The Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan
Urban ventilation is being hampered by rough surfaces in dense urban areas, and the microclimate and air quality of the urban built environment are not ideal. Identifying urban ventilation paths is helpful to save energy, reduce emissions, and improve the urban ecological environment. Wuhan is the c...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/66c3b7dc5a1b471aa7bba5b2f77c05cd |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:66c3b7dc5a1b471aa7bba5b2f77c05cd |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:66c3b7dc5a1b471aa7bba5b2f77c05cd2021-11-11T16:46:16ZThe Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan10.3390/ijerph1821116841660-46011661-7827https://doaj.org/article/66c3b7dc5a1b471aa7bba5b2f77c05cd2021-11-01T00:00:00Zhttps://www.mdpi.com/1660-4601/18/21/11684https://doaj.org/toc/1661-7827https://doaj.org/toc/1660-4601Urban ventilation is being hampered by rough surfaces in dense urban areas, and the microclimate and air quality of the urban built environment are not ideal. Identifying urban ventilation paths is helpful to save energy, reduce emissions, and improve the urban ecological environment. Wuhan is the capital city of Hubei, and it has a high urban built intensity and hot summers. Taking Wuhan city, with a size of 35 km ×50 km, as an example, the built environment was divided into grids of 100 m × 100 m and included the building density, floor area ratio, and average building height. The ventilation mechanism of the urban built intensity index has previously been explained. The decrease in building density is not the sole factor causing an increase in wind speed; the enclosure and width of the ventilation path and the height of the front building are also influential. Twelve urban built units were selected for CFD numerical simulation. The ventilation efficiency of each grid was evaluated by calculating the wind speed ratio, maximum wind speed, average wind speed, and area ratio of strong wind. The relationship between the urban built intensity index and ventilation efficiency index was established using the factor analysis method and the Pearson correlation coefficient; building density and average building height are the most critical indexes of ventilation potential. In addition, the layout of the building also has an important impact on ventilation. A suitable built environment is that in which the building density is less than 30%, the average building height is greater than 15 m, and the floor area ratio is greater than 1.5. The urban built intensity map was weighted to identify urban ventilation paths. The paper provides a quantitative reference for scientific planning and design of the urban spatial form to improve ventilation.Jie YinQingming ZhanMuhammad TayyabAqeela ZahraMDPI AGarticleurban built intensity indexventilation efficiency indexventilation pathgeographic information system (GIS)computational fluid dynamics (CFD)MedicineRENInternational Journal of Environmental Research and Public Health, Vol 18, Iss 11684, p 11684 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
urban built intensity index ventilation efficiency index ventilation path geographic information system (GIS) computational fluid dynamics (CFD) Medicine R |
spellingShingle |
urban built intensity index ventilation efficiency index ventilation path geographic information system (GIS) computational fluid dynamics (CFD) Medicine R Jie Yin Qingming Zhan Muhammad Tayyab Aqeela Zahra The Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan |
description |
Urban ventilation is being hampered by rough surfaces in dense urban areas, and the microclimate and air quality of the urban built environment are not ideal. Identifying urban ventilation paths is helpful to save energy, reduce emissions, and improve the urban ecological environment. Wuhan is the capital city of Hubei, and it has a high urban built intensity and hot summers. Taking Wuhan city, with a size of 35 km ×50 km, as an example, the built environment was divided into grids of 100 m × 100 m and included the building density, floor area ratio, and average building height. The ventilation mechanism of the urban built intensity index has previously been explained. The decrease in building density is not the sole factor causing an increase in wind speed; the enclosure and width of the ventilation path and the height of the front building are also influential. Twelve urban built units were selected for CFD numerical simulation. The ventilation efficiency of each grid was evaluated by calculating the wind speed ratio, maximum wind speed, average wind speed, and area ratio of strong wind. The relationship between the urban built intensity index and ventilation efficiency index was established using the factor analysis method and the Pearson correlation coefficient; building density and average building height are the most critical indexes of ventilation potential. In addition, the layout of the building also has an important impact on ventilation. A suitable built environment is that in which the building density is less than 30%, the average building height is greater than 15 m, and the floor area ratio is greater than 1.5. The urban built intensity map was weighted to identify urban ventilation paths. The paper provides a quantitative reference for scientific planning and design of the urban spatial form to improve ventilation. |
format |
article |
author |
Jie Yin Qingming Zhan Muhammad Tayyab Aqeela Zahra |
author_facet |
Jie Yin Qingming Zhan Muhammad Tayyab Aqeela Zahra |
author_sort |
Jie Yin |
title |
The Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan |
title_short |
The Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan |
title_full |
The Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan |
title_fullStr |
The Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan |
title_full_unstemmed |
The Ventilation Efficiency of Urban Built Intensity and Ventilation Path Identification: A Case Study of Wuhan |
title_sort |
ventilation efficiency of urban built intensity and ventilation path identification: a case study of wuhan |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/66c3b7dc5a1b471aa7bba5b2f77c05cd |
work_keys_str_mv |
AT jieyin theventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan AT qingmingzhan theventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan AT muhammadtayyab theventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan AT aqeelazahra theventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan AT jieyin ventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan AT qingmingzhan ventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan AT muhammadtayyab ventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan AT aqeelazahra ventilationefficiencyofurbanbuiltintensityandventilationpathidentificationacasestudyofwuhan |
_version_ |
1718432243280510976 |