Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light

Imaging Cherenkov emission during radiotherapy can provide information on the delivered radiation dose, but is attenuated by optical properties of the tissue. Here the authors derive a correction factor applicable to breast X-ray radiotherapy in human subjects to improve the correlation between Cher...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: R. L. Hachadorian, P. Bruza, M. Jermyn, D. J. Gladstone, B. W. Pogue, L. A. Jarvis
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2020
Materias:
Q
Acceso en línea:https://doaj.org/article/6436cb03709d4353872a69d6c1c2b2ab
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:6436cb03709d4353872a69d6c1c2b2ab
record_format dspace
spelling oai:doaj.org-article:6436cb03709d4353872a69d6c1c2b2ab2021-12-02T14:41:04ZImaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light10.1038/s41467-020-16031-z2041-1723https://doaj.org/article/6436cb03709d4353872a69d6c1c2b2ab2020-05-01T00:00:00Zhttps://doi.org/10.1038/s41467-020-16031-zhttps://doaj.org/toc/2041-1723Imaging Cherenkov emission during radiotherapy can provide information on the delivered radiation dose, but is attenuated by optical properties of the tissue. Here the authors derive a correction factor applicable to breast X-ray radiotherapy in human subjects to improve the correlation between Cherenkov emission intensity and dose.R. L. HachadorianP. BruzaM. JermynD. J. GladstoneB. W. PogueL. A. JarvisNature PortfolioarticleScienceQENNature Communications, Vol 11, Iss 1, Pp 1-9 (2020)
institution DOAJ
collection DOAJ
language EN
topic Science
Q
spellingShingle Science
Q
R. L. Hachadorian
P. Bruza
M. Jermyn
D. J. Gladstone
B. W. Pogue
L. A. Jarvis
Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
description Imaging Cherenkov emission during radiotherapy can provide information on the delivered radiation dose, but is attenuated by optical properties of the tissue. Here the authors derive a correction factor applicable to breast X-ray radiotherapy in human subjects to improve the correlation between Cherenkov emission intensity and dose.
format article
author R. L. Hachadorian
P. Bruza
M. Jermyn
D. J. Gladstone
B. W. Pogue
L. A. Jarvis
author_facet R. L. Hachadorian
P. Bruza
M. Jermyn
D. J. Gladstone
B. W. Pogue
L. A. Jarvis
author_sort R. L. Hachadorian
title Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
title_short Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
title_full Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
title_fullStr Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
title_full_unstemmed Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
title_sort imaging radiation dose in breast radiotherapy by x-ray ct calibration of cherenkov light
publisher Nature Portfolio
publishDate 2020
url https://doaj.org/article/6436cb03709d4353872a69d6c1c2b2ab
work_keys_str_mv AT rlhachadorian imagingradiationdoseinbreastradiotherapybyxrayctcalibrationofcherenkovlight
AT pbruza imagingradiationdoseinbreastradiotherapybyxrayctcalibrationofcherenkovlight
AT mjermyn imagingradiationdoseinbreastradiotherapybyxrayctcalibrationofcherenkovlight
AT djgladstone imagingradiationdoseinbreastradiotherapybyxrayctcalibrationofcherenkovlight
AT bwpogue imagingradiationdoseinbreastradiotherapybyxrayctcalibrationofcherenkovlight
AT lajarvis imagingradiationdoseinbreastradiotherapybyxrayctcalibrationofcherenkovlight
_version_ 1718390055323566080