Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring
Ahmed Samir, Ayman M Abdelrahman Elsayed, Ahmed Alyan, Ayman Lotfy Ophthalmology Department, Zagazig University, Zagazig, EgyptCorrespondence: Ahmed SamirOphthalmology Department, Zagazig University, Zagazig, EgyptEmail ahmedsamir74@gmail.comPurpose: To describe a new technique for transconjunctival...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2020
|
Materias: | |
Acceso en línea: | https://doaj.org/article/670036fe751b4a4dbd2e076b0eb27047 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:670036fe751b4a4dbd2e076b0eb27047 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:670036fe751b4a4dbd2e076b0eb270472021-12-02T05:14:11ZDouble-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring1177-5483https://doaj.org/article/670036fe751b4a4dbd2e076b0eb270472020-04-01T00:00:00Zhttps://www.dovepress.com/double-flanged-polypropylene-suture-for-scleral-fixation-of-cionni-cap-peer-reviewed-article-OPTHhttps://doaj.org/toc/1177-5483Ahmed Samir, Ayman M Abdelrahman Elsayed, Ahmed Alyan, Ayman Lotfy Ophthalmology Department, Zagazig University, Zagazig, EgyptCorrespondence: Ahmed SamirOphthalmology Department, Zagazig University, Zagazig, EgyptEmail ahmedsamir74@gmail.comPurpose: To describe a new technique for transconjunctival intrascleral fixation of Cionni CTR using double-flanged polypropylens suture.Methods: This is a prospective interventional case series which included 7 cases with severe (more than 180 degrees) zonular dialysis. Three cases were hereditary lens subluxation (Marfan syndrome), 2 cases with traumatic subluxation and 2 cases with pseudo-exfoliation syndrome.Results: All cases achieved a good postoperative stable and centered IOL with good visual results. No postoperative complications were recorded apart from PCO in 3 cases and mild bleeding during needle passage in one case.Conclusion: This described technique is a simple, time sparing and minimally invasive method for achieving good bag centration. It eliminates the need of conjunctival peritomy, subconjunctival vessels cautery and scleral fashioning of a flap, pocket or a groove. The use of 6/0 polypropylene theoretically can achieve better longevity.Keywords: Cionni ring, lens subluxation, polypropylene suture, scleral fixationSamir AAbdelrahman Elsayed AMAlyan ALotfy ADove Medical Pressarticle1) cionni ring 2) lens subluxation 3) prolene suture 4) scleral fixationOphthalmologyRE1-994ENClinical Ophthalmology, Vol Volume 14, Pp 1055-1058 (2020) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
1) cionni ring 2) lens subluxation 3) prolene suture 4) scleral fixation Ophthalmology RE1-994 |
spellingShingle |
1) cionni ring 2) lens subluxation 3) prolene suture 4) scleral fixation Ophthalmology RE1-994 Samir A Abdelrahman Elsayed AM Alyan A Lotfy A Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring |
description |
Ahmed Samir, Ayman M Abdelrahman Elsayed, Ahmed Alyan, Ayman Lotfy Ophthalmology Department, Zagazig University, Zagazig, EgyptCorrespondence: Ahmed SamirOphthalmology Department, Zagazig University, Zagazig, EgyptEmail ahmedsamir74@gmail.comPurpose: To describe a new technique for transconjunctival intrascleral fixation of Cionni CTR using double-flanged polypropylens suture.Methods: This is a prospective interventional case series which included 7 cases with severe (more than 180 degrees) zonular dialysis. Three cases were hereditary lens subluxation (Marfan syndrome), 2 cases with traumatic subluxation and 2 cases with pseudo-exfoliation syndrome.Results: All cases achieved a good postoperative stable and centered IOL with good visual results. No postoperative complications were recorded apart from PCO in 3 cases and mild bleeding during needle passage in one case.Conclusion: This described technique is a simple, time sparing and minimally invasive method for achieving good bag centration. It eliminates the need of conjunctival peritomy, subconjunctival vessels cautery and scleral fashioning of a flap, pocket or a groove. The use of 6/0 polypropylene theoretically can achieve better longevity.Keywords: Cionni ring, lens subluxation, polypropylene suture, scleral fixation |
format |
article |
author |
Samir A Abdelrahman Elsayed AM Alyan A Lotfy A |
author_facet |
Samir A Abdelrahman Elsayed AM Alyan A Lotfy A |
author_sort |
Samir A |
title |
Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring |
title_short |
Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring |
title_full |
Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring |
title_fullStr |
Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring |
title_full_unstemmed |
Double-Flanged polypropylene Suture for Scleral Fixation of Cionni Capsule Tension Ring |
title_sort |
double-flanged polypropylene suture for scleral fixation of cionni capsule tension ring |
publisher |
Dove Medical Press |
publishDate |
2020 |
url |
https://doaj.org/article/670036fe751b4a4dbd2e076b0eb27047 |
work_keys_str_mv |
AT samira doubleflangedpolypropylenesutureforscleralfixationofcionnicapsuletensionring AT abdelrahmanelsayedam doubleflangedpolypropylenesutureforscleralfixationofcionnicapsuletensionring AT alyana doubleflangedpolypropylenesutureforscleralfixationofcionnicapsuletensionring AT lotfya doubleflangedpolypropylenesutureforscleralfixationofcionnicapsuletensionring |
_version_ |
1718400474389938176 |