In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating

Yonggang Dang,1 Li Zhang,1 Wen Song,1 Bei Chang,1 Tianxiao Han,1 Yumei Zhang,1 Lingzhou Zhao2 1Department of Prosthetic Dentistry, 2Department of Periodontology, School of Stomatology, State Key Laboratory of Military Stomatology, The Fourth Military Medical University, Xi’an, People&...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Dang Y, Zhang L, Song W, Chang B, Han T, Zhang Y, Zhao L
Formato: article
Lenguaje:EN
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://doaj.org/article/6d7b5ccc98a9478a990d3fe4849af56c
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:6d7b5ccc98a9478a990d3fe4849af56c
record_format dspace
spelling oai:doaj.org-article:6d7b5ccc98a9478a990d3fe4849af56c2021-12-02T01:34:50ZIn vivo osseointegration of Ti implants with a strontium-containing nanotubular coating1178-2013https://doaj.org/article/6d7b5ccc98a9478a990d3fe4849af56c2016-03-01T00:00:00Zhttps://www.dovepress.com/in-vivo-osseointegration-of-ti-implants-with-a-strontium-containing-na-peer-reviewed-article-IJNhttps://doaj.org/toc/1178-2013Yonggang Dang,1 Li Zhang,1 Wen Song,1 Bei Chang,1 Tianxiao Han,1 Yumei Zhang,1 Lingzhou Zhao2 1Department of Prosthetic Dentistry, 2Department of Periodontology, School of Stomatology, State Key Laboratory of Military Stomatology, The Fourth Military Medical University, Xi’an, People’s Republic of China Abstract: Novel biomedical titanium (Ti) implants with high osteogenic ability for fast and good osseointegration under normal as well as osteoporotic conditions are urgently needed. Expanding on our previous in vitro results, we hypothesized that nanotubular, strontium-loaded (NT-Sr) structures on Ti implants would have favorable osteogenic effects and evaluated the in vivo osseointegration of these implants in rats. The structures with nanotubes of different diameters were fabricated by electrochemical anodization at 10 and 40 V, and the amounts of Sr loaded were adjusted by using two hydrothermal treatment times of 1 and 3 hours. Qualitative microcomputed tomography in two and three dimensions showed that the NT-Sr formed with an anodization voltage of 10 V and hydrothermal treatment time of 3 hours best supported bone growth in vivo. Histomorphometric examination of osseointegration also showed that more newly formed bone was found at its surface. The bone–implant contact percentage was highest (92.48%±0.76%) at 12 weeks. In conclusion, the NT-Sr formed with an anodization voltage of 10 V and hydrothermal treatment time of 3 hours showed excellent osteogenic properties, making it an attractive option for Ti surface modification with considerable clinical potential. Keywords: titania nanotubes, strontium, osseointegration, in vivoDang YZhang LSong WChang BHan TZhang YZhao LDove Medical PressarticleTitania nanotubesStrontiumOsseointegrationIn vivoMedicine (General)R5-920ENInternational Journal of Nanomedicine, Vol 2016, Iss default, Pp 1003-1011 (2016)
institution DOAJ
collection DOAJ
language EN
topic Titania nanotubes
Strontium
Osseointegration
In vivo
Medicine (General)
R5-920
spellingShingle Titania nanotubes
Strontium
Osseointegration
In vivo
Medicine (General)
R5-920
Dang Y
Zhang L
Song W
Chang B
Han T
Zhang Y
Zhao L
In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating
description Yonggang Dang,1 Li Zhang,1 Wen Song,1 Bei Chang,1 Tianxiao Han,1 Yumei Zhang,1 Lingzhou Zhao2 1Department of Prosthetic Dentistry, 2Department of Periodontology, School of Stomatology, State Key Laboratory of Military Stomatology, The Fourth Military Medical University, Xi’an, People’s Republic of China Abstract: Novel biomedical titanium (Ti) implants with high osteogenic ability for fast and good osseointegration under normal as well as osteoporotic conditions are urgently needed. Expanding on our previous in vitro results, we hypothesized that nanotubular, strontium-loaded (NT-Sr) structures on Ti implants would have favorable osteogenic effects and evaluated the in vivo osseointegration of these implants in rats. The structures with nanotubes of different diameters were fabricated by electrochemical anodization at 10 and 40 V, and the amounts of Sr loaded were adjusted by using two hydrothermal treatment times of 1 and 3 hours. Qualitative microcomputed tomography in two and three dimensions showed that the NT-Sr formed with an anodization voltage of 10 V and hydrothermal treatment time of 3 hours best supported bone growth in vivo. Histomorphometric examination of osseointegration also showed that more newly formed bone was found at its surface. The bone–implant contact percentage was highest (92.48%±0.76%) at 12 weeks. In conclusion, the NT-Sr formed with an anodization voltage of 10 V and hydrothermal treatment time of 3 hours showed excellent osteogenic properties, making it an attractive option for Ti surface modification with considerable clinical potential. Keywords: titania nanotubes, strontium, osseointegration, in vivo
format article
author Dang Y
Zhang L
Song W
Chang B
Han T
Zhang Y
Zhao L
author_facet Dang Y
Zhang L
Song W
Chang B
Han T
Zhang Y
Zhao L
author_sort Dang Y
title In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating
title_short In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating
title_full In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating
title_fullStr In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating
title_full_unstemmed In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating
title_sort in vivo osseointegration of ti implants with a strontium-containing nanotubular coating
publisher Dove Medical Press
publishDate 2016
url https://doaj.org/article/6d7b5ccc98a9478a990d3fe4849af56c
work_keys_str_mv AT dangy invivoosseointegrationoftiimplantswithastrontiumcontainingnanotubularcoating
AT zhangl invivoosseointegrationoftiimplantswithastrontiumcontainingnanotubularcoating
AT songw invivoosseointegrationoftiimplantswithastrontiumcontainingnanotubularcoating
AT changb invivoosseointegrationoftiimplantswithastrontiumcontainingnanotubularcoating
AT hant invivoosseointegrationoftiimplantswithastrontiumcontainingnanotubularcoating
AT zhangy invivoosseointegrationoftiimplantswithastrontiumcontainingnanotubularcoating
AT zhaol invivoosseointegrationoftiimplantswithastrontiumcontainingnanotubularