Diffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements
Insufficient diffuseness is the major cause of the poor repeatability and reproducibility of building acoustical measurements in a reverberation chamber. Inaccurate results were reported for the prevailing methods in ISO and ASTM standards. Many previous studies, thus, have proposed new methods to q...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
MDPI AG
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/67c509e4ebf84b249f91dad88ac7dc3c |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:67c509e4ebf84b249f91dad88ac7dc3c |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:67c509e4ebf84b249f91dad88ac7dc3c2021-11-25T16:59:43ZDiffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements10.3390/buildings111105192075-5309https://doaj.org/article/67c509e4ebf84b249f91dad88ac7dc3c2021-11-01T00:00:00Zhttps://www.mdpi.com/2075-5309/11/11/519https://doaj.org/toc/2075-5309Insufficient diffuseness is the major cause of the poor repeatability and reproducibility of building acoustical measurements in a reverberation chamber. Inaccurate results were reported for the prevailing methods in ISO and ASTM standards. Many previous studies, thus, have proposed new methods to quantify the diffuseness of a reverberation chamber more accurately, but there is no general agreement among researchers on the most reliable method. The number of measurement samples required for these diffuseness metrics is also unclear, even though it significantly impacts the robustness of the methods. This study, therefore, aims to compare the performance of the two widely used diffuseness metrics (spatial variation of sound pressure levels and the relative standard deviation of decay rates) in the standards and the recently introduced metric (degree of time series fluctuation). The measurements were carried out with fine resolution microphone positions and varied configurations of acoustic diffusers. The degree of time series fluctuation showed the best correlation with varying diffuser configurations in the low-frequency range. Confidence intervals and coefficients of variation of the three metrics by random sampling also indicated that DTF is more reliable for evaluating the diffuseness in a sound field as it is less influenced by the number of sampling.Shuying ZhangJoonhee LeeMDPI AGarticlereverberation chamberdiffuseness quantificationmeasurement samplingBuilding constructionTH1-9745ENBuildings, Vol 11, Iss 519, p 519 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
reverberation chamber diffuseness quantification measurement sampling Building construction TH1-9745 |
spellingShingle |
reverberation chamber diffuseness quantification measurement sampling Building construction TH1-9745 Shuying Zhang Joonhee Lee Diffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements |
description |
Insufficient diffuseness is the major cause of the poor repeatability and reproducibility of building acoustical measurements in a reverberation chamber. Inaccurate results were reported for the prevailing methods in ISO and ASTM standards. Many previous studies, thus, have proposed new methods to quantify the diffuseness of a reverberation chamber more accurately, but there is no general agreement among researchers on the most reliable method. The number of measurement samples required for these diffuseness metrics is also unclear, even though it significantly impacts the robustness of the methods. This study, therefore, aims to compare the performance of the two widely used diffuseness metrics (spatial variation of sound pressure levels and the relative standard deviation of decay rates) in the standards and the recently introduced metric (degree of time series fluctuation). The measurements were carried out with fine resolution microphone positions and varied configurations of acoustic diffusers. The degree of time series fluctuation showed the best correlation with varying diffuser configurations in the low-frequency range. Confidence intervals and coefficients of variation of the three metrics by random sampling also indicated that DTF is more reliable for evaluating the diffuseness in a sound field as it is less influenced by the number of sampling. |
format |
article |
author |
Shuying Zhang Joonhee Lee |
author_facet |
Shuying Zhang Joonhee Lee |
author_sort |
Shuying Zhang |
title |
Diffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements |
title_short |
Diffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements |
title_full |
Diffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements |
title_fullStr |
Diffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements |
title_full_unstemmed |
Diffuseness Quantification in a Reverberation Chamber and Its Variation with Fine-Resolution Measurements |
title_sort |
diffuseness quantification in a reverberation chamber and its variation with fine-resolution measurements |
publisher |
MDPI AG |
publishDate |
2021 |
url |
https://doaj.org/article/67c509e4ebf84b249f91dad88ac7dc3c |
work_keys_str_mv |
AT shuyingzhang diffusenessquantificationinareverberationchamberanditsvariationwithfineresolutionmeasurements AT joonheelee diffusenessquantificationinareverberationchamberanditsvariationwithfineresolutionmeasurements |
_version_ |
1718412779675713536 |