DIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM
Objective: To determine the diagnostic accuracy of in-house biochemical testing for identification of enterococcus species isolated from various clinical specimens against gold standard i.e., automated Vitek 2 system. This study also includes the antimicrobial susceptibility testing of enterococci a...
Guardado en:
Autores principales: | , , , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Army Medical College Rawalpindi
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/6bd2b198851748a8a4529c83c806d538 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:6bd2b198851748a8a4529c83c806d538 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:6bd2b198851748a8a4529c83c806d5382021-12-02T18:01:28ZDIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM0030-96482411-884210.51253/pafmj.v71i1.3095https://doaj.org/article/6bd2b198851748a8a4529c83c806d5382021-02-01T00:00:00Zhttps://pafmj.org/index.php/PAFMJ/article/view/3095https://doaj.org/toc/0030-9648https://doaj.org/toc/2411-8842Objective: To determine the diagnostic accuracy of in-house biochemical testing for identification of enterococcus species isolated from various clinical specimens against gold standard i.e., automated Vitek 2 system. This study also includes the antimicrobial susceptibility testing of enterococci against various antimicrobials. Study Design: Cross-sectional comparative study. Place and Duration of Study: Department of Microbiology, Armed Forces Institute of Pathology, Rawalpindi, from Apr 2017 to Mar 2018. Methodology: A total of 218 isolates from various clinical specimens suspected to be Enterococcus spp. were checked by in-house biochemical testing including bile esculin, 6.5% NaCl and 1% arabinose and results were compared with Vitek 2 compact system. The frequencies were determined by both systems and antimicrobial susceptibility testing was performed by disk diffusion as per clinical and laboratory standards institute guidelines. Results: Comparing the results of in-house testing with gold standard i.e., Vitek 2 system, the statistical data was calculated. Sensitivity turned out to be 100%, Specificity was found to be 68.75%. Positive and negative predictive values were 97.58% and 100% respectively. Accuracy turned out to be 97.71%. Conclusion: The in-house biochemical testing can be quite a useful method for identification of enterococci in resource-limited settings. However, it requires overight incubation and cannot identify other enterococcal species and non-enterococcal species. Vitek 2 is an automated system that is easy-to-handle, provides a rapid and reasonably accurate identification of enterococci alongwith accurate AST results. Enterococcal isolates from various clinical specimens in our setup showed least resistance to linezolid, followed by teicoplanin and vancomycin. Nitrofurantoin and.............Mariam SarwarSyed Adeel Hussain GardeziGohar ZamanAamer IkramWajid HussainMuhammad Tahir KhadimArmy Medical College Rawalpindiarticleenterococcus sppin-house biochemical testingvitek 2 systemMedicineRMedicine (General)R5-920ENPakistan Armed Forces Medical Journal, Vol 71, Iss 1, Pp 155-61 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
enterococcus spp in-house biochemical testing vitek 2 system Medicine R Medicine (General) R5-920 |
spellingShingle |
enterococcus spp in-house biochemical testing vitek 2 system Medicine R Medicine (General) R5-920 Mariam Sarwar Syed Adeel Hussain Gardezi Gohar Zaman Aamer Ikram Wajid Hussain Muhammad Tahir Khadim DIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM |
description |
Objective: To determine the diagnostic accuracy of in-house biochemical testing for identification of enterococcus species isolated from various clinical specimens against gold standard i.e., automated Vitek 2 system. This study also includes the antimicrobial susceptibility testing of enterococci against various antimicrobials.
Study Design: Cross-sectional comparative study.
Place and Duration of Study: Department of Microbiology, Armed Forces Institute of Pathology, Rawalpindi,
from Apr 2017 to Mar 2018.
Methodology: A total of 218 isolates from various clinical specimens suspected to be Enterococcus spp. were
checked by in-house biochemical testing including bile esculin, 6.5% NaCl and 1% arabinose and results were
compared with Vitek 2 compact system. The frequencies were determined by both systems and antimicrobial susceptibility testing was performed by disk diffusion as per clinical and laboratory standards institute guidelines.
Results: Comparing the results of in-house testing with gold standard i.e., Vitek 2 system, the statistical data was calculated. Sensitivity turned out to be 100%, Specificity was found to be 68.75%. Positive and negative predictive values were 97.58% and 100% respectively. Accuracy turned out to be 97.71%.
Conclusion: The in-house biochemical testing can be quite a useful method for identification of enterococci in
resource-limited settings. However, it requires overight incubation and cannot identify other enterococcal species and non-enterococcal species. Vitek 2 is an automated system that is easy-to-handle, provides a rapid and reasonably accurate identification of enterococci alongwith accurate AST results. Enterococcal isolates from various clinical specimens in our setup showed least resistance to linezolid, followed by teicoplanin and vancomycin. Nitrofurantoin and............. |
format |
article |
author |
Mariam Sarwar Syed Adeel Hussain Gardezi Gohar Zaman Aamer Ikram Wajid Hussain Muhammad Tahir Khadim |
author_facet |
Mariam Sarwar Syed Adeel Hussain Gardezi Gohar Zaman Aamer Ikram Wajid Hussain Muhammad Tahir Khadim |
author_sort |
Mariam Sarwar |
title |
DIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM |
title_short |
DIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM |
title_full |
DIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM |
title_fullStr |
DIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM |
title_full_unstemmed |
DIAGNOSTIC ACCURACY OF IN-HOUSE BIOCHEMICAL TESTING FOR IDENTIFICATION OF ENTEROCOCCUS SPECIES ISOLATED FROM VARIOUS CLINICAL SPECIMENSAGAINST VITEK 2 SYSTEM |
title_sort |
diagnostic accuracy of in-house biochemical testing for identification of enterococcus species isolated from various clinical specimensagainst vitek 2 system |
publisher |
Army Medical College Rawalpindi |
publishDate |
2021 |
url |
https://doaj.org/article/6bd2b198851748a8a4529c83c806d538 |
work_keys_str_mv |
AT mariamsarwar diagnosticaccuracyofinhousebiochemicaltestingforidentificationofenterococcusspeciesisolatedfromvariousclinicalspecimensagainstvitek2system AT syedadeelhussaingardezi diagnosticaccuracyofinhousebiochemicaltestingforidentificationofenterococcusspeciesisolatedfromvariousclinicalspecimensagainstvitek2system AT goharzaman diagnosticaccuracyofinhousebiochemicaltestingforidentificationofenterococcusspeciesisolatedfromvariousclinicalspecimensagainstvitek2system AT aamerikram diagnosticaccuracyofinhousebiochemicaltestingforidentificationofenterococcusspeciesisolatedfromvariousclinicalspecimensagainstvitek2system AT wajidhussain diagnosticaccuracyofinhousebiochemicaltestingforidentificationofenterococcusspeciesisolatedfromvariousclinicalspecimensagainstvitek2system AT muhammadtahirkhadim diagnosticaccuracyofinhousebiochemicaltestingforidentificationofenterococcusspeciesisolatedfromvariousclinicalspecimensagainstvitek2system |
_version_ |
1718378994707988480 |