DETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS

Background. The aim of the article is to develop a methodology to determine parameters of three-element resonant electric circuits based on resonant frequency and quality factor measurements. Materials and methods. The proposed technique provides for the measurement of resonant frequency, quality...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: A.V. Svetlov, Ngoc Manh Nguyen
Formato: article
Lenguaje:EN
RU
Publicado: Penza State University Publishing House 2021
Materias:
Acceso en línea:https://doaj.org/article/650c308cc7974ba3bfbade30a872a690
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:650c308cc7974ba3bfbade30a872a690
record_format dspace
spelling oai:doaj.org-article:650c308cc7974ba3bfbade30a872a6902021-11-24T10:37:02ZDETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS10.21685/2307-5538-2021-3-52307-5538https://doaj.org/article/650c308cc7974ba3bfbade30a872a6902021-11-01T00:00:00Zhttps://doaj.org/toc/2307-5538Background. The aim of the article is to develop a methodology to determine parameters of three-element resonant electric circuits based on resonant frequency and quality factor measurements. Materials and methods. The proposed technique provides for the measurement of resonant frequency, quality factor, and maximum voltage at the output of a measuring circuit with subsequent solution of a system of equations connecting the measured parameters with inductance, capacitance, and active resistance of the electrical circuit. Results. Calculated ratios are given, and an example of determining the parameters of a specific three-element resonant electric circuit, and estimating the error component due to imperfection of an operational amplifier, with a measuring circuit built thereon, is considered. Conclusions. An application of the proposed technique to determine the parameters of resonant electrical circuits based on resonant frequency and quality factor measurements made it possible to get rid of errors in analogue conversions of the output voltage of the measuring circuit. According to the simulation results, the error component does not exceed 1 % due to imperfection of the element base of the measuring circuit.A.V. SvetlovNgoc Manh NguyenPenza State University Publishing Housearticleelectrical circuitresonant frequencyquality factorparameters of circuit elementsmeasurementerrorEngineering (General). Civil engineering (General)TA1-2040ENRUИзмерение, мониторинг, управление, контроль, Iss 3 (2021)
institution DOAJ
collection DOAJ
language EN
RU
topic electrical circuit
resonant frequency
quality factor
parameters of circuit elements
measurement
error
Engineering (General). Civil engineering (General)
TA1-2040
spellingShingle electrical circuit
resonant frequency
quality factor
parameters of circuit elements
measurement
error
Engineering (General). Civil engineering (General)
TA1-2040
A.V. Svetlov
Ngoc Manh Nguyen
DETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS
description Background. The aim of the article is to develop a methodology to determine parameters of three-element resonant electric circuits based on resonant frequency and quality factor measurements. Materials and methods. The proposed technique provides for the measurement of resonant frequency, quality factor, and maximum voltage at the output of a measuring circuit with subsequent solution of a system of equations connecting the measured parameters with inductance, capacitance, and active resistance of the electrical circuit. Results. Calculated ratios are given, and an example of determining the parameters of a specific three-element resonant electric circuit, and estimating the error component due to imperfection of an operational amplifier, with a measuring circuit built thereon, is considered. Conclusions. An application of the proposed technique to determine the parameters of resonant electrical circuits based on resonant frequency and quality factor measurements made it possible to get rid of errors in analogue conversions of the output voltage of the measuring circuit. According to the simulation results, the error component does not exceed 1 % due to imperfection of the element base of the measuring circuit.
format article
author A.V. Svetlov
Ngoc Manh Nguyen
author_facet A.V. Svetlov
Ngoc Manh Nguyen
author_sort A.V. Svetlov
title DETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS
title_short DETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS
title_full DETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS
title_fullStr DETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS
title_full_unstemmed DETERMINATION OF RESONANT ELECTRICAL CIRCUIT PARAMETERS BASED ON RESONANT FREQUENCY AND QUALITY FACTOR MEASUREMENTS
title_sort determination of resonant electrical circuit parameters based on resonant frequency and quality factor measurements
publisher Penza State University Publishing House
publishDate 2021
url https://doaj.org/article/650c308cc7974ba3bfbade30a872a690
work_keys_str_mv AT avsvetlov determinationofresonantelectricalcircuitparametersbasedonresonantfrequencyandqualityfactormeasurements
AT ngocmanhnguyen determinationofresonantelectricalcircuitparametersbasedonresonantfrequencyandqualityfactormeasurements
_version_ 1718415051036033024