Islanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ

Distributed generation (DG) resources integration into power system results in environmental and economic benefits. However, technical challenges may create many problems for the distribution system. Islanding detection is the topmost technical perspective regarding distribution system protection. T...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Nouman Shafique, Safdar Raza, Hafiz Mudassir Munir, Syed Sabir Hussain Bukhari, Jong-Suk Ro
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
T
Acceso en línea:https://doaj.org/article/65dfa1f808ae4df7817d0a2420764eb9
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:65dfa1f808ae4df7817d0a2420764eb9
record_format dspace
spelling oai:doaj.org-article:65dfa1f808ae4df7817d0a2420764eb92021-11-11T15:04:31ZIslanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ10.3390/app112199892076-3417https://doaj.org/article/65dfa1f808ae4df7817d0a2420764eb92021-10-01T00:00:00Zhttps://www.mdpi.com/2076-3417/11/21/9989https://doaj.org/toc/2076-3417Distributed generation (DG) resources integration into power system results in environmental and economic benefits. However, technical challenges may create many problems for the distribution system. Islanding detection is the topmost technical perspective regarding distribution system protection. This paper devised a passive islanding detection strategy that employed voltage phase angle (VPA). The VPA is selected after the performance assessment of 6 passive indices. Comparative study proves that VPA has the best accuracy and sensitivity compared to other indices parameters. The proposed technique is employed on a generic system that easily distinguished islanding situations from non-islanding cases such as load increment, load decrement, capacitor energization, capacitor de-energization, motor starting, motor unloading and various types of faults switching scenarios. The protective method is simple and has a quick interpretation algorithm as compared to other existing methods. The study is carried out on IEEE 1547 general test system in MATLAB/SIMULINK environment. The proposed strategy has nearly zero non-detection zone.Nouman ShafiqueSafdar RazaHafiz Mudassir MunirSyed Sabir Hussain BukhariJong-Suk RoMDPI AGarticleislandingdistributed energy resources (DER’s)voltage phase angle (VPA)non-detection zone (NDZ)passive indicesTechnologyTEngineering (General). Civil engineering (General)TA1-2040Biology (General)QH301-705.5PhysicsQC1-999ChemistryQD1-999ENApplied Sciences, Vol 11, Iss 9989, p 9989 (2021)
institution DOAJ
collection DOAJ
language EN
topic islanding
distributed energy resources (DER’s)
voltage phase angle (VPA)
non-detection zone (NDZ)
passive indices
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Biology (General)
QH301-705.5
Physics
QC1-999
Chemistry
QD1-999
spellingShingle islanding
distributed energy resources (DER’s)
voltage phase angle (VPA)
non-detection zone (NDZ)
passive indices
Technology
T
Engineering (General). Civil engineering (General)
TA1-2040
Biology (General)
QH301-705.5
Physics
QC1-999
Chemistry
QD1-999
Nouman Shafique
Safdar Raza
Hafiz Mudassir Munir
Syed Sabir Hussain Bukhari
Jong-Suk Ro
Islanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ
description Distributed generation (DG) resources integration into power system results in environmental and economic benefits. However, technical challenges may create many problems for the distribution system. Islanding detection is the topmost technical perspective regarding distribution system protection. This paper devised a passive islanding detection strategy that employed voltage phase angle (VPA). The VPA is selected after the performance assessment of 6 passive indices. Comparative study proves that VPA has the best accuracy and sensitivity compared to other indices parameters. The proposed technique is employed on a generic system that easily distinguished islanding situations from non-islanding cases such as load increment, load decrement, capacitor energization, capacitor de-energization, motor starting, motor unloading and various types of faults switching scenarios. The protective method is simple and has a quick interpretation algorithm as compared to other existing methods. The study is carried out on IEEE 1547 general test system in MATLAB/SIMULINK environment. The proposed strategy has nearly zero non-detection zone.
format article
author Nouman Shafique
Safdar Raza
Hafiz Mudassir Munir
Syed Sabir Hussain Bukhari
Jong-Suk Ro
author_facet Nouman Shafique
Safdar Raza
Hafiz Mudassir Munir
Syed Sabir Hussain Bukhari
Jong-Suk Ro
author_sort Nouman Shafique
title Islanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ
title_short Islanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ
title_full Islanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ
title_fullStr Islanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ
title_full_unstemmed Islanding Detection Strategy for Wind Farm Based on Performance Analysis of Passive Indices Having Negligible NDZ
title_sort islanding detection strategy for wind farm based on performance analysis of passive indices having negligible ndz
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/65dfa1f808ae4df7817d0a2420764eb9
work_keys_str_mv AT noumanshafique islandingdetectionstrategyforwindfarmbasedonperformanceanalysisofpassiveindiceshavingnegligiblendz
AT safdarraza islandingdetectionstrategyforwindfarmbasedonperformanceanalysisofpassiveindiceshavingnegligiblendz
AT hafizmudassirmunir islandingdetectionstrategyforwindfarmbasedonperformanceanalysisofpassiveindiceshavingnegligiblendz
AT syedsabirhussainbukhari islandingdetectionstrategyforwindfarmbasedonperformanceanalysisofpassiveindiceshavingnegligiblendz
AT jongsukro islandingdetectionstrategyforwindfarmbasedonperformanceanalysisofpassiveindiceshavingnegligiblendz
_version_ 1718437144496701440