Axial length measurement acquisition rates of two optical biometers in cataractous eyes
Alice EpitropoulosThe Ohio State University Wexner Medical Center, Columbus, OH, USAPurpose: To compare the ability of two optical biometers to acquire the axial length (AL) measurement in cataractous eyes.Methods: This prospective, comparative, single-center study comprised 105 eyes (63 patients)....
Guardado en:
Autor principal: | |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2014
|
Materias: | |
Acceso en línea: | https://doaj.org/article/66462958d5c54dcd9c6c72c9fe1088b8 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:66462958d5c54dcd9c6c72c9fe1088b8 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:66462958d5c54dcd9c6c72c9fe1088b82021-12-02T02:54:56ZAxial length measurement acquisition rates of two optical biometers in cataractous eyes1177-5483https://doaj.org/article/66462958d5c54dcd9c6c72c9fe1088b82014-07-01T00:00:00Zhttp://www.dovepress.com/axial-length-measurement-acquisition-rates-of-two-optical-biometers-in-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483 Alice EpitropoulosThe Ohio State University Wexner Medical Center, Columbus, OH, USAPurpose: To compare the ability of two optical biometers to acquire the axial length (AL) measurement in cataractous eyes.Methods: This prospective, comparative, single-center study comprised 105 eyes (63 patients). AL was acquired by the composite mean value of 20 measurements (composite-20 IM) and five measurements (composite-5 IM) (IOLMaster® 500 version 7.1 software), and the standard mean value of the first five measurements (standard-5 LS, Lenstar LS 900®). Anterior chamber depth (ACD) and average keratometry (K) readings were acquired. Results: AL was acquired in 83.8%, 92.4%, and 84.8% of eyes for the composite-5 IM, composite-20 IM, and standard-5 LS, respectively. Standard-5 LS AL measurements were significantly shorter (P<0.001). IOLMaster® 500-acquired ACD (corneal epithelium to lens) measurements were significantly shorter (P<0.001). IOLMaster® 500 average K measurements were significantly steeper (P<0.001). Conclusion: The composite-20 IM had the highest AL acquisition success rate of the three versions evaluated. AL, ACD, and average Ks were statistically different between the two biometers, although the differences were clinically insignificant.Keywords: cataract, biometry, IOL power calculationEpitropoulos ADove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2014, Iss default, Pp 1369-1376 (2014) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Epitropoulos A Axial length measurement acquisition rates of two optical biometers in cataractous eyes |
description |
Alice EpitropoulosThe Ohio State University Wexner Medical Center, Columbus, OH, USAPurpose: To compare the ability of two optical biometers to acquire the axial length (AL) measurement in cataractous eyes.Methods: This prospective, comparative, single-center study comprised 105 eyes (63 patients). AL was acquired by the composite mean value of 20 measurements (composite-20 IM) and five measurements (composite-5 IM) (IOLMaster® 500 version 7.1 software), and the standard mean value of the first five measurements (standard-5 LS, Lenstar LS 900®). Anterior chamber depth (ACD) and average keratometry (K) readings were acquired. Results: AL was acquired in 83.8%, 92.4%, and 84.8% of eyes for the composite-5 IM, composite-20 IM, and standard-5 LS, respectively. Standard-5 LS AL measurements were significantly shorter (P<0.001). IOLMaster® 500-acquired ACD (corneal epithelium to lens) measurements were significantly shorter (P<0.001). IOLMaster® 500 average K measurements were significantly steeper (P<0.001). Conclusion: The composite-20 IM had the highest AL acquisition success rate of the three versions evaluated. AL, ACD, and average Ks were statistically different between the two biometers, although the differences were clinically insignificant.Keywords: cataract, biometry, IOL power calculation |
format |
article |
author |
Epitropoulos A |
author_facet |
Epitropoulos A |
author_sort |
Epitropoulos A |
title |
Axial length measurement acquisition rates of two optical biometers in cataractous eyes |
title_short |
Axial length measurement acquisition rates of two optical biometers in cataractous eyes |
title_full |
Axial length measurement acquisition rates of two optical biometers in cataractous eyes |
title_fullStr |
Axial length measurement acquisition rates of two optical biometers in cataractous eyes |
title_full_unstemmed |
Axial length measurement acquisition rates of two optical biometers in cataractous eyes |
title_sort |
axial length measurement acquisition rates of two optical biometers in cataractous eyes |
publisher |
Dove Medical Press |
publishDate |
2014 |
url |
https://doaj.org/article/66462958d5c54dcd9c6c72c9fe1088b8 |
work_keys_str_mv |
AT epitropoulosa axiallengthmeasurementacquisitionratesoftwoopticalbiometersincataractouseyes |
_version_ |
1718402044727918592 |