiAbbas A. MahmoodAli J. SalamanNaser A. AlwashAl-Khwarizmi College of Engineering – University of Baghdadarticleالكلمات المفتاحية: إعاقة اللّهَب ، مادة متراكبة ، ألياف هجينةChemical engineeringTP155-156Engineering (General). Civil engineering (General)TA1-2040ENAl-Khawarizmi Engineering Journal, Vol 7, Iss 4 (2011) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
الكلمات المفتاحية: إعاقة اللّهَب ، مادة متراكبة ، ألياف هجينة Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 |
spellingShingle |
الكلمات المفتاحية: إعاقة اللّهَب ، مادة متراكبة ، ألياف هجينة Chemical engineering TP155-156 Engineering (General). Civil engineering (General) TA1-2040 Ali I. Al-Mosawi Abbas A. Mahmood Ali J. Salaman Naser A. Alwash Using of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires |
description |
In the present research the flame retardancy to buildings and industrial foundations which are manufacturing from advanced polymeric composite material was increased by coating it with surface layer included flame retardant material. A(3mm) thick antimony tetroxide was used as a coated layer to retard and prevent the flame spread to the coating surface of polyester resin (SIROPOL 8340-PI) reinforced with hybrid fibers as a woven roving (°45-°0) consist of carbon and kevlar (49) fibers, and exposed it to direct flame generated from gas torch at temperature of (2000ºC), at different exposed distance (10,15,20mm)and study the rang of resistance for this layer and its ability to protect the under composite material . The result obtained from erosion test show an improvement to the resistance of the composite material to high temperature after addition of antimony tetroxide layer and this resistance increased with increasing the exposed distance of flame .
|
format |
article |
author |
Ali I. Al-Mosawi Abbas A. Mahmood Ali J. Salaman Naser A. Alwash |
author_facet |
Ali I. Al-Mosawi Abbas A. Mahmood Ali J. Salaman Naser A. Alwash |
author_sort |
Ali I. Al-Mosawi |
title |
Using of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires |
title_short |
Using of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires |
title_full |
Using of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires |
title_fullStr |
Using of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires |
title_full_unstemmed |
Using of Coating Technique by Inorganic Flame Retardants to Protect Civil and Industrial Foundations from Fires |
title_sort |
using of coating technique by inorganic flame retardants to protect civil and industrial foundations from fires |
publisher |
Al-Khwarizmi College of Engineering – University of Baghdad |
publishDate |
2011 |
url |
https://doaj.org/article/5d081e48218b4a169f81492d9dc949ed |
work_keys_str_mv |
AT aliialmosawi usingofcoatingtechniquebyinorganicflameretardantstoprotectcivilandindustrialfoundationsfromfires AT abbasamahmood usingofcoatingtechniquebyinorganicflameretardantstoprotectcivilandindustrialfoundationsfromfires AT alijsalaman usingofcoatingtechniquebyinorganicflameretardantstoprotectcivilandindustrialfoundationsfromfires AT naseraalwash usingofcoatingtechniquebyinorganicflameretardantstoprotectcivilandindustrialfoundationsfromfires |
_version_ |
1718400412316336128 |