CoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-19

Abstract Accurate, reliable and rapid detection of SARS-CoV-2 is essential not only for correct diagnosis of individual COVID-19 disease but also for the development of a rational strategy aimed at lifting confinement restrictions and preparing for possible recurrent waves of viral infections. We ha...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Stephen Bustin, Amy Coward, Garry Sadler, Louise Teare, Tania Nolan
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
R
Q
Acceso en línea:https://doaj.org/article/61cde46ea3594d7aacd4dfe2fba6afbd
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:61cde46ea3594d7aacd4dfe2fba6afbd
record_format dspace
spelling oai:doaj.org-article:61cde46ea3594d7aacd4dfe2fba6afbd2021-12-02T12:03:14ZCoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-1910.1038/s41598-020-79233-x2045-2322https://doaj.org/article/61cde46ea3594d7aacd4dfe2fba6afbd2020-12-01T00:00:00Zhttps://doi.org/10.1038/s41598-020-79233-xhttps://doaj.org/toc/2045-2322Abstract Accurate, reliable and rapid detection of SARS-CoV-2 is essential not only for correct diagnosis of individual COVID-19 disease but also for the development of a rational strategy aimed at lifting confinement restrictions and preparing for possible recurrent waves of viral infections. We have used the MIQE guidelines to develop two versions of a unique five plex RT-qPCR test, termed CoV2-ID, that allows the detection of three viral target genes, a human internal control for confirming the presence of human cells in a sample and a control artificial RNA for quality assessment and potential quantification. Viral targets can be detected either individually with separate fluorophores or jointly using the same fluorophore, thus increasing the test’s reliability and sensitivity. It is robust, can consistently detect two copies of viral RNA, with a limit of detection of a single copy and can be completed in around 15 min. It was 100% sensitive and 100% specific when tested on 23 RNA samples extracted from COVID-19 positive patients and five COVID-19 negative patients. We also propose using multiple cycle fluorescence detection, rather than real-time PCR to reduce significantly the time taken to complete the assay as well as assuage the misunderstandings underlying the use of quantification cycles (Cq). Finally, we have designed an assay for the detection of the D614G mutation and show that all of the samples isolated in the Chelmsford, Essex area between mid-April and June 2020, have the mutant genotype whereas a sample originating in Australia was infected with the wild type genotype.Stephen BustinAmy CowardGarry SadlerLouise TeareTania NolanNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 10, Iss 1, Pp 1-13 (2020)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Stephen Bustin
Amy Coward
Garry Sadler
Louise Teare
Tania Nolan
CoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-19
description Abstract Accurate, reliable and rapid detection of SARS-CoV-2 is essential not only for correct diagnosis of individual COVID-19 disease but also for the development of a rational strategy aimed at lifting confinement restrictions and preparing for possible recurrent waves of viral infections. We have used the MIQE guidelines to develop two versions of a unique five plex RT-qPCR test, termed CoV2-ID, that allows the detection of three viral target genes, a human internal control for confirming the presence of human cells in a sample and a control artificial RNA for quality assessment and potential quantification. Viral targets can be detected either individually with separate fluorophores or jointly using the same fluorophore, thus increasing the test’s reliability and sensitivity. It is robust, can consistently detect two copies of viral RNA, with a limit of detection of a single copy and can be completed in around 15 min. It was 100% sensitive and 100% specific when tested on 23 RNA samples extracted from COVID-19 positive patients and five COVID-19 negative patients. We also propose using multiple cycle fluorescence detection, rather than real-time PCR to reduce significantly the time taken to complete the assay as well as assuage the misunderstandings underlying the use of quantification cycles (Cq). Finally, we have designed an assay for the detection of the D614G mutation and show that all of the samples isolated in the Chelmsford, Essex area between mid-April and June 2020, have the mutant genotype whereas a sample originating in Australia was infected with the wild type genotype.
format article
author Stephen Bustin
Amy Coward
Garry Sadler
Louise Teare
Tania Nolan
author_facet Stephen Bustin
Amy Coward
Garry Sadler
Louise Teare
Tania Nolan
author_sort Stephen Bustin
title CoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-19
title_short CoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-19
title_full CoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-19
title_fullStr CoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-19
title_full_unstemmed CoV2-ID, a MIQE-compliant sub-20-min 5-plex RT-PCR assay targeting SARS-CoV-2 for the diagnosis of COVID-19
title_sort cov2-id, a miqe-compliant sub-20-min 5-plex rt-pcr assay targeting sars-cov-2 for the diagnosis of covid-19
publisher Nature Portfolio
publishDate 2020
url https://doaj.org/article/61cde46ea3594d7aacd4dfe2fba6afbd
work_keys_str_mv AT stephenbustin cov2idamiqecompliantsub20min5plexrtpcrassaytargetingsarscov2forthediagnosisofcovid19
AT amycoward cov2idamiqecompliantsub20min5plexrtpcrassaytargetingsarscov2forthediagnosisofcovid19
AT garrysadler cov2idamiqecompliantsub20min5plexrtpcrassaytargetingsarscov2forthediagnosisofcovid19
AT louiseteare cov2idamiqecompliantsub20min5plexrtpcrassaytargetingsarscov2forthediagnosisofcovid19
AT tanianolan cov2idamiqecompliantsub20min5plexrtpcrassaytargetingsarscov2forthediagnosisofcovid19
_version_ 1718394750456823808