THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN

Introduction. Reliability of high voltage power cables in the process of long-term operation is largely due to the intensity of polymeric insulation aging. It is now established that the aging of polyethylene, which is the main material for the insulation of high voltage power cables, under the acti...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: G. V. Bezprozvannych, A. G. Kyessayev
Formato: article
Lenguaje:EN
RU
UK
Publicado: National Technical University "Kharkiv Polytechnic Institute" 2016
Materias:
Acceso en línea:https://doaj.org/article/67e57997d5f64075b26f238ba2831bb4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:67e57997d5f64075b26f238ba2831bb4
record_format dspace
spelling oai:doaj.org-article:67e57997d5f64075b26f238ba2831bb42021-12-02T15:09:35ZTHE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN10.20998/2074-272X.2016.6.092074-272X2309-3404https://doaj.org/article/67e57997d5f64075b26f238ba2831bb42016-12-01T00:00:00Zhttp://eie.khpi.edu.ua/article/view/2074-272X.2016.6.09/82189https://doaj.org/toc/2074-272Xhttps://doaj.org/toc/2309-3404Introduction. Reliability of high voltage power cables in the process of long-term operation is largely due to the intensity of polymeric insulation aging. It is now established that the aging of polyethylene, which is the main material for the insulation of high voltage power cables, under the action of the electric field is determined primarily by the presence of structural heterogeneity arising both during cable production and during use. The cable is always there deviations from the ideal structure, which manifest in a deviation of diameters of conductors from nominal values; in the arrangement of the conductor and the insulation is not strictly coaxially and eccentrically; in elliptic (oval) core and insulation; change in relative dielectric constant and thickness of insulation on cable length force the formation of low molecular weight products (including water) in the flow at the manufacturing stage crosslinked polyethylene insulation and moisture during operation. Such defects are structural, technological and operational irregularities, which lead to a local change in the electric field. Purpose. Analysis of the influence of the eccentricity, elliptic and spherical inclusions in the electric field distribution in the power cable of a coaxial design with cross-linked polyethylene insulation, based on numerical simulation. Methodology. The bases of the numerical method of calculation of the electrical field strength are Fredholm integral equations of the first and second kind (method of secondary sources) for an axially symmetric field. Analysis of the influence of irregularities, including water treeing, the shape of the sounding signal is made using the method of discrete resistive circuit inductance and capacitance of substitution with the initial conditions. Solving systems of linear algebraic equations nodal analysis performed by the sweep method. Results. The presence of the eccentricity and ellipticity in the construction of cable has different effects on the distribution of the electrical field strength at the conductor and the insulation. The electrical field strength is increased by 50 % in the core and 17 % - on the surface of the insulation at 10 % eccentricity between conductor and insulation. Availability elliptic insulation leads to a redistribution of the electric field: field strength at the surface of the insulation is 2 times higher electric field strength on the surface of the conductor. Water treeing spherical shape filled with water with a dielectric constant of 6.9, lead to a local increase of electric field intensity is 5 - 10 times. Originality. Simulation results show that the presence of water treeing concentrated with individual heterogeneity characteristic impedance causes a change in shape and duration of the probe signal rectangular. Practical value. Time domain reflectometer can be considered as one of the promising methods for diagnosing operational irregularities (ellipticity, eccentricity, water treeing) in power cables.G. V. BezprozvannychA. G. Kyessayev National Technical University "Kharkiv Polytechnic Institute"articleeccentricityellipticity of insulationwater treeingelectric field strengththe wave impedancethe probe pulseElectrical engineering. Electronics. Nuclear engineeringTK1-9971ENRUUKElectrical engineering & Electromechanics, Iss 6, Pp 54-59 (2016)
institution DOAJ
collection DOAJ
language EN
RU
UK
topic eccentricity
ellipticity of insulation
water treeing
electric field strength
the wave impedance
the probe pulse
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
