Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision

Jilin Tan,1,2 Yan Qin,2 Changpeng Wang,2 Shiman Yuan,2 Jian Ye11Department of Ophthalmology, Army Medical Center of PLA, Daping Hospital, Army Medical University, Chongqing 400042, People’s Republic of China; 2Cataract Department, Chongqing Aier Mega Eye Hospital, Chongqing 400060, People&...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Tan J, Qin Y, Wang C, Yuan S, Ye J
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://doaj.org/article/66cb818dce4841fd89a41ba5e4b6aaf7
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:66cb818dce4841fd89a41ba5e4b6aaf7
record_format dspace
spelling oai:doaj.org-article:66cb818dce4841fd89a41ba5e4b6aaf72021-12-02T03:18:22ZVisual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision1177-5483https://doaj.org/article/66cb818dce4841fd89a41ba5e4b6aaf72019-06-01T00:00:00Zhttps://www.dovepress.com/visual-quality-and-performance-following-bilateral-implantation-of-tec-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Jilin Tan,1,2 Yan Qin,2 Changpeng Wang,2 Shiman Yuan,2 Jian Ye11Department of Ophthalmology, Army Medical Center of PLA, Daping Hospital, Army Medical University, Chongqing 400042, People’s Republic of China; 2Cataract Department, Chongqing Aier Mega Eye Hospital, Chongqing 400060, People’s Republic of ChinaPurpose: To evaluate the visual quality and performance of TECNIS Symfony intraocular lenses (IOLs) implanted with or without micro-monovision approach.Setting: Chongqing Aier Mega Eye Hospital, Chongqing, China; Daping Hospital of Army Medical University, Chongqing, China.Design: Prospective study.Methods: The study comprised 70 cataract patients who had bilateral implantation of TECNIS Symfony extended range of vision IOLs, either with intended micro-monovision (monovision group: 35 patients) or with intended emmetropia (control group: 35 patients). Visual acuity, modulation transfer function (MTF), defocus curve, spectacle independence, and photic phenomena were analyzed 3 months postoperatively.Results: There was no significant difference between the two groups in binocular uncorrected visual acuity at distance. Mean binocular uncorrected visual acuity at intermediate (monovision: 0.81 dec; control: 0.58 dec) and near (monovision: 0.59 dec; control: 0.30 dec) were significantly better in the monovision group. In the monovision group, the difference of MTF values between the dominant and the non-dominant eyes was not statistically significant and MTF values were within the normal range for both eyes. Spectacle independence at intermediate and near was statistically significantly higher in the monovision group compared to the control group. The incidence of photic phenomena was similar in both groups.Conclusion: Micro-monovision implantation of TECNIS Symfony IOLs provided a superior range of visual acuity from far to near and higher spectacle independence compared to a control group targeted for emmetropia.Keywords: cataract, extended range of vision, defocus curve, spectacle independence, emmetropia, photic phenomenaTan JQin YWang CYuan SYe JDove Medical PressarticleTECNIS Symfonymicro-monovisiondefocus curvespectacle independencedominantOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 13, Pp 1071-1077 (2019)
institution DOAJ
collection DOAJ
language EN
topic TECNIS Symfony
micro-monovision
defocus curve
spectacle independence
dominant
Ophthalmology
RE1-994
spellingShingle TECNIS Symfony
micro-monovision
defocus curve
spectacle independence
dominant
Ophthalmology
RE1-994
Tan J
Qin Y
Wang C
Yuan S
Ye J
Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision
description Jilin Tan,1,2 Yan Qin,2 Changpeng Wang,2 Shiman Yuan,2 Jian Ye11Department of Ophthalmology, Army Medical Center of PLA, Daping Hospital, Army Medical University, Chongqing 400042, People’s Republic of China; 2Cataract Department, Chongqing Aier Mega Eye Hospital, Chongqing 400060, People’s Republic of ChinaPurpose: To evaluate the visual quality and performance of TECNIS Symfony intraocular lenses (IOLs) implanted with or without micro-monovision approach.Setting: Chongqing Aier Mega Eye Hospital, Chongqing, China; Daping Hospital of Army Medical University, Chongqing, China.Design: Prospective study.Methods: The study comprised 70 cataract patients who had bilateral implantation of TECNIS Symfony extended range of vision IOLs, either with intended micro-monovision (monovision group: 35 patients) or with intended emmetropia (control group: 35 patients). Visual acuity, modulation transfer function (MTF), defocus curve, spectacle independence, and photic phenomena were analyzed 3 months postoperatively.Results: There was no significant difference between the two groups in binocular uncorrected visual acuity at distance. Mean binocular uncorrected visual acuity at intermediate (monovision: 0.81 dec; control: 0.58 dec) and near (monovision: 0.59 dec; control: 0.30 dec) were significantly better in the monovision group. In the monovision group, the difference of MTF values between the dominant and the non-dominant eyes was not statistically significant and MTF values were within the normal range for both eyes. Spectacle independence at intermediate and near was statistically significantly higher in the monovision group compared to the control group. The incidence of photic phenomena was similar in both groups.Conclusion: Micro-monovision implantation of TECNIS Symfony IOLs provided a superior range of visual acuity from far to near and higher spectacle independence compared to a control group targeted for emmetropia.Keywords: cataract, extended range of vision, defocus curve, spectacle independence, emmetropia, photic phenomena
format article
author Tan J
Qin Y
Wang C
Yuan S
Ye J
author_facet Tan J
Qin Y
Wang C
Yuan S
Ye J
author_sort Tan J
title Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision
title_short Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision
title_full Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision
title_fullStr Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision
title_full_unstemmed Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision
title_sort visual quality and performance following bilateral implantation of tecnis symfony intraocular lenses with or without micro-monovision
publisher Dove Medical Press
publishDate 2019
url https://doaj.org/article/66cb818dce4841fd89a41ba5e4b6aaf7
work_keys_str_mv AT tanj visualqualityandperformancefollowingbilateralimplantationoftecnissymfonyintraocularlenseswithorwithoutmicromonovision
AT qiny visualqualityandperformancefollowingbilateralimplantationoftecnissymfonyintraocularlenseswithorwithoutmicromonovision
AT wangc visualqualityandperformancefollowingbilateralimplantationoftecnissymfonyintraocularlenseswithorwithoutmicromonovision
AT yuans visualqualityandperformancefollowingbilateralimplantationoftecnissymfonyintraocularlenseswithorwithoutmicromonovision
AT yej visualqualityandperformancefollowingbilateralimplantationoftecnissymfonyintraocularlenseswithorwithoutmicromonovision
_version_ 1718401796401004544