Total Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory
BackgroundTotal laboratory automation (TLA) has the potential to reduce specimen processing time, optimize workflow, and decrease turnaround time (TAT). The purpose of this research is to investigate whether the TAT of our laboratory has changed since the adoption of TLA, as well as to optimize labo...
Guardado en:
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/64274963dafb4be2bd3e010b0fc341ed |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:64274963dafb4be2bd3e010b0fc341ed |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:64274963dafb4be2bd3e010b0fc341ed2021-12-02T11:46:35ZTotal Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory2235-298810.3389/fcimb.2021.765504https://doaj.org/article/64274963dafb4be2bd3e010b0fc341ed2021-12-01T00:00:00Zhttps://www.frontiersin.org/articles/10.3389/fcimb.2021.765504/fullhttps://doaj.org/toc/2235-2988BackgroundTotal laboratory automation (TLA) has the potential to reduce specimen processing time, optimize workflow, and decrease turnaround time (TAT). The purpose of this research is to investigate whether the TAT of our laboratory has changed since the adoption of TLA, as well as to optimize laboratory workflow, improve laboratory testing efficiency, and provide better services of clinical diagnosis and treatment.Materials and MethodsLaboratory data was extracted from our laboratory information system in two 6-month periods: pre-TLA (July to December 2019) and post-TLA (July to December 2020), respectively.ResultsThe median TAT for positive cultures decreased significantly from pre-TLA to post-TLA (65.93 vs 63.53, P<0.001). For different types of cultures, The TAT of CSF changed the most (86.76 vs 64.30, P=0.007), followed by sputum (64.38 vs 61.41, P<0.001), urine (52.10 vs 49,57, P<0.001), blood (68.49 vs 66.60, P<0.001). For Ascites and Pleural fluid, there was no significant difference (P>0.05). Further analysis found that the incidence of broth growth only for pre-TLA was 12.4% (14/133), while for post-TLA, it was 3.4% (4/119). The difference was statistically significant (P=0.01). The common isolates from CSF samples were Cryptococcus neoformans, coagulase-negative Staphylococcus, Acinetobacter baumannii, and Klebsiella pneumonia.ConclusionUsing TLA and setting up three shifts shortened the TAT of our clinical microbiology laboratory, especially for CSF samples.Weili ZhangSiying WuJin DengQuanfeng LiaoYa LiuLi XiongLing ShuYu YuanYuling XiaoYing MaMei KangDongdong LiYi XieFrontiers Media S.A.articletotal laboratory automationturnaround timeclinical microbiologyKiestraCSFMicrobiologyQR1-502ENFrontiers in Cellular and Infection Microbiology, Vol 11 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
total laboratory automation turnaround time clinical microbiology Kiestra CSF Microbiology QR1-502 |
spellingShingle |
total laboratory automation turnaround time clinical microbiology Kiestra CSF Microbiology QR1-502 Weili Zhang Siying Wu Jin Deng Quanfeng Liao Ya Liu Li Xiong Ling Shu Yu Yuan Yuling Xiao Ying Ma Mei Kang Dongdong Li Yi Xie Total Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory |
description |
BackgroundTotal laboratory automation (TLA) has the potential to reduce specimen processing time, optimize workflow, and decrease turnaround time (TAT). The purpose of this research is to investigate whether the TAT of our laboratory has changed since the adoption of TLA, as well as to optimize laboratory workflow, improve laboratory testing efficiency, and provide better services of clinical diagnosis and treatment.Materials and MethodsLaboratory data was extracted from our laboratory information system in two 6-month periods: pre-TLA (July to December 2019) and post-TLA (July to December 2020), respectively.ResultsThe median TAT for positive cultures decreased significantly from pre-TLA to post-TLA (65.93 vs 63.53, P<0.001). For different types of cultures, The TAT of CSF changed the most (86.76 vs 64.30, P=0.007), followed by sputum (64.38 vs 61.41, P<0.001), urine (52.10 vs 49,57, P<0.001), blood (68.49 vs 66.60, P<0.001). For Ascites and Pleural fluid, there was no significant difference (P>0.05). Further analysis found that the incidence of broth growth only for pre-TLA was 12.4% (14/133), while for post-TLA, it was 3.4% (4/119). The difference was statistically significant (P=0.01). The common isolates from CSF samples were Cryptococcus neoformans, coagulase-negative Staphylococcus, Acinetobacter baumannii, and Klebsiella pneumonia.ConclusionUsing TLA and setting up three shifts shortened the TAT of our clinical microbiology laboratory, especially for CSF samples. |
format |
article |
author |
Weili Zhang Siying Wu Jin Deng Quanfeng Liao Ya Liu Li Xiong Ling Shu Yu Yuan Yuling Xiao Ying Ma Mei Kang Dongdong Li Yi Xie |
author_facet |
Weili Zhang Siying Wu Jin Deng Quanfeng Liao Ya Liu Li Xiong Ling Shu Yu Yuan Yuling Xiao Ying Ma Mei Kang Dongdong Li Yi Xie |
author_sort |
Weili Zhang |
title |
Total Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory |
title_short |
Total Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory |
title_full |
Total Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory |
title_fullStr |
Total Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory |
title_full_unstemmed |
Total Laboratory Automation and Three Shifts Reduce Turnaround Time of Cerebrospinal Fluid Culture Results in the Chinese Clinical Microbiology Laboratory |
title_sort |
total laboratory automation and three shifts reduce turnaround time of cerebrospinal fluid culture results in the chinese clinical microbiology laboratory |
publisher |
Frontiers Media S.A. |
publishDate |
2021 |
url |
https://doaj.org/article/64274963dafb4be2bd3e010b0fc341ed |
work_keys_str_mv |
AT weilizhang totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT siyingwu totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT jindeng totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT quanfengliao totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT yaliu totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT lixiong totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT lingshu totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT yuyuan totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT yulingxiao totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT yingma totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT meikang totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT dongdongli totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory AT yixie totallaboratoryautomationandthreeshiftsreduceturnaroundtimeofcerebrospinalfluidcultureresultsinthechineseclinicalmicrobiologylaboratory |
_version_ |
1718395230815780864 |