EVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD

Objective: To develop and evaluate a new high-performance liquid chromatography (HPLC) based method for Voriconazole (VRC) analysis in blood. Study Design: Cross sectional study. Place and Duration of Study: Department of Chemical Pathology and Endocrinology Armed Forces Institute of Pathology...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ambreen Rehman, Naveed Asif, Ayesha Hafeez, Aamir Ijaz, Muhammad Waseem, Qurat Ul Ain
Formato: article
Lenguaje:EN
Publicado: Army Medical College Rawalpindi 2019
Materias:
R
Acceso en línea:https://doaj.org/article/5f26cfa7924e47cd92293b3c22ba5cd4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:5f26cfa7924e47cd92293b3c22ba5cd4
record_format dspace
spelling oai:doaj.org-article:5f26cfa7924e47cd92293b3c22ba5cd42021-11-12T02:51:36ZEVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD0030-96482411-8842https://doaj.org/article/5f26cfa7924e47cd92293b3c22ba5cd42019-06-01T00:00:00Zhttps://www.pafmj.org/index.php/PAFMJ/article/view/3019/2257https://doaj.org/toc/0030-9648https://doaj.org/toc/2411-8842Objective: To develop and evaluate a new high-performance liquid chromatography (HPLC) based method for Voriconazole (VRC) analysis in blood. Study Design: Cross sectional study. Place and Duration of Study: Department of Chemical Pathology and Endocrinology Armed Forces Institute of Pathology (AFIP), Rawalpindi, from May 2017 to Oct 2017. Material and Methods: Trough venous blood samples of twenty-five patients on VRC therapy were collected, after five days of starting VRC. Samples were centrifuged. About 100 μl of Lorazepam as internal standard (5.0 μg/ml), was added to 0.5ml of each sample. Then extraction was done with 4.0 ml of mixture of hexane and ethyl acetate. Centrifugation was again done and supernatant layer was collected and dried under nitrogen. It was reconstituted with 200μl of deionized water and acetonitrile. Samples were analyzed on HPLC. Results: Method was validated in terms of linearity, limit of detection, limit of quantification, precision, accuracy, recovery, analytical specificity and stability. Linearity calibration curve plot for assay obtained was linear over analytical measurement range of 1.0 to 8.0μg/ml and correlation coefficient was 0.99. Mean intra-assay accuracy for 1.0, 5.0 and 8.0 μg/ml was 96%, 98.6%, 99.5% respectively, and percentage Relative Standard Deviation (RSD) was 5.9%, 1.15%, 1.44% respectively. Mean inter-assay accuracy for 1.0, 5.0 and 8.0 μg/ml was 95%, 98.6%, 99.5% respectively, and % RSD was 5.68%, 1.03% and 1.01% respectively. Limit of Detection (LOD) was 0.25 μg/mL and Limit of Quantitation (LOQ) was 1.0 μg/ml. Conclusion: HPLC based method for VRC determination is accurate and specific with good clinical correlation. This method may be used in routine for Therapeutic Drug Monitoring (TDM) of VRC.Ambreen RehmanNaveed AsifAyesha HafeezAamir IjazMuhammad WaseemQurat Ul AinArmy Medical College Rawalpindiarticlehigh performance liquid chromatographytherapeutic drug monitoringMedicineRMedicine (General)R5-920ENPakistan Armed Forces Medical Journal, Vol 69, Iss 3, Pp 516-521 (2019)
institution DOAJ
collection DOAJ
language EN
topic high performance liquid chromatography
therapeutic drug monitoring
Medicine
R
Medicine (General)
R5-920
spellingShingle high performance liquid chromatography
therapeutic drug monitoring
Medicine
R
Medicine (General)
R5-920
Ambreen Rehman
Naveed Asif
Ayesha Hafeez
Aamir Ijaz
Muhammad Waseem
Qurat Ul Ain
EVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD
description Objective: To develop and evaluate a new high-performance liquid chromatography (HPLC) based method for Voriconazole (VRC) analysis in blood. Study Design: Cross sectional study. Place and Duration of Study: Department of Chemical Pathology and Endocrinology Armed Forces Institute of Pathology (AFIP), Rawalpindi, from May 2017 to Oct 2017. Material and Methods: Trough venous blood samples of twenty-five patients on VRC therapy were collected, after five days of starting VRC. Samples were centrifuged. About 100 μl of Lorazepam as internal standard (5.0 μg/ml), was added to 0.5ml of each sample. Then extraction was done with 4.0 ml of mixture of hexane and ethyl acetate. Centrifugation was again done and supernatant layer was collected and dried under nitrogen. It was reconstituted with 200μl of deionized water and acetonitrile. Samples were analyzed on HPLC. Results: Method was validated in terms of linearity, limit of detection, limit of quantification, precision, accuracy, recovery, analytical specificity and stability. Linearity calibration curve plot for assay obtained was linear over analytical measurement range of 1.0 to 8.0μg/ml and correlation coefficient was 0.99. Mean intra-assay accuracy for 1.0, 5.0 and 8.0 μg/ml was 96%, 98.6%, 99.5% respectively, and percentage Relative Standard Deviation (RSD) was 5.9%, 1.15%, 1.44% respectively. Mean inter-assay accuracy for 1.0, 5.0 and 8.0 μg/ml was 95%, 98.6%, 99.5% respectively, and % RSD was 5.68%, 1.03% and 1.01% respectively. Limit of Detection (LOD) was 0.25 μg/mL and Limit of Quantitation (LOQ) was 1.0 μg/ml. Conclusion: HPLC based method for VRC determination is accurate and specific with good clinical correlation. This method may be used in routine for Therapeutic Drug Monitoring (TDM) of VRC.
format article
author Ambreen Rehman
Naveed Asif
Ayesha Hafeez
Aamir Ijaz
Muhammad Waseem
Qurat Ul Ain
author_facet Ambreen Rehman
Naveed Asif
Ayesha Hafeez
Aamir Ijaz
Muhammad Waseem
Qurat Ul Ain
author_sort Ambreen Rehman
title EVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD
title_short EVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD
title_full EVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD
title_fullStr EVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD
title_full_unstemmed EVALUATION OF A NEW HIGH PERFORMANCE LIQUID CHROMATOGRAPHY BASED METHOD FOR VORICONAZOLE ANALYSIS IN BLOOD
title_sort evaluation of a new high performance liquid chromatography based method for voriconazole analysis in blood
publisher Army Medical College Rawalpindi
publishDate 2019
url https://doaj.org/article/5f26cfa7924e47cd92293b3c22ba5cd4
work_keys_str_mv AT ambreenrehman evaluationofanewhighperformanceliquidchromatographybasedmethodforvoriconazoleanalysisinblood
AT naveedasif evaluationofanewhighperformanceliquidchromatographybasedmethodforvoriconazoleanalysisinblood
AT ayeshahafeez evaluationofanewhighperformanceliquidchromatographybasedmethodforvoriconazoleanalysisinblood
AT aamirijaz evaluationofanewhighperformanceliquidchromatographybasedmethodforvoriconazoleanalysisinblood
AT muhammadwaseem evaluationofanewhighperformanceliquidchromatographybasedmethodforvoriconazoleanalysisinblood
AT quratulain evaluationofanewhighperformanceliquidchromatographybasedmethodforvoriconazoleanalysisinblood
_version_ 1718431292792504320