Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study

Abstract Objectives The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoener...

Full description

Saved in:
Bibliographic Details
Main Authors: Juan Li, Yu-hong Wang, Fu-ling Zheng, Xin-yue Chen, Yun Lin, Cai-rong Zhu, Yi-fan Wu, Qiang Xu, Zheng-yu Jin, Hua-dan Xue
Format: article
Language:EN
Published: SpringerOpen 2021
Subjects:
Online Access:https://doaj.org/article/648a2fe412b6476d8f2b2966730a8d96
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:doaj.org-article:648a2fe412b6476d8f2b2966730a8d96
record_format dspace
spelling oai:doaj.org-article:648a2fe412b6476d8f2b2966730a8d962021-11-14T12:10:52ZFeasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study10.1186/s13244-021-01079-21869-4101https://doaj.org/article/648a2fe412b6476d8f2b2966730a8d962021-11-01T00:00:00Zhttps://doi.org/10.1186/s13244-021-01079-2https://doaj.org/toc/1869-4101Abstract Objectives The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging (VMI+) and high-concentration (400 mgI/mL) CM. Materials and methods 41 patients who underwent both normal dose CM (ND-CM, 320 mgI/kg) and low dose CM (LD-CM, 224 mgI/kg) thoracoabdominal enhanced CT for tumor follow-up were prospectively included. The VMI+ at the energy level of 40-kev for LD-CM images was reconstructed. CT attenuation, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of the abdominal artery, celiac artery, and superior mesenteric artery (SMA) and qualitative scores of pancreatic arteries depiction were recorded and compared among the three groups (ND-CM, LD-CM, and VMI+ LD-CM images). ANOVA and Friedman tests were used for statistical analysis. Results All quantitative and qualitative parameters on LD-CM images were lower than that on ND-CM images (all p < 0.01). There were no significant differences of all arteries’ qualitative scores between ND-CM and VMI+ LD-CM images (all p > 0.05). VMI+ LD-CM images had the highest mean CT and CNR values of all arteries (all p < 0.0001). The CM volume was 52.6 ± 9.4 mL for the ND-CM group and 37.0 ± 6.7 mL for the LD-CM group. Conclusion Ultra-low-dose CM (224 mgI/kg) was feasible for depicting pancreatic arteries. Inferior angiographic image quality could be successfully compensated by VMI+ and high-concentration CM.Juan LiYu-hong WangFu-ling ZhengXin-yue ChenYun LinCai-rong ZhuYi-fan WuQiang XuZheng-yu JinHua-dan XueSpringerOpenarticleComputed tomography angiographyPancreasArteriesContrast mediaMedical physics. Medical radiology. Nuclear medicineR895-920ENInsights into Imaging, Vol 12, Iss 1, Pp 1-11 (2021)
institution DOAJ
collection DOAJ
language EN
topic Computed tomography angiography
Pancreas
Arteries
Contrast media
Medical physics. Medical radiology. Nuclear medicine
R895-920
spellingShingle Computed tomography angiography
Pancreas
Arteries
Contrast media
Medical physics. Medical radiology. Nuclear medicine
R895-920
Juan Li
Yu-hong Wang
Fu-ling Zheng
Xin-yue Chen
Yun Lin
Cai-rong Zhu
Yi-fan Wu
Qiang Xu
Zheng-yu Jin
Hua-dan Xue
Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
description Abstract Objectives The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging (VMI+) and high-concentration (400 mgI/mL) CM. Materials and methods 41 patients who underwent both normal dose CM (ND-CM, 320 mgI/kg) and low dose CM (LD-CM, 224 mgI/kg) thoracoabdominal enhanced CT for tumor follow-up were prospectively included. The VMI+ at the energy level of 40-kev for LD-CM images was reconstructed. CT attenuation, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of the abdominal artery, celiac artery, and superior mesenteric artery (SMA) and qualitative scores of pancreatic arteries depiction were recorded and compared among the three groups (ND-CM, LD-CM, and VMI+ LD-CM images). ANOVA and Friedman tests were used for statistical analysis. Results All quantitative and qualitative parameters on LD-CM images were lower than that on ND-CM images (all p < 0.01). There were no significant differences of all arteries’ qualitative scores between ND-CM and VMI+ LD-CM images (all p > 0.05). VMI+ LD-CM images had the highest mean CT and CNR values of all arteries (all p < 0.0001). The CM volume was 52.6 ± 9.4 mL for the ND-CM group and 37.0 ± 6.7 mL for the LD-CM group. Conclusion Ultra-low-dose CM (224 mgI/kg) was feasible for depicting pancreatic arteries. Inferior angiographic image quality could be successfully compensated by VMI+ and high-concentration CM.
format article
author Juan Li
Yu-hong Wang
Fu-ling Zheng
Xin-yue Chen
Yun Lin
Cai-rong Zhu
Yi-fan Wu
Qiang Xu
Zheng-yu Jin
Hua-dan Xue
author_facet Juan Li
Yu-hong Wang
Fu-ling Zheng
Xin-yue Chen
Yun Lin
Cai-rong Zhu
Yi-fan Wu
Qiang Xu
Zheng-yu Jin
Hua-dan Xue
author_sort Juan Li
title Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_short Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_full Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_fullStr Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_full_unstemmed Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_sort feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
publisher SpringerOpen
publishDate 2021
url https://doaj.org/article/648a2fe412b6476d8f2b2966730a8d96
work_keys_str_mv AT juanli feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT yuhongwang feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT fulingzheng feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT xinyuechen feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT yunlin feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT cairongzhu feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT yifanwu feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT qiangxu feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT zhengyujin feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT huadanxue feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
_version_ 1718429407610142720