Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment

Khaled Alzahrani,1,2 Cristina Cristian,3 Sophie Harper,3 Fiona Carley,3 Arun Brahma,3 Debbie Morley,3 M Chantal Hillarby1 1Division of Pharmacy and Optometry, School of Health Sciences, University of Manchester, Manchester, UK; 2Ophthalmology Department, King Fahad Armed Forces Hospital, Jeddah, Sa...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Alzahrani K, Cristian C, Harper S, Carley F, Brahma A, Morley D, Hillarby MC
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://doaj.org/article/649820bc52b941b69cba6cde90a0c69a
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:649820bc52b941b69cba6cde90a0c69a
record_format dspace
spelling oai:doaj.org-article:649820bc52b941b69cba6cde90a0c69a2021-12-02T04:47:47ZCorneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment1177-5483https://doaj.org/article/649820bc52b941b69cba6cde90a0c69a2018-09-01T00:00:00Zhttps://www.dovepress.com/corneal-imaging-and-densitometry-measurements-in-keratoconus-patients--peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Khaled Alzahrani,1,2 Cristina Cristian,3 Sophie Harper,3 Fiona Carley,3 Arun Brahma,3 Debbie Morley,3 M Chantal Hillarby1 1Division of Pharmacy and Optometry, School of Health Sciences, University of Manchester, Manchester, UK; 2Ophthalmology Department, King Fahad Armed Forces Hospital, Jeddah, Saudi Arabia; 3Manchester Royal Eye Hospital, Manchester, UK Aim: The aim of this study was to compare the pre- and posttreatment corneal densitometry and corneal thickness value of keratoconus (KCN) patients managed via contact lenses (CLs) or by both intrastromal corneal rings and contact lenses.Patients and methods: This prospective study was performed at the Manchester Royal Eye Hospital, UK. Patients were recruited before treatment and followed up for 12 months. Data of corneal densitometry and corneal thickness were collected using the Oculus Pentacam at the pretreatment visit and posttreatment visit at 12 months.Results: Corneal clarity significantly differs between both groups at pre treatment at zone 0–2 mm for the anterior layer (P=0.002). The same diversity is present at zone 2–6 mm for the anterior layer (P=0.003) and posterior layer (P=0.008). The corneal clarity diversity found was not statistically significant at 12 months post treatment (P>0.05). Corneal thickness was found to be statistically significantly different between pre treatment and post treatment for the CL group for central corneal thickness (CCT) and thinnest area (P=0.01 and P=0.02), respectively.Discussion: This study shows that KCN management with Intacs was found to be effective in maintaining corneal clarity for a longer time than that with CL alone. On the other hand, corneal clarity reduces with disease progression in cases managed with CLs only. Analysis of Oculus Pentacam images provides an objective evaluation to monitor the corneal status after these different pathways of management. Keywords: keratoconus, contact lenses, densitometry, Intacs, keratocyte, hazeAlzahrani KCristian CHarper SCarley FBrahma AMorley DHillarby MCDove Medical PressarticleKeratoconusContact LensesDensitometryINTACSKeratocyteHazeOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 12, Pp 1653-1658 (2018)
institution DOAJ
collection DOAJ
language EN
topic Keratoconus
Contact Lenses
Densitometry
INTACS
Keratocyte
Haze
Ophthalmology
RE1-994
spellingShingle Keratoconus
Contact Lenses
Densitometry
INTACS
Keratocyte
Haze
Ophthalmology
RE1-994
Alzahrani K
Cristian C
Harper S
Carley F
Brahma A
Morley D
Hillarby MC
Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment
description Khaled Alzahrani,1,2 Cristina Cristian,3 Sophie Harper,3 Fiona Carley,3 Arun Brahma,3 Debbie Morley,3 M Chantal Hillarby1 1Division of Pharmacy and Optometry, School of Health Sciences, University of Manchester, Manchester, UK; 2Ophthalmology Department, King Fahad Armed Forces Hospital, Jeddah, Saudi Arabia; 3Manchester Royal Eye Hospital, Manchester, UK Aim: The aim of this study was to compare the pre- and posttreatment corneal densitometry and corneal thickness value of keratoconus (KCN) patients managed via contact lenses (CLs) or by both intrastromal corneal rings and contact lenses.Patients and methods: This prospective study was performed at the Manchester Royal Eye Hospital, UK. Patients were recruited before treatment and followed up for 12 months. Data of corneal densitometry and corneal thickness were collected using the Oculus Pentacam at the pretreatment visit and posttreatment visit at 12 months.Results: Corneal clarity significantly differs between both groups at pre treatment at zone 0–2 mm for the anterior layer (P=0.002). The same diversity is present at zone 2–6 mm for the anterior layer (P=0.003) and posterior layer (P=0.008). The corneal clarity diversity found was not statistically significant at 12 months post treatment (P>0.05). Corneal thickness was found to be statistically significantly different between pre treatment and post treatment for the CL group for central corneal thickness (CCT) and thinnest area (P=0.01 and P=0.02), respectively.Discussion: This study shows that KCN management with Intacs was found to be effective in maintaining corneal clarity for a longer time than that with CL alone. On the other hand, corneal clarity reduces with disease progression in cases managed with CLs only. Analysis of Oculus Pentacam images provides an objective evaluation to monitor the corneal status after these different pathways of management. Keywords: keratoconus, contact lenses, densitometry, Intacs, keratocyte, haze
format article
author Alzahrani K
Cristian C
Harper S
Carley F
Brahma A
Morley D
Hillarby MC
author_facet Alzahrani K
Cristian C
Harper S
Carley F
Brahma A
Morley D
Hillarby MC
author_sort Alzahrani K
title Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment
title_short Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment
title_full Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment
title_fullStr Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment
title_full_unstemmed Corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or Intacs treatment
title_sort corneal imaging and densitometry measurements in keratoconus patients to monitor disease progression and treatment outcomes after contact lens or intacs treatment
publisher Dove Medical Press
publishDate 2018
url https://doaj.org/article/649820bc52b941b69cba6cde90a0c69a
work_keys_str_mv AT alzahranik cornealimaginganddensitometrymeasurementsinkeratoconuspatientstomonitordiseaseprogressionandtreatmentoutcomesaftercontactlensorintacstreatment
AT cristianc cornealimaginganddensitometrymeasurementsinkeratoconuspatientstomonitordiseaseprogressionandtreatmentoutcomesaftercontactlensorintacstreatment
AT harpers cornealimaginganddensitometrymeasurementsinkeratoconuspatientstomonitordiseaseprogressionandtreatmentoutcomesaftercontactlensorintacstreatment
AT carleyf cornealimaginganddensitometrymeasurementsinkeratoconuspatientstomonitordiseaseprogressionandtreatmentoutcomesaftercontactlensorintacstreatment
AT brahmaa cornealimaginganddensitometrymeasurementsinkeratoconuspatientstomonitordiseaseprogressionandtreatmentoutcomesaftercontactlensorintacstreatment
AT morleyd cornealimaginganddensitometrymeasurementsinkeratoconuspatientstomonitordiseaseprogressionandtreatmentoutcomesaftercontactlensorintacstreatment
AT hillarbymc cornealimaginganddensitometrymeasurementsinkeratoconuspatientstomonitordiseaseprogressionandtreatmentoutcomesaftercontactlensorintacstreatment
_version_ 1718401008999071744