Evaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers

Alison YY Chan,1,2,* Jasmine C Chuang,1,2,* Victoria WY Wong1– 3 1Hong Kong Eye Hospital, Kowloon, Hong Kong; 2Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong; 3HKU Health System, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Chan AYY, Chuang JC, Wong VWY
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2021
Materias:
Acceso en línea:https://doaj.org/article/61b6d34fdf614d209a8397269c67efaa
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:61b6d34fdf614d209a8397269c67efaa
record_format dspace
spelling oai:doaj.org-article:61b6d34fdf614d209a8397269c67efaa2021-12-02T11:39:22ZEvaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers1177-5483https://doaj.org/article/61b6d34fdf614d209a8397269c67efaa2021-03-01T00:00:00Zhttps://www.dovepress.com/evaluation-of-meibomian-gland-dysfunction-among-ophthalmic-healthcare--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Alison YY Chan,1,2,* Jasmine C Chuang,1,2,* Victoria WY Wong1– 3 1Hong Kong Eye Hospital, Kowloon, Hong Kong; 2Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong; 3HKU Health System, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong*These authors contributed equally to this workCorrespondence: Victoria WY WongHKU Health System, Li Ka Shing Faculty of Medicine, University of Hong Kong, 21 Sassoon Road, Pokfulam, Hong KongEmail drvwong@hotmail.comPurpose: To evaluate the prevalence of meibomian gland dysfunction (MGD) among ophthalmic healthcare workers.Setting: A tertiary ophthalmic center.Design: Prospective, observational study.Methods: Forty-four volunteer ophthalmologists and ophthalmic nurses were recruited. Information including demographics, contact lens wear, history of refractive surgery and symptom score based on Standardized Patient Evaluation of Eye Dryness (SPEED) II Questionnaire for Dry Eye Disease/Ocular Surface Disease were recorded. Lipid layer thickness (LLT), meibomian glands dropout and dilation grades, and proportion of partial blinking were evaluated using an ocular surface interferometer with dynamic meibomian imaging (LipiView, Johnson & Johnson). Based on the chance of MGD, meibomian gland dropout and dilation, selected subjects also underwent treatment with a thermal pulsation system (LipiFlow, Johnson & Johnson) in one or both eyes.Results: Eighty-eight eyes of 44 volunteers were evaluated during the study period. The mean LLT was 60.0nm. Twenty-seven (61.4%) subjects had a 90% or high chance of MGD and their mean lower lid meibomian gland dropout and dilation grades were 1.2 and 1.7, respectively. Twenty-eight eyes of 16 volunteers received treatment with the thermal pulsation system. Following treatment, the mean LLT improved from 50.3nm to 61.0nm (Wilcoxon’s signed rank test, p=0.001).Conclusion: Despite being more knowledgeable to MGD and more accessible to treatment, MGD is a highly prevalent condition among ophthalmic healthcare workers, with a 61.4% prevalence among the recruited subjects. This is similar to reported prevalence in Asian populations of up to 74.5%. Targeted therapy based on dynamic meibomian imaging is effective in improving both objective and subjective measures of MGD.Keywords: meibomian gland dysfunction, lipid layer thickness, dynamic meibomian imaging, thermal pulsation systemChan AYYChuang JCWong VWYDove Medical Pressarticlemeibomian gland dysfunctionlipid layer thicknessdynamic meibomian imagingthermal pulsation systemOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 15, Pp 1201-1206 (2021)
institution DOAJ
collection DOAJ
language EN
topic meibomian gland dysfunction
lipid layer thickness
dynamic meibomian imaging
thermal pulsation system
Ophthalmology
RE1-994
spellingShingle meibomian gland dysfunction
lipid layer thickness
dynamic meibomian imaging
thermal pulsation system
Ophthalmology
RE1-994
Chan AYY
Chuang JC
Wong VWY
Evaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers
description Alison YY Chan,1,2,* Jasmine C Chuang,1,2,* Victoria WY Wong1– 3 1Hong Kong Eye Hospital, Kowloon, Hong Kong; 2Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong; 3HKU Health System, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong*These authors contributed equally to this workCorrespondence: Victoria WY WongHKU Health System, Li Ka Shing Faculty of Medicine, University of Hong Kong, 21 Sassoon Road, Pokfulam, Hong KongEmail drvwong@hotmail.comPurpose: To evaluate the prevalence of meibomian gland dysfunction (MGD) among ophthalmic healthcare workers.Setting: A tertiary ophthalmic center.Design: Prospective, observational study.Methods: Forty-four volunteer ophthalmologists and ophthalmic nurses were recruited. Information including demographics, contact lens wear, history of refractive surgery and symptom score based on Standardized Patient Evaluation of Eye Dryness (SPEED) II Questionnaire for Dry Eye Disease/Ocular Surface Disease were recorded. Lipid layer thickness (LLT), meibomian glands dropout and dilation grades, and proportion of partial blinking were evaluated using an ocular surface interferometer with dynamic meibomian imaging (LipiView, Johnson & Johnson). Based on the chance of MGD, meibomian gland dropout and dilation, selected subjects also underwent treatment with a thermal pulsation system (LipiFlow, Johnson & Johnson) in one or both eyes.Results: Eighty-eight eyes of 44 volunteers were evaluated during the study period. The mean LLT was 60.0nm. Twenty-seven (61.4%) subjects had a 90% or high chance of MGD and their mean lower lid meibomian gland dropout and dilation grades were 1.2 and 1.7, respectively. Twenty-eight eyes of 16 volunteers received treatment with the thermal pulsation system. Following treatment, the mean LLT improved from 50.3nm to 61.0nm (Wilcoxon’s signed rank test, p=0.001).Conclusion: Despite being more knowledgeable to MGD and more accessible to treatment, MGD is a highly prevalent condition among ophthalmic healthcare workers, with a 61.4% prevalence among the recruited subjects. This is similar to reported prevalence in Asian populations of up to 74.5%. Targeted therapy based on dynamic meibomian imaging is effective in improving both objective and subjective measures of MGD.Keywords: meibomian gland dysfunction, lipid layer thickness, dynamic meibomian imaging, thermal pulsation system
format article
author Chan AYY
Chuang JC
Wong VWY
author_facet Chan AYY
Chuang JC
Wong VWY
author_sort Chan AYY
title Evaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers
title_short Evaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers
title_full Evaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers
title_fullStr Evaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers
title_full_unstemmed Evaluation of Meibomian Gland Dysfunction Among Ophthalmic Healthcare Workers
title_sort evaluation of meibomian gland dysfunction among ophthalmic healthcare workers
publisher Dove Medical Press
publishDate 2021
url https://doaj.org/article/61b6d34fdf614d209a8397269c67efaa
work_keys_str_mv AT chanayy evaluationofmeibomianglanddysfunctionamongophthalmichealthcareworkers
AT chuangjc evaluationofmeibomianglanddysfunctionamongophthalmichealthcareworkers
AT wongvwy evaluationofmeibomianglanddysfunctionamongophthalmichealthcareworkers
_version_ 1718395702880501760