Effect of gender, muscle type and skinfold thickness on myometric parameters in young people

Background The aim of the study was to compare the mechanical properties of three human skeletal muscles: biceps brachii (BB), rectus femoris (RF), and tibialis anterior (TA) at rest measured by myoton device in males (n = 16, mean age 21.2 ± 0.6 years) and females (n = 16; 21.2 ± 0.9 years) and to...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Joanna Mencel, Anna Jaskólska, Jaroslaw Marusiak, Katarzyna Kisiel-Sajewicz, Magdalena Siemiatycka, Lukasz Kaminski, Artur Jaskólski
Formato: article
Lenguaje:EN
Publicado: PeerJ Inc. 2021
Materias:
R
Acceso en línea:https://doaj.org/article/61845b7e3f3a4627b58d82ea3c58a722
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:61845b7e3f3a4627b58d82ea3c58a722
record_format dspace
spelling oai:doaj.org-article:61845b7e3f3a4627b58d82ea3c58a7222021-11-12T15:05:12ZEffect of gender, muscle type and skinfold thickness on myometric parameters in young people10.7717/peerj.123672167-8359https://doaj.org/article/61845b7e3f3a4627b58d82ea3c58a7222021-11-01T00:00:00Zhttps://peerj.com/articles/12367.pdfhttps://peerj.com/articles/12367/https://doaj.org/toc/2167-8359Background The aim of the study was to compare the mechanical properties of three human skeletal muscles: biceps brachii (BB), rectus femoris (RF), and tibialis anterior (TA) at rest measured by myoton device in males (n = 16, mean age 21.2 ± 0.6 years) and females (n = 16; 21.2 ± 0.9 years) and to investigate the influence of skin and subcutaneous tissue thickness (skinfold thickness, SFT) and gender on myometric parameters of the three skeletal muscles. Methods We measured the following mechanical and viscoelastic muscle properties using MyotonPRO®: frequency (F [Hz]), decrement (D [log]), stiffness (S [N/m]), relaxation time (R [ms]) and creepability (C [De]). The values of SFT for all selected muscles were assessed by caliper. A mixed-design analysis of variance with gender as between subject comparison was used for assessing the differences between gender and muscles in SFT and each of the myometric parameters separately (F, D, S, R and C). Pearson correlation coefficient or Spearman’s rank correlation coefficient between SFT and myometric parameters was conducted for males, females and males and females together. The level of statistical significance was set at α ≤ 0.05 with Bonferroni correction for multiple comparisons. Results The SFT over the RF, TA, and BB muscles in women was statistically significantly larger compared with that of males. In females and males, the SFT over the RF was larger than over the TA and BB, and the SFT over the TA was larger compared with over the BB. The values of F and S recorded for the TA muscle were the highest among the three muscles, while D, C, and R were lowest in TA but highest in the RF muscle in men and women. The values of F and S were smaller in females than in males. Gender comparison of D, C, and R values showed that only D for the RF was significantly lower in females than in males, and C for the RF and TA was significantly larger in females than in males. Some correlation between SFT and myometric parameters were different between males and females. For example, there was a significant, negative correlation between SFT and F for all muscles in females, and a significant, positive correlation between these parameters for BB and TA (not for RF) in males. For pooled data (males and females together), a negative significant correlation between SFT and F was observed for RF and TA (not significant for BB muscle). Discussion It is concluded that the TA compared with the BB and RF has significantly greater F and S but the smallest D and C and the shortest R. Gender and muscle differences in the SFT may affect the measurements of muscle properties using MyotonPRO®. The relationship between SFT and myometric parameters is different in males and females in the RF, TA, and BB muscles. Therefore, the myometric data should be analyzed in males and females separately.Joanna MencelAnna JaskólskaJaroslaw MarusiakKatarzyna Kisiel-SajewiczMagdalena SiemiatyckaLukasz KaminskiArtur JaskólskiPeerJ Inc.articleSkinfoldMyotonViscoelasticityMethodologyGender differencesMechanical propertiesMedicineRENPeerJ, Vol 9, p e12367 (2021)
institution DOAJ
collection DOAJ
language EN
topic Skinfold
Myoton
Viscoelasticity
Methodology
Gender differences
Mechanical properties
Medicine
R
spellingShingle Skinfold
Myoton
Viscoelasticity
Methodology
Gender differences
Mechanical properties
Medicine
R
Joanna Mencel
Anna Jaskólska
Jaroslaw Marusiak
Katarzyna Kisiel-Sajewicz
Magdalena Siemiatycka
Lukasz Kaminski
Artur Jaskólski
