Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy

Abstract A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol conc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Bei Zheng, Wentao Li, Lin Liu, Xin Wang, Chen Chen, Zhiyong Yu, Hongyan Li
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/5d6e484bf52c4f3fbdbd21aef50d023f
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:5d6e484bf52c4f3fbdbd21aef50d023f
record_format dspace
spelling oai:doaj.org-article:5d6e484bf52c4f3fbdbd21aef50d023f2021-12-02T16:06:23ZDetermination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy10.1038/s41598-017-09050-22045-2322https://doaj.org/article/5d6e484bf52c4f3fbdbd21aef50d023f2017-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-09050-2https://doaj.org/toc/2045-2322Abstract A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration. The SiO2/PDMS coating was prepared by sol-gel method and characterized with respect to morphology and specific surface area. The results of field-emission scanning electron microscope (FE-SEM) and N2 adsorption-desorption as well as phenol adsorption experiments denoted that SiO2/PDMS has larger surface area and better adsorption capacity than commercial PDMS. The extraction efficiency of phenol with SiO2/PDMS coated stirring bar was optimized in terms of ion strength, flow rate of phenol-involved influent, type of desorption solvent and desorption time. More than 75% of phenol desorption efficiency could be kept even after 50 cycles of extraction, indicating the high stability of the SiO2/PDMS coated stirring bar. Approximately 0.16 mg/L 2, 5-dimethylphenol (2, 5-DMP), which was 34-fold more toxic than phenol, was detected in water through HPLC-FTIR. However, 2, 5-DMP could be oxidized to 5-methy-2-hydroxy benzaldehyde after disinfection in drinking water treatment process. Therefore, the proposed method of SiO2/PDMS-SBSE-HPLC-FTIR is successfully applied in the analysis of phenols isomers in aqueous environment.Bei ZhengWentao LiLin LiuXin WangChen ChenZhiyong YuHongyan LiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-10 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Bei Zheng
Wentao Li
Lin Liu
Xin Wang
Chen Chen
Zhiyong Yu
Hongyan Li
Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy
description Abstract A novel nanosilica/polydimethylsiloxane (SiO2/PDMS) coated stirring bar was adopted in the sorption extraction (SBSE) of phenols in water, and the high performance liquid chromatography-fourier transform infrared spectroscopy (HPLC-FTIR) was subsequently used to determination of phenol concentration. The SiO2/PDMS coating was prepared by sol-gel method and characterized with respect to morphology and specific surface area. The results of field-emission scanning electron microscope (FE-SEM) and N2 adsorption-desorption as well as phenol adsorption experiments denoted that SiO2/PDMS has larger surface area and better adsorption capacity than commercial PDMS. The extraction efficiency of phenol with SiO2/PDMS coated stirring bar was optimized in terms of ion strength, flow rate of phenol-involved influent, type of desorption solvent and desorption time. More than 75% of phenol desorption efficiency could be kept even after 50 cycles of extraction, indicating the high stability of the SiO2/PDMS coated stirring bar. Approximately 0.16 mg/L 2, 5-dimethylphenol (2, 5-DMP), which was 34-fold more toxic than phenol, was detected in water through HPLC-FTIR. However, 2, 5-DMP could be oxidized to 5-methy-2-hydroxy benzaldehyde after disinfection in drinking water treatment process. Therefore, the proposed method of SiO2/PDMS-SBSE-HPLC-FTIR is successfully applied in the analysis of phenols isomers in aqueous environment.
format article
author Bei Zheng
Wentao Li
Lin Liu
Xin Wang
Chen Chen
Zhiyong Yu
Hongyan Li
author_facet Bei Zheng
Wentao Li
Lin Liu
Xin Wang
Chen Chen
Zhiyong Yu
Hongyan Li
author_sort Bei Zheng
title Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy
title_short Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy
title_full Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy
title_fullStr Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy
title_full_unstemmed Determination of Phenols Isomers in Water by Novel Nanosilica/Polydimethylsiloxane-Coated Stirring Bar Combined with High Performance Liquid Chromatography-Fourier Transform Infrared Spectroscopy
title_sort determination of phenols isomers in water by novel nanosilica/polydimethylsiloxane-coated stirring bar combined with high performance liquid chromatography-fourier transform infrared spectroscopy
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/5d6e484bf52c4f3fbdbd21aef50d023f
work_keys_str_mv AT beizheng determinationofphenolsisomersinwaterbynovelnanosilicapolydimethylsiloxanecoatedstirringbarcombinedwithhighperformanceliquidchromatographyfouriertransforminfraredspectroscopy
AT wentaoli determinationofphenolsisomersinwaterbynovelnanosilicapolydimethylsiloxanecoatedstirringbarcombinedwithhighperformanceliquidchromatographyfouriertransforminfraredspectroscopy
AT linliu determinationofphenolsisomersinwaterbynovelnanosilicapolydimethylsiloxanecoatedstirringbarcombinedwithhighperformanceliquidchromatographyfouriertransforminfraredspectroscopy
AT xinwang determinationofphenolsisomersinwaterbynovelnanosilicapolydimethylsiloxanecoatedstirringbarcombinedwithhighperformanceliquidchromatographyfouriertransforminfraredspectroscopy
AT chenchen determinationofphenolsisomersinwaterbynovelnanosilicapolydimethylsiloxanecoatedstirringbarcombinedwithhighperformanceliquidchromatographyfouriertransforminfraredspectroscopy
AT zhiyongyu determinationofphenolsisomersinwaterbynovelnanosilicapolydimethylsiloxanecoatedstirringbarcombinedwithhighperformanceliquidchromatographyfouriertransforminfraredspectroscopy
AT hongyanli determinationofphenolsisomersinwaterbynovelnanosilicapolydimethylsiloxanecoatedstirringbarcombinedwithhighperformanceliquidchromatographyfouriertransforminfraredspectroscopy
_version_ 1718385025181810688