Accuracy and precision of cap thickness in small incision lenticule extraction

Engin Bilge Ozgurhan,1 Alper Agca,1 Ercument Bozkurt,1 Baran Gencer,2 Ugur Celik,1 Kadir İlker Cankaya,1 Ahmet Demirok,1,3 Omer Faruk Yilmaz41Beyoglu Eye Training and Research Hospital, Istanbul, Turkey; 2Ophthalmology Department, Faculty of Medicine, Çanakkale Onsekiz Mart University, &a...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Ozgurhan EB, Agca A, Bozkurt E, Gencer B, Celik U, Cankaya KI, Demirok A, Yilmaz OF
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2013
Materias:
Acceso en línea:https://doaj.org/article/60c2e40dbf974b0889336541821ecdf0
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:60c2e40dbf974b0889336541821ecdf0
record_format dspace
spelling oai:doaj.org-article:60c2e40dbf974b0889336541821ecdf02021-12-02T00:36:56ZAccuracy and precision of cap thickness in small incision lenticule extraction1177-54671177-5483https://doaj.org/article/60c2e40dbf974b0889336541821ecdf02013-05-01T00:00:00Zhttp://www.dovepress.com/accuracy-and-precision-of-cap-thickness-in-small-incision-lenticule-ex-a13104https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Engin Bilge Ozgurhan,1 Alper Agca,1 Ercument Bozkurt,1 Baran Gencer,2 Ugur Celik,1 Kadir İlker Cankaya,1 Ahmet Demirok,1,3 Omer Faruk Yilmaz41Beyoglu Eye Training and Research Hospital, Istanbul, Turkey; 2Ophthalmology Department, Faculty of Medicine, Çanakkale Onsekiz Mart University, Çanakkale, Turkey; 3Department of Ophthalmology, Medeniyet University, Istanbul, Turkey; 4Private practice, Istanbul, TurkeyAims: To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK).Settings and design: Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study.Materials and methods: Medical records of patients who had SMILE in one eye and femto-LASIK in the other eye were reviewed. Visante corneal Optical Coherence Tomography (OCT) images at 1 week and 1 month post-surgery were analyzed. Both cap and flap thickness at the temporal edge and the nasal edge were measured and compared to each other.Statistical analyses used: PAWS Statistics 18 and unpaired student t-test were used to compare the groups.Results: The study included 66 eyes of 33 patients (24.7 ± 3.8 years, 20 females and 13 males). Mean flap thickness was 114.88 µm ± 4.96 µm, and mean cap thickness was 114.63 µm ± 5.18 µm. In group 1 (SMILE), cap thickness values were 115.84 µm ± 6.84 µm, 114.75 µm ± 7.36 µm, 113.66 µm ± 6.88 µm, and 114.27 µm ± 6.90 µm in measurement zones 1, 2, 3, and 4, respectively. In group 2 (FemtoLASIK), flap corneal thickness values were 115.96 mmHg ± 7.01 mmHg, 114.72 mmHg ± 7.17 mmHg, 113.54 mmHg ± 6.45 mmHg, and 115.30 mmHg ± 6.64 mmHg in measurement zones 1, 2, 3, and 4, respectively. In both groups, no statistically significant change within the measurement zones was observed.Conclusion: The predictability of cap thickness in SMILE surgery does not differ from the femto-LASIK flaps created using the same femtosecond laser platform.Keywords: SMILE, small incision lenticule extractionOzgurhan EBAgca ABozkurt EGencer BCelik UCankaya KIDemirok AYilmaz OFDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2013, Iss default, Pp 923-926 (2013)
institution DOAJ
collection DOAJ
language EN
topic Ophthalmology
RE1-994
spellingShingle Ophthalmology
RE1-994
Ozgurhan EB
Agca A
Bozkurt E
Gencer B
Celik U
Cankaya KI
Demirok A
Yilmaz OF
Accuracy and precision of cap thickness in small incision lenticule extraction
description Engin Bilge Ozgurhan,1 Alper Agca,1 Ercument Bozkurt,1 Baran Gencer,2 Ugur Celik,1 Kadir İlker Cankaya,1 Ahmet Demirok,1,3 Omer Faruk Yilmaz41Beyoglu Eye Training and Research Hospital, Istanbul, Turkey; 2Ophthalmology Department, Faculty of Medicine, Çanakkale Onsekiz Mart University, Çanakkale, Turkey; 3Department of Ophthalmology, Medeniyet University, Istanbul, Turkey; 4Private practice, Istanbul, TurkeyAims: To report and compare the cap thickness predictability of small incision lenticule extraction (SMILE) and flap thickness of femtosecond laser-assisted in situ keratomileusis (femto-LASIK).Settings and design: Beyoglu Eye Training and Research Hospital, Refractive Surgery Department, Istanbul, Turkey. Retrospective pilot study.Materials and methods: Medical records of patients who had SMILE in one eye and femto-LASIK in the other eye were reviewed. Visante corneal Optical Coherence Tomography (OCT) images at 1 week and 1 month post-surgery were analyzed. Both cap and flap thickness at the temporal edge and the nasal edge were measured and compared to each other.Statistical analyses used: PAWS Statistics 18 and unpaired student t-test were used to compare the groups.Results: The study included 66 eyes of 33 patients (24.7 ± 3.8 years, 20 females and 13 males). Mean flap thickness was 114.88 µm ± 4.96 µm, and mean cap thickness was 114.63 µm ± 5.18 µm. In group 1 (SMILE), cap thickness values were 115.84 µm ± 6.84 µm, 114.75 µm ± 7.36 µm, 113.66 µm ± 6.88 µm, and 114.27 µm ± 6.90 µm in measurement zones 1, 2, 3, and 4, respectively. In group 2 (FemtoLASIK), flap corneal thickness values were 115.96 mmHg ± 7.01 mmHg, 114.72 mmHg ± 7.17 mmHg, 113.54 mmHg ± 6.45 mmHg, and 115.30 mmHg ± 6.64 mmHg in measurement zones 1, 2, 3, and 4, respectively. In both groups, no statistically significant change within the measurement zones was observed.Conclusion: The predictability of cap thickness in SMILE surgery does not differ from the femto-LASIK flaps created using the same femtosecond laser platform.Keywords: SMILE, small incision lenticule extraction
format article
author Ozgurhan EB
Agca A
Bozkurt E
Gencer B
Celik U
Cankaya KI
Demirok A
Yilmaz OF
author_facet Ozgurhan EB
Agca A
Bozkurt E
Gencer B
Celik U
Cankaya KI
Demirok A
Yilmaz OF
author_sort Ozgurhan EB
title Accuracy and precision of cap thickness in small incision lenticule extraction
title_short Accuracy and precision of cap thickness in small incision lenticule extraction
title_full Accuracy and precision of cap thickness in small incision lenticule extraction
title_fullStr Accuracy and precision of cap thickness in small incision lenticule extraction
title_full_unstemmed Accuracy and precision of cap thickness in small incision lenticule extraction
title_sort accuracy and precision of cap thickness in small incision lenticule extraction
publisher Dove Medical Press
publishDate 2013
url https://doaj.org/article/60c2e40dbf974b0889336541821ecdf0
work_keys_str_mv AT ozgurhaneb accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
AT agcaa accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
AT bozkurte accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
AT gencerb accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
AT celiku accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
AT cankayaki accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
AT demiroka accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
AT yilmazof accuracyandprecisionofcapthicknessinsmallincisionlenticuleextraction
_version_ 1718403622704775168