Feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.

Stereotactic ablative radiotherapy is being increasingly adopted in the treatment of lung tumors. The use of proton beam therapy can further reduce dose to normal structures. However, uncertainty exists in proton-based treatment plans, including range uncertainties, large sensitivity to position unc...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Benjamin Mou, Chris J Beltran, Sean S Park, Kenneth R Olivier, Keith M Furutani
Formato: article
Lenguaje:EN
Publicado: Public Library of Science (PLoS) 2014
Materias:
R
Q
Acceso en línea:https://doaj.org/article/60acd1a3f1734f14b8b1a024b939f1f2
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:60acd1a3f1734f14b8b1a024b939f1f2
record_format dspace
spelling oai:doaj.org-article:60acd1a3f1734f14b8b1a024b939f1f22021-11-18T08:17:39ZFeasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.1932-620310.1371/journal.pone.0098621https://doaj.org/article/60acd1a3f1734f14b8b1a024b939f1f22014-01-01T00:00:00Zhttps://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24887068/pdf/?tool=EBIhttps://doaj.org/toc/1932-6203Stereotactic ablative radiotherapy is being increasingly adopted in the treatment of lung tumors. The use of proton beam therapy can further reduce dose to normal structures. However, uncertainty exists in proton-based treatment plans, including range uncertainties, large sensitivity to position uncertainty, and calculation of dose deposition in heterogeneous areas. This study investigated the feasibility of proton transmission beams, i.e. without the Bragg peak, to treat lung tumors with stereotactic ablative radiotherapy. We compared three representative treatment plans using proton transmission beams versus conformal static-gantry photon beams. It was found that proton treatment plans using transmission beams passing through the patient were feasible and demonstrated lower dose to normal structures and markedly reduced treatment times than photon plans. This is the first study to demonstrate the feasibility of proton-based stereotactic ablative radiotherapy planning for lung tumors using proton transmission beams alone. Further research using this novel approach for proton-based planning is warranted.Benjamin MouChris J BeltranSean S ParkKenneth R OlivierKeith M FurutaniPublic Library of Science (PLoS)articleMedicineRScienceQENPLoS ONE, Vol 9, Iss 6, p e98621 (2014)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Benjamin Mou
Chris J Beltran
Sean S Park
Kenneth R Olivier
Keith M Furutani
Feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.
description Stereotactic ablative radiotherapy is being increasingly adopted in the treatment of lung tumors. The use of proton beam therapy can further reduce dose to normal structures. However, uncertainty exists in proton-based treatment plans, including range uncertainties, large sensitivity to position uncertainty, and calculation of dose deposition in heterogeneous areas. This study investigated the feasibility of proton transmission beams, i.e. without the Bragg peak, to treat lung tumors with stereotactic ablative radiotherapy. We compared three representative treatment plans using proton transmission beams versus conformal static-gantry photon beams. It was found that proton treatment plans using transmission beams passing through the patient were feasible and demonstrated lower dose to normal structures and markedly reduced treatment times than photon plans. This is the first study to demonstrate the feasibility of proton-based stereotactic ablative radiotherapy planning for lung tumors using proton transmission beams alone. Further research using this novel approach for proton-based planning is warranted.
format article
author Benjamin Mou
Chris J Beltran
Sean S Park
Kenneth R Olivier
Keith M Furutani
author_facet Benjamin Mou
Chris J Beltran
Sean S Park
Kenneth R Olivier
Keith M Furutani
author_sort Benjamin Mou
title Feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.
title_short Feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.
title_full Feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.
title_fullStr Feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.
title_full_unstemmed Feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.
title_sort feasibility of proton transmission-beam stereotactic ablative radiotherapy versus photon stereotactic ablative radiotherapy for lung tumors: a dosimetric and feasibility study.
publisher Public Library of Science (PLoS)
publishDate 2014
url https://doaj.org/article/60acd1a3f1734f14b8b1a024b939f1f2
work_keys_str_mv AT benjaminmou feasibilityofprotontransmissionbeamstereotacticablativeradiotherapyversusphotonstereotacticablativeradiotherapyforlungtumorsadosimetricandfeasibilitystudy
AT chrisjbeltran feasibilityofprotontransmissionbeamstereotacticablativeradiotherapyversusphotonstereotacticablativeradiotherapyforlungtumorsadosimetricandfeasibilitystudy
AT seanspark feasibilityofprotontransmissionbeamstereotacticablativeradiotherapyversusphotonstereotacticablativeradiotherapyforlungtumorsadosimetricandfeasibilitystudy
AT kennethrolivier feasibilityofprotontransmissionbeamstereotacticablativeradiotherapyversusphotonstereotacticablativeradiotherapyforlungtumorsadosimetricandfeasibilitystudy
AT keithmfurutani feasibilityofprotontransmissionbeamstereotacticablativeradiotherapyversusphotonstereotacticablativeradiotherapyforlungtumorsadosimetricandfeasibilitystudy
_version_ 1718421924484218880