Development of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care

Angela Morejon,1 Agustin Mayo-Iscar,1,2 Raul Martin,1,3,4 Fernando Ussa1,5 1IOBA-Eye Institute, Universidad de Valladolid, Valladolid, Spain; 2Department of Statistics and Operational Research and IMUVA, Universidad de Valladolid, Valladolid, Spain; 3Department of Theoretical Physics, Atomic Physics...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Morejon A, Mayo-Iscar A, Martin R, Ussa F
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
PCA
Acceso en línea:https://doaj.org/article/63a97223d9f94d4c8f8db2d1098422ae
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:63a97223d9f94d4c8f8db2d1098422ae
record_format dspace
spelling oai:doaj.org-article:63a97223d9f94d4c8f8db2d1098422ae2021-12-02T04:39:03ZDevelopment of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care1177-5483https://doaj.org/article/63a97223d9f94d4c8f8db2d1098422ae2018-12-01T00:00:00Zhttps://www.dovepress.com/development-of-a-new-algorithm-based-on-fdt-matrix-perimetry-and-sd-oc-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Angela Morejon,1 Agustin Mayo-Iscar,1,2 Raul Martin,1,3,4 Fernando Ussa1,5 1IOBA-Eye Institute, Universidad de Valladolid, Valladolid, Spain; 2Department of Statistics and Operational Research and IMUVA, Universidad de Valladolid, Valladolid, Spain; 3Department of Theoretical Physics, Atomic Physics and Optics, Universidad de Valladolid, Valladolid, Spain; 4Faculty of Health and Human Sciences, Plymouth University, Plymouth, England, UK; 5Ophthalmology Department, The James Cook University Hospital, Middlesbrough, UK Purpose: The purpose of this study was to develop an objective algorithm to discriminate the earliest stages of glaucoma using frequency doubling technology (FDT) Matrix perimetry and spectral domain-optical coherence tomography (OCT) technology to improve primary care detection. Materials and methods: Three hundred six eyes (mean age 58.67±15.12) from 161 patients were included and classified in the following three groups: 101 nonglaucoma (GI-NG), 100 glaucoma suspect (GII-SG), and 105 open-angle glaucoma (GIII-OAG). All participants underwent a visual field exploration using the Humphrey Matrix visual field instrument and retinal nerve fiber layer evaluation using the Topcon 3D OCT-2000. Pattern deviation plot was divided into 19 areas and five aggrupation or quadrants and ranked with a value between 0 and 4 according to its likelihood of normality, and differences among three groups were analyzed. Principal component analysis (PCA) was also used to extract the most notable features of FDT and OCT, and a logistic regression analysis was applied to obtain the classification rules. Results: Only area numbers 7 and 12 and the central zone of FDT Matrix showed statistical differences (P<0.05) between GI-NG and GII-SG. The classification rules were estimated by the four PCA obtained from FDT Matrix and 3D OCT-2000 in a separate and combined use. Area under the receiver operating characteristic curve was 78.88% with FDT-PCA, 82.09% with OCT-PCA, and 94.27% with combined use of FDT and OCT-PCA to discriminate GI-NG and GII-SG. Conclusion: The predictive rules based on FDT-PCA or OCT-PCA provide a high sensitivity and specificity to detect the earliest stages of glaucoma and even better in combined use. These predictive rules may help the future development of software for FDT Matrix perimetry and 3D OCT-2000, which will greatly improve their diagnostic ability, making them useful in daily practice in a primary care setting. Keywords: FDT Matrix, 3D OCT-2000, PCA, glaucoma, primary careMorejon AMayo-Iscar AMartin RUssa FDove Medical PressarticleFDT MatrixOCT 3D 2000PCAglaucomaprimary careOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 33-42 (2018)
institution DOAJ
collection DOAJ
language EN
topic FDT Matrix
OCT 3D 2000
PCA
glaucoma
primary care
Ophthalmology
RE1-994
spellingShingle FDT Matrix
OCT 3D 2000
PCA
glaucoma
primary care
Ophthalmology
