Direct protein quantification in complex sample solutions by surface-engineered nanorod probes

Abstract Detecting biomarkers from complex sample solutions is the key objective of molecular diagnostics. Being able to do so in a simple approach that does not require laborious sample preparation, sophisticated equipment and trained staff is vital for point-of-care applications. Here, we report o...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Stefan Schrittwieser, Beatriz Pelaz, Wolfgang J. Parak, Sergio Lentijo-Mozo, Katerina Soulantica, Jan Dieckhoff, Frank Ludwig, Joerg Schotter
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/6793f75d1efd4175acfff301ea6d47a0
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:6793f75d1efd4175acfff301ea6d47a0
record_format dspace
spelling oai:doaj.org-article:6793f75d1efd4175acfff301ea6d47a02021-12-02T16:06:27ZDirect protein quantification in complex sample solutions by surface-engineered nanorod probes10.1038/s41598-017-04970-52045-2322https://doaj.org/article/6793f75d1efd4175acfff301ea6d47a02017-07-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-04970-5https://doaj.org/toc/2045-2322Abstract Detecting biomarkers from complex sample solutions is the key objective of molecular diagnostics. Being able to do so in a simple approach that does not require laborious sample preparation, sophisticated equipment and trained staff is vital for point-of-care applications. Here, we report on the specific detection of the breast cancer biomarker sHER2 directly from serum and saliva samples by a nanorod-based homogeneous biosensing approach, which is easy to operate as it only requires mixing of the samples with the nanorod probes. By careful nanorod surface engineering and homogeneous assay design, we demonstrate that the formation of a protein corona around the nanoparticles does not limit the applicability of our detection method, but on the contrary enables us to conduct in-situ reference measurements, thus further strengthening the point-of-care applicability of our method. Making use of sandwich assays on top of the nanorods, we obtain a limit of detection of 110 pM and 470 pM in 10-fold diluted spiked saliva and serum samples, respectively. In conclusion, our results open up numerous applications in direct protein biomarker quantification, specifically in point-of-care settings where resources are limited and ease-of-use is of essence.Stefan SchrittwieserBeatriz PelazWolfgang J. ParakSergio Lentijo-MozoKaterina SoulanticaJan DieckhoffFrank LudwigJoerg SchotterNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-6 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Stefan Schrittwieser
Beatriz Pelaz
Wolfgang J. Parak
Sergio Lentijo-Mozo
Katerina Soulantica
Jan Dieckhoff
Frank Ludwig
Joerg Schotter
Direct protein quantification in complex sample solutions by surface-engineered nanorod probes
description Abstract Detecting biomarkers from complex sample solutions is the key objective of molecular diagnostics. Being able to do so in a simple approach that does not require laborious sample preparation, sophisticated equipment and trained staff is vital for point-of-care applications. Here, we report on the specific detection of the breast cancer biomarker sHER2 directly from serum and saliva samples by a nanorod-based homogeneous biosensing approach, which is easy to operate as it only requires mixing of the samples with the nanorod probes. By careful nanorod surface engineering and homogeneous assay design, we demonstrate that the formation of a protein corona around the nanoparticles does not limit the applicability of our detection method, but on the contrary enables us to conduct in-situ reference measurements, thus further strengthening the point-of-care applicability of our method. Making use of sandwich assays on top of the nanorods, we obtain a limit of detection of 110 pM and 470 pM in 10-fold diluted spiked saliva and serum samples, respectively. In conclusion, our results open up numerous applications in direct protein biomarker quantification, specifically in point-of-care settings where resources are limited and ease-of-use is of essence.
format article
author Stefan Schrittwieser
Beatriz Pelaz
Wolfgang J. Parak
Sergio Lentijo-Mozo
Katerina Soulantica
Jan Dieckhoff
Frank Ludwig
Joerg Schotter
author_facet Stefan Schrittwieser
Beatriz Pelaz
Wolfgang J. Parak
Sergio Lentijo-Mozo
Katerina Soulantica
Jan Dieckhoff
Frank Ludwig
Joerg Schotter
author_sort Stefan Schrittwieser
title Direct protein quantification in complex sample solutions by surface-engineered nanorod probes
title_short Direct protein quantification in complex sample solutions by surface-engineered nanorod probes
title_full Direct protein quantification in complex sample solutions by surface-engineered nanorod probes
title_fullStr Direct protein quantification in complex sample solutions by surface-engineered nanorod probes
title_full_unstemmed Direct protein quantification in complex sample solutions by surface-engineered nanorod probes
title_sort direct protein quantification in complex sample solutions by surface-engineered nanorod probes
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/6793f75d1efd4175acfff301ea6d47a0
work_keys_str_mv AT stefanschrittwieser directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
AT beatrizpelaz directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
AT wolfgangjparak directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
AT sergiolentijomozo directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
AT katerinasoulantica directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
AT jandieckhoff directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
AT frankludwig directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
AT joergschotter directproteinquantificationincomplexsamplesolutionsbysurfaceengineerednanorodprobes
_version_ 1718384964373839872