Effect of gender, muscle type and skinfold thickness on myometric parameters in young people
description Background The aim of the study was to compare the mechanical properties of three human skeletal muscles: biceps brachii (BB), rectus femoris (RF), and tibialis anterior (TA) at rest measured by myoton device in males (n = 16, mean age 21.2 ± 0.6 years) and females (n = 16; 21.2 ± 0.9 years) and to investigate the influence of skin and subcutaneous tissue thickness (skinfold thickness, SFT) and gender on myometric parameters of the three skeletal muscles. Methods We measured the following mechanical and viscoelastic muscle properties using MyotonPRO®: frequency (F [Hz]), decrement (D [log]), stiffness (S [N/m]), relaxation time (R [ms]) and creepability (C [De]). The values of SFT for all selected muscles were assessed by caliper. A mixed-design analysis of variance with gender as between subject comparison was used for assessing the differences between gender and muscles in SFT and each of the myometric parameters separately (F, D, S, R and C). Pearson correlation coefficient or Spearman’s rank correlation coefficient between SFT and myometric parameters was conducted for males, females and males and females together. The level of statistical significance was set at α ≤ 0.05 with Bonferroni correction for multiple comparisons. Results The SFT over the RF, TA, and BB muscles in women was statistically significantly larger compared with that of males. In females and males, the SFT over the RF was larger than over the TA and BB, and the SFT over the TA was larger compared with over the BB. The values of F and S recorded for the TA muscle were the highest among the three muscles, while D, C, and R were lowest in TA but highest in the RF muscle in men and women. The values of F and S were smaller in females than in males. Gender comparison of D, C, and R values showed that only D for the RF was significantly lower in females than in males, and C for the RF and TA was significantly larger in females than in males. Some correlation between SFT and myometric parameters were different between males and females. For example, there was a significant, negative correlation between SFT and F for all muscles in females, and a significant, positive correlation between these parameters for BB and TA (not for RF) in males. For pooled data (males and females together), a negative significant correlation between SFT and F was observed for RF and TA (not significant for BB muscle). Discussion It is concluded that the TA compared with the BB and RF has significantly greater F and S but the smallest D and C and the shortest R. Gender and muscle differences in the SFT may affect the measurements of muscle properties using MyotonPRO®. The relationship between SFT and myometric parameters is different in males and females in the RF, TA, and BB muscles. Therefore, the myometric data should be analyzed in males and females separately.
format article
author Joanna Mencel
Anna Jaskólska
Jaroslaw Marusiak
Katarzyna Kisiel-Sajewicz
Magdalena Siemiatycka
Lukasz Kaminski
Artur Jaskólski
author_facet Joanna Mencel
Anna Jaskólska
Jaroslaw Marusiak
Katarzyna Kisiel-Sajewicz
Magdalena Siemiatycka
Lukasz Kaminski
Artur Jaskólski
author_sort Joanna Mencel
title Effect of gender, muscle type and skinfold thickness on myometric parameters in young people
title_short Effect of gender, muscle type and skinfold thickness on myometric parameters in young people
title_full Effect of gender, muscle type and skinfold thickness on myometric parameters in young people
title_fullStr Effect of gender, muscle type and skinfold thickness on myometric parameters in young people
title_full_unstemmed Effect of gender, muscle type and skinfold thickness on myometric parameters in young people
title_sort effect of gender, muscle type and skinfold thickness on myometric parameters in young people
publisher PeerJ Inc.
publishDate 2021
url https://doaj.org/article/61845b7e3f3a4627b58d82ea3c58a722
work_keys_str_mv AT joannamencel effectofgendermuscletypeandskinfoldthicknessonmyometricparametersinyoungpeople
AT annajaskolska effectofgendermuscletypeandskinfoldthicknessonmyometricparametersinyoungpeople
AT jaroslawmarusiak effectofgendermuscletypeandskinfoldthicknessonmyometricparametersinyoungpeople
AT katarzynakisielsajewicz effectofgendermuscletypeandskinfoldthicknessonmyometricparametersinyoungpeople
AT magdalenasiemiatycka effectofgendermuscletypeandskinfoldthicknessonmyometricparametersinyoungpeople
AT lukaszkaminski effectofgendermuscletypeandskinfoldthicknessonmyometricparametersinyoungpeople
AT arturjaskolski effectofgendermuscletypeandskinfoldthicknessonmyometricparametersinyoungpeople
_version_ 1718430372310548480