RE1-994
Morejon A
Mayo-Iscar A
Martin R
Ussa F
Development of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care
description Angela Morejon,1 Agustin Mayo-Iscar,1,2 Raul Martin,1,3,4 Fernando Ussa1,5 1IOBA-Eye Institute, Universidad de Valladolid, Valladolid, Spain; 2Department of Statistics and Operational Research and IMUVA, Universidad de Valladolid, Valladolid, Spain; 3Department of Theoretical Physics, Atomic Physics and Optics, Universidad de Valladolid, Valladolid, Spain; 4Faculty of Health and Human Sciences, Plymouth University, Plymouth, England, UK; 5Ophthalmology Department, The James Cook University Hospital, Middlesbrough, UK Purpose: The purpose of this study was to develop an objective algorithm to discriminate the earliest stages of glaucoma using frequency doubling technology (FDT) Matrix perimetry and spectral domain-optical coherence tomography (OCT) technology to improve primary care detection. Materials and methods: Three hundred six eyes (mean age 58.67±15.12) from 161 patients were included and classified in the following three groups: 101 nonglaucoma (GI-NG), 100 glaucoma suspect (GII-SG), and 105 open-angle glaucoma (GIII-OAG). All participants underwent a visual field exploration using the Humphrey Matrix visual field instrument and retinal nerve fiber layer evaluation using the Topcon 3D OCT-2000. Pattern deviation plot was divided into 19 areas and five aggrupation or quadrants and ranked with a value between 0 and 4 according to its likelihood of normality, and differences among three groups were analyzed. Principal component analysis (PCA) was also used to extract the most notable features of FDT and OCT, and a logistic regression analysis was applied to obtain the classification rules. Results: Only area numbers 7 and 12 and the central zone of FDT Matrix showed statistical differences (P<0.05) between GI-NG and GII-SG. The classification rules were estimated by the four PCA obtained from FDT Matrix and 3D OCT-2000 in a separate and combined use. Area under the receiver operating characteristic curve was 78.88% with FDT-PCA, 82.09% with OCT-PCA, and 94.27% with combined use of FDT and OCT-PCA to discriminate GI-NG and GII-SG. Conclusion: The predictive rules based on FDT-PCA or OCT-PCA provide a high sensitivity and specificity to detect the earliest stages of glaucoma and even better in combined use. These predictive rules may help the future development of software for FDT Matrix perimetry and 3D OCT-2000, which will greatly improve their diagnostic ability, making them useful in daily practice in a primary care setting. Keywords: FDT Matrix, 3D OCT-2000, PCA, glaucoma, primary care
format article
author Morejon A
Mayo-Iscar A
Martin R
Ussa F
author_facet Morejon A
Mayo-Iscar A
Martin R
Ussa F
author_sort Morejon A
title Development of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care
title_short Development of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care
title_full Development of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care
title_fullStr Development of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care
title_full_unstemmed Development of a new algorithm based on FDT Matrix perimetry and SD-OCT to improve early glaucoma detection in primary care
title_sort development of a new algorithm based on fdt matrix perimetry and sd-oct to improve early glaucoma detection in primary care
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/63a97223d9f94d4c8f8db2d1098422ae
work_keys_str_mv AT morejona developmentofanewalgorithmbasedonfdtmatrixperimetryandsdocttoimproveearlyglaucomadetectioninprimarycare
AT mayoiscara developmentofanewalgorithmbasedonfdtmatrixperimetryandsdocttoimproveearlyglaucomadetectioninprimarycare
AT martinr developmentofanewalgorithmbasedonfdtmatrixperimetryandsdocttoimproveearlyglaucomadetectioninprimarycare
AT ussaf developmentofanewalgorithmbasedonfdtmatrixperimetryandsdocttoimproveearlyglaucomadetectioninprimarycare
_version_ 1718401122824093696