Regulated upon activation, normal T cells expressed and secreted (CCL5) in platelet concentrate: Role of mode of preparation and duration of storage
BACKGROUND AND OBJECTIVES: Platelet concentrates (PCs) can be prepared in several different ways, and they can be stored over few days before the use. Regulated on activation, normal T cells expressed and secreted (RANTES) levels in these concentrates may vary depending on the type of preparation an...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Wolters Kluwer Medknow Publications
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/6d60bfd91ec94807a010eeaa8b6994dc |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
Sumario: | BACKGROUND AND OBJECTIVES: Platelet concentrates (PCs) can be prepared in several different ways, and they can be stored over few days before the use. Regulated on activation, normal T cells expressed and secreted (RANTES) levels in these concentrates may vary depending on the type of preparation and duration of storage of this component. We measured RANTES levels in platelet supernatants in different preparations and with different storage duration.MATERIALS AND METHODS: Fifteen PCs were prepared by platelet-rich plasma (PRP) and buffy coat (BC) method each. Forty-two single donor platelets (SDPs) were prepared using cell separators Cobe Spectra, Trima Accel, and Amicus. Filtered PCs were prepared using labside and bedside filters. The supernatants were collected after 1, 18, 65, and 112 h of preparation. SDP samples were taken on the 0 day, 3rd day, and 5th day. In filtered PC, pre- and post-filtration samples were taken, and aliquots were frozen at − 56°C for the measurement of RANTES.RESULTS: RANTES at 1 h was 1210 ± 560 pg/ml in PRP-PC, 1384 ± 463 pg/ml in BC-PC. At 112 h, 1617 ± 451 pg/ml and 1949 ± 134 pg/ml, respectively. In SDP, 0-day level was 1850 ± 278 pg/ml and >2000 pg/ml on 5th day. In prestorage, filtered PC RANTES was 1035 ± 496 pg/ml, and in the poststorage sample, it was 310 ± 508 pg/ml. With bedside filters, presample showed 1243 ± 832 pg/ml and postsample showed 556 ± 748 pg/ml.CONCLUSION: The concentration of RANTES increased continuously from 1 h to 5 days of storage in all PCs. After 65 h, BC-PC showed higher levels of RANTES compared to PRP-PC. Filtered PRP-PCs appear to be the best in terms of low RANTES to prevent allergic reactions and cultures negative. |
---|