Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique

(1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient frac...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Frank Layher, Georg Matziolis, Leos N. Kayhan, Matthias Bungartz, Olaf Brinkmann
Formato: article
Lenguaje:EN
Publicado: MDPI AG 2021
Materias:
Q
Acceso en línea:https://doaj.org/article/6c6a1d3eefbc4acf8a79d34a79e852a4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:6c6a1d3eefbc4acf8a79d34a79e852a4
record_format dspace
spelling oai:doaj.org-article:6c6a1d3eefbc4acf8a79d34a79e852a42021-11-25T18:11:36ZMinimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique10.3390/life111112542075-1729https://doaj.org/article/6c6a1d3eefbc4acf8a79d34a79e852a42021-11-01T00:00:00Zhttps://www.mdpi.com/2075-1729/11/11/1254https://doaj.org/toc/2075-1729(1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically. (2) Methods: The unilaterally applied spinal internal fixator (IF) was subjected to load and deformation analysis on artificial femurs with 32-A3 fracture according to AO classification. Distance of screws to fracture and rod to cortical bone were analysed as parameters influenced surgically as stiffness and deformation of the treated fracture. In addition, the stability of another construct with a second screw/rod system was determined. The axial load in stance phase during walking was simulated. The results were compared against an established fixed-angle plate osteosynthesis (IP). (3) Results: There were no implant failures in the form of fractures, avulsions or deformations. All unilateral IF combinations were inferior to IP in terms of stability and stiffness. The bilateral construct with two screw/rod systems achieved biomechanical properties comparable to IP. 4) Conclusion: Biomechanically, a biplanar screw/rod system is suitable for definitive fracture stabilisation of the femur, despite a damage control approach.Frank LayherGeorg MatziolisLeos N. KayhanMatthias BungartzOlaf BrinkmannMDPI AGarticlefemur fracturebiomechanical studysawboneinternal fixatordisruptive techniqueScienceQENLife, Vol 11, Iss 1254, p 1254 (2021)
institution DOAJ
collection DOAJ
language EN
topic femur fracture
biomechanical study
sawbone
internal fixator
disruptive technique
Science
Q
spellingShingle femur fracture
biomechanical study
sawbone
internal fixator
disruptive technique
Science
Q
Frank Layher
Georg Matziolis
Leos N. Kayhan
Matthias Bungartz
Olaf Brinkmann
Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
description (1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically. (2) Methods: The unilaterally applied spinal internal fixator (IF) was subjected to load and deformation analysis on artificial femurs with 32-A3 fracture according to AO classification. Distance of screws to fracture and rod to cortical bone were analysed as parameters influenced surgically as stiffness and deformation of the treated fracture. In addition, the stability of another construct with a second screw/rod system was determined. The axial load in stance phase during walking was simulated. The results were compared against an established fixed-angle plate osteosynthesis (IP). (3) Results: There were no implant failures in the form of fractures, avulsions or deformations. All unilateral IF combinations were inferior to IP in terms of stability and stiffness. The bilateral construct with two screw/rod systems achieved biomechanical properties comparable to IP. 4) Conclusion: Biomechanically, a biplanar screw/rod system is suitable for definitive fracture stabilisation of the femur, despite a damage control approach.
format article
author Frank Layher
Georg Matziolis
Leos N. Kayhan
Matthias Bungartz
Olaf Brinkmann
author_facet Frank Layher
Georg Matziolis
Leos N. Kayhan
Matthias Bungartz
Olaf Brinkmann
author_sort Frank Layher
title Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
title_short Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
title_full Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
title_fullStr Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
title_full_unstemmed Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
title_sort minimally invasive internal fixation of femoral shaft fractures—a biomechanical study with a disruptive technique
publisher MDPI AG
publishDate 2021
url https://doaj.org/article/6c6a1d3eefbc4acf8a79d34a79e852a4
work_keys_str_mv AT franklayher minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique
AT georgmatziolis minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique
AT leosnkayhan minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique
AT matthiasbungartz minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique
AT olafbrinkmann minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique
_version_ 1718411501648216064