Visual performance of the Tecnis one-piece lens ZCB00
Sherein S Wahba, Riad F Riad, Fathy F Morkos, Abdallah K Hassouna, Maged M RoshdyNational Eye Hospital and Ain Shams University, Cairo, EgyptSynopsis: The aspheric, one-piece design of the Tecnis® ZCB00 intraocular lens provided higher mesopic contrast sensitivity and relatively constant...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Dove Medical Press
2011
|
Materias: | |
Acceso en línea: | https://doaj.org/article/6ae91106ab974429a1d6cba59b7e0991 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:6ae91106ab974429a1d6cba59b7e0991 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:6ae91106ab974429a1d6cba59b7e09912021-12-02T02:32:19ZVisual performance of the Tecnis one-piece lens ZCB001177-54671177-5483https://doaj.org/article/6ae91106ab974429a1d6cba59b7e09912011-12-01T00:00:00Zhttp://www.dovepress.com/visual-performance-of-the-tecnis-one-piece-lens-zcb00-a8948https://doaj.org/toc/1177-5467https://doaj.org/toc/1177-5483Sherein S Wahba, Riad F Riad, Fathy F Morkos, Abdallah K Hassouna, Maged M RoshdyNational Eye Hospital and Ain Shams University, Cairo, EgyptSynopsis: The aspheric, one-piece design of the Tecnis® ZCB00 intraocular lens provided higher mesopic contrast sensitivity and relatively constant refraction at different pupil sizes compared to the Sensar® AR40e.Purpose: Comparing the impact on functional vision of the aspheric Tecnis® ZCB00 one-piece lens compared to the spherical Sensar® AR40e three-piece lens.Setting: National Eye Hospital, Cairo, Egypt.Methods: In this prospective study, we implanted 32 Tecnis ZCB00 (Abbott Medical Optics, Santa Ana, CA) and 30 Sensar AR40e (Pharamacia and Upjohn LLC, North Peapack, NJ) lenses. Twenty-three patients in the ZCB00 group and 13 patients in the AR40e group provided reliable, reproducible data, and were therefore included in the statistical analysis. After 8 weeks, we measured photopic contrast sensitivity (PCS) at 85 cd/m² and mesopic contrast sensitivity (MCS) at 5 cd/m². Uncorrected and best-corrected visual acuity were measured. Myopic shift was analyzed by comparing the manifest refraction spherical equivalent at 3 days and 8 weeks after surgery in the normal and dilated pupil.Results: The Tecnis ZCB00 group showed significantly better MCS than the Sensar AR40e group at a spatial frequency of six cycles per degree (cpd) (P = 0.037), but not at 3, 12, or 18 cpd (P = 0.299, P = 0.226, and P = 0.396, respectively). There were no significant differences between groups in corrected distance visual acuity (P = 0.175) or PCS at 3, 6, 12, or 18 cpd spatial frequencies (P = 0.440, P = 0.176, P = 0.365, and P = 0.251, respectively). The ZCB00 group showed less myopic shift in normal and dilated pupils between 3 days and 8 weeks after surgery compared to the AR40e group, but this difference was not significant.Conclusion: The Tecnis one-piece ZCB00 provided higher MCS at moderate spatial frequency than the three-piece Sensar AR40e, and was associated with relatively constant refraction at different pupil sizes.Keywords: Tecnis ZCB00, Sensar AR40e, contrast sensitivity, myopic shiftWahba SSRiad RFMorkos FFHassouna AKRoshdy MMDove Medical PressarticleOphthalmologyRE1-994ENClinical Ophthalmology, Vol 2011, Iss default, Pp 1803-1808 (2011) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Ophthalmology RE1-994 |
spellingShingle |
Ophthalmology RE1-994 Wahba SS Riad RF Morkos FF Hassouna AK Roshdy MM Visual performance of the Tecnis one-piece lens ZCB00 |
description |
Sherein S Wahba, Riad F Riad, Fathy F Morkos, Abdallah K Hassouna, Maged M RoshdyNational Eye Hospital and Ain Shams University, Cairo, EgyptSynopsis: The aspheric, one-piece design of the Tecnis® ZCB00 intraocular lens provided higher mesopic contrast sensitivity and relatively constant refraction at different pupil sizes compared to the Sensar® AR40e.Purpose: Comparing the impact on functional vision of the aspheric Tecnis® ZCB00 one-piece lens compared to the spherical Sensar® AR40e three-piece lens.Setting: National Eye Hospital, Cairo, Egypt.Methods: In this prospective study, we implanted 32 Tecnis ZCB00 (Abbott Medical Optics, Santa Ana, CA) and 30 Sensar AR40e (Pharamacia and Upjohn LLC, North Peapack, NJ) lenses. Twenty-three patients in the ZCB00 group and 13 patients in the AR40e group provided reliable, reproducible data, and were therefore included in the statistical analysis. After 8 weeks, we measured photopic contrast sensitivity (PCS) at 85 cd/m² and mesopic contrast sensitivity (MCS) at 5 cd/m². Uncorrected and best-corrected visual acuity were measured. Myopic shift was analyzed by comparing the manifest refraction spherical equivalent at 3 days and 8 weeks after surgery in the normal and dilated pupil.Results: The Tecnis ZCB00 group showed significantly better MCS than the Sensar AR40e group at a spatial frequency of six cycles per degree (cpd) (P = 0.037), but not at 3, 12, or 18 cpd (P = 0.299, P = 0.226, and P = 0.396, respectively). There were no significant differences between groups in corrected distance visual acuity (P = 0.175) or PCS at 3, 6, 12, or 18 cpd spatial frequencies (P = 0.440, P = 0.176, P = 0.365, and P = 0.251, respectively). The ZCB00 group showed less myopic shift in normal and dilated pupils between 3 days and 8 weeks after surgery compared to the AR40e group, but this difference was not significant.Conclusion: The Tecnis one-piece ZCB00 provided higher MCS at moderate spatial frequency than the three-piece Sensar AR40e, and was associated with relatively constant refraction at different pupil sizes.Keywords: Tecnis ZCB00, Sensar AR40e, contrast sensitivity, myopic shift |
format |
article |
author |
Wahba SS Riad RF Morkos FF Hassouna AK Roshdy MM |
author_facet |
Wahba SS Riad RF Morkos FF Hassouna AK Roshdy MM |
author_sort |
Wahba SS |
title |
Visual performance of the Tecnis one-piece lens ZCB00 |
title_short |
Visual performance of the Tecnis one-piece lens ZCB00 |
title_full |
Visual performance of the Tecnis one-piece lens ZCB00 |
title_fullStr |
Visual performance of the Tecnis one-piece lens ZCB00 |
title_full_unstemmed |
Visual performance of the Tecnis one-piece lens ZCB00 |
title_sort |
visual performance of the tecnis one-piece lens zcb00 |
publisher |
Dove Medical Press |
publishDate |
2011 |
url |
https://doaj.org/article/6ae91106ab974429a1d6cba59b7e0991 |
work_keys_str_mv |
AT wahbass visualperformanceofthetecnisonepiecelenszcb00 AT riadrf visualperformanceofthetecnisonepiecelenszcb00 AT morkosff visualperformanceofthetecnisonepiecelenszcb00 AT hassounaak visualperformanceofthetecnisonepiecelenszcb00 AT roshdymm visualperformanceofthetecnisonepiecelenszcb00 |
_version_ |
1718402413751173120 |