Biosafety Level 3 setup for multiphoton microscopy in vivo

Abstract Multiphoton microscopy has revealed important insights into cellular behavior in vivo. However, its application in infectious settings often encounters technical, safety and regulatory limitations that prevent its wider use with highly virulent human pathogens. Herein, we present a method t...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: D. Barlerin, G. Bessière, J. Domingues, M. Schuette, C. Feuillet, A. Peixoto
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/677b26d08e474fa7b841377f8d85bc21
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:677b26d08e474fa7b841377f8d85bc21
record_format dspace
spelling oai:doaj.org-article:677b26d08e474fa7b841377f8d85bc212021-12-02T15:05:38ZBiosafety Level 3 setup for multiphoton microscopy in vivo10.1038/s41598-017-00702-x2045-2322https://doaj.org/article/677b26d08e474fa7b841377f8d85bc212017-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-00702-xhttps://doaj.org/toc/2045-2322Abstract Multiphoton microscopy has revealed important insights into cellular behavior in vivo. However, its application in infectious settings often encounters technical, safety and regulatory limitations that prevent its wider use with highly virulent human pathogens. Herein, we present a method that renders multiphoton microscopy in vivo compatible with biosafety level 3 regulations and present an example of its application and potential to visualize a Mycobacterium tuberculosis infection of the mouse lung.D. BarlerinG. BessièreJ. DominguesM. SchuetteC. FeuilletA. PeixotoNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-10 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
D. Barlerin
G. Bessière
J. Domingues
M. Schuette
C. Feuillet
A. Peixoto
Biosafety Level 3 setup for multiphoton microscopy in vivo
description Abstract Multiphoton microscopy has revealed important insights into cellular behavior in vivo. However, its application in infectious settings often encounters technical, safety and regulatory limitations that prevent its wider use with highly virulent human pathogens. Herein, we present a method that renders multiphoton microscopy in vivo compatible with biosafety level 3 regulations and present an example of its application and potential to visualize a Mycobacterium tuberculosis infection of the mouse lung.
format article
author D. Barlerin
G. Bessière
J. Domingues
M. Schuette
C. Feuillet
A. Peixoto
author_facet D. Barlerin
G. Bessière
J. Domingues
M. Schuette
C. Feuillet
A. Peixoto
author_sort D. Barlerin
title Biosafety Level 3 setup for multiphoton microscopy in vivo
title_short Biosafety Level 3 setup for multiphoton microscopy in vivo
title_full Biosafety Level 3 setup for multiphoton microscopy in vivo
title_fullStr Biosafety Level 3 setup for multiphoton microscopy in vivo
title_full_unstemmed Biosafety Level 3 setup for multiphoton microscopy in vivo
title_sort biosafety level 3 setup for multiphoton microscopy in vivo
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/677b26d08e474fa7b841377f8d85bc21
work_keys_str_mv AT dbarlerin biosafetylevel3setupformultiphotonmicroscopyinvivo
AT gbessiere biosafetylevel3setupformultiphotonmicroscopyinvivo
AT jdomingues biosafetylevel3setupformultiphotonmicroscopyinvivo
AT mschuette biosafetylevel3setupformultiphotonmicroscopyinvivo
AT cfeuillet biosafetylevel3setupformultiphotonmicroscopyinvivo
AT apeixoto biosafetylevel3setupformultiphotonmicroscopyinvivo
_version_ 1718388769251393536