spellingShingle eccentricity
ellipticity of insulation
water treeing
electric field strength
the wave impedance
the probe pulse
Electrical engineering. Electronics. Nuclear engineering
TK1-9971
G. V. Bezprozvannych
A. G. Kyessayev
THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN
description Introduction. Reliability of high voltage power cables in the process of long-term operation is largely due to the intensity of polymeric insulation aging. It is now established that the aging of polyethylene, which is the main material for the insulation of high voltage power cables, under the action of the electric field is determined primarily by the presence of structural heterogeneity arising both during cable production and during use. The cable is always there deviations from the ideal structure, which manifest in a deviation of diameters of conductors from nominal values; in the arrangement of the conductor and the insulation is not strictly coaxially and eccentrically; in elliptic (oval) core and insulation; change in relative dielectric constant and thickness of insulation on cable length force the formation of low molecular weight products (including water) in the flow at the manufacturing stage crosslinked polyethylene insulation and moisture during operation. Such defects are structural, technological and operational irregularities, which lead to a local change in the electric field. Purpose. Analysis of the influence of the eccentricity, elliptic and spherical inclusions in the electric field distribution in the power cable of a coaxial design with cross-linked polyethylene insulation, based on numerical simulation. Methodology. The bases of the numerical method of calculation of the electrical field strength are Fredholm integral equations of the first and second kind (method of secondary sources) for an axially symmetric field. Analysis of the influence of irregularities, including water treeing, the shape of the sounding signal is made using the method of discrete resistive circuit inductance and capacitance of substitution with the initial conditions. Solving systems of linear algebraic equations nodal analysis performed by the sweep method. Results. The presence of the eccentricity and ellipticity in the construction of cable has different effects on the distribution of the electrical field strength at the conductor and the insulation. The electrical field strength is increased by 50 % in the core and 17 % - on the surface of the insulation at 10 % eccentricity between conductor and insulation. Availability elliptic insulation leads to a redistribution of the electric field: field strength at the surface of the insulation is 2 times higher electric field strength on the surface of the conductor. Water treeing spherical shape filled with water with a dielectric constant of 6.9, lead to a local increase of electric field intensity is 5 - 10 times. Originality. Simulation results show that the presence of water treeing concentrated with individual heterogeneity characteristic impedance causes a change in shape and duration of the probe signal rectangular. Practical value. Time domain reflectometer can be considered as one of the promising methods for diagnosing operational irregularities (ellipticity, eccentricity, water treeing) in power cables.
format article
author G. V. Bezprozvannych
A. G. Kyessayev
author_facet G. V. Bezprozvannych
A. G. Kyessayev
author_sort G. V. Bezprozvannych
title THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN
title_short THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN
title_full THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN
title_fullStr THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN
title_full_unstemmed THE TECHNOLOGICAL AND EXPLOITATIVE FACTORS OF LOCAL INCREASE OF ELECTRIC FIELD STRENGTH IN THE POWER CABLE OF COAXIAL DESIGN
title_sort technological and exploitative factors of local increase of electric field strength in the power cable of coaxial design
publisher National Technical University "Kharkiv Polytechnic Institute"
publishDate 2016
url https://doaj.org/article/67e57997d5f64075b26f238ba2831bb4
work_keys_str_mv AT gvbezprozvannych thetechnologicalandexploitativefactorsoflocalincreaseofelectricfieldstrengthinthepowercableofcoaxialdesign
AT agkyessayev thetechnologicalandexploitativefactorsoflocalincreaseofelectricfieldstrengthinthepowercableofcoaxialdesign
AT gvbezprozvannych technologicalandexploitativefactorsoflocalincreaseofelectricfieldstrengthinthepowercableofcoaxialdesign
AT agkyessayev technologicalandexploitativefactorsoflocalincreaseofelectricfieldstrengthinthepowercableofcoaxialdesign
_version_ 1718387818579886080