Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume

Background and Objective: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased fetal movement or decrease o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: T Naderi, Y Nikian, F Amin Zadeh
Formato: article
Lenguaje:EN
FA
Publicado: Babol University of Medical Sciences 2002
Materias:
nst
R
Acceso en línea:https://doaj.org/article/657c064be45f46afa87b472639e89320
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:657c064be45f46afa87b472639e89320
record_format dspace
spelling oai:doaj.org-article:657c064be45f46afa87b472639e893202021-11-10T09:19:25ZSensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume1561-41072251-7170https://doaj.org/article/657c064be45f46afa87b472639e893202002-01-01T00:00:00Zhttp://jbums.org/article-1-2836-en.htmlhttps://doaj.org/toc/1561-4107https://doaj.org/toc/2251-7170Background and Objective: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased fetal movement or decrease of amniotic fluid volume according to sonography report. Methods: This cross-sectional study was done on 120 women referred to Bahonar hospital in Kerman. It was performed on all pregnant women with gestational age of 38-42 who complained of decrease of fetal movement (84.2%) and a decrease of amniotic fluid volume (61%) was reported in their sonography. Findings: The result of NST in 64.1% of patients was non-reactive and in 35.9% was reactive. 41.7% of cases were with fetal distress during labor or delivery, of which 94.1% had non-reactive NST. The sensitivity and specificity of NST in cases with decrease of amniotic fluid were 89% and 74.5%, respectively and in cases with complaint of decreased fetal movement were 63.4% and 32%, 7 respectively. Conclusion: Exact heart rate monitor in cases with complaint of decreased fetal movement or amniotic fluid volume and also with non-reactive NST in necessary.T NaderiY NikianF Amin ZadehBabol University of Medical Sciencesarticlenstfetal movementoligohydramniosMedicineRMedicine (General)R5-920ENFAMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul, Vol 4, Iss 1, Pp 7-10 (2002)
institution DOAJ
collection DOAJ
language EN
FA
topic nst
fetal movement
oligohydramnios
Medicine
R
Medicine (General)
R5-920
spellingShingle nst
fetal movement
oligohydramnios
Medicine
R
Medicine (General)
R5-920
T Naderi
Y Nikian
F Amin Zadeh
Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
description Background and Objective: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased fetal movement or decrease of amniotic fluid volume according to sonography report. Methods: This cross-sectional study was done on 120 women referred to Bahonar hospital in Kerman. It was performed on all pregnant women with gestational age of 38-42 who complained of decrease of fetal movement (84.2%) and a decrease of amniotic fluid volume (61%) was reported in their sonography. Findings: The result of NST in 64.1% of patients was non-reactive and in 35.9% was reactive. 41.7% of cases were with fetal distress during labor or delivery, of which 94.1% had non-reactive NST. The sensitivity and specificity of NST in cases with decrease of amniotic fluid were 89% and 74.5%, respectively and in cases with complaint of decreased fetal movement were 63.4% and 32%, 7 respectively. Conclusion: Exact heart rate monitor in cases with complaint of decreased fetal movement or amniotic fluid volume and also with non-reactive NST in necessary.
format article
author T Naderi
Y Nikian
F Amin Zadeh
author_facet T Naderi
Y Nikian
F Amin Zadeh
author_sort T Naderi
title Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_short Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_full Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_fullStr Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_full_unstemmed Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_sort sensitivity and specificity of nst in cases with decrease of fetal movement and amniotic fluid volume
publisher Babol University of Medical Sciences
publishDate 2002
url https://doaj.org/article/657c064be45f46afa87b472639e89320
work_keys_str_mv AT tnaderi sensitivityandspecificityofnstincaseswithdecreaseoffetalmovementandamnioticfluidvolume
AT ynikian sensitivityandspecificityofnstincaseswithdecreaseoffetalmovementandamnioticfluidvolume
AT faminzadeh sensitivityandspecificityofnstincaseswithdecreaseoffetalmovementandamnioticfluidvolume
_version_ 1718440106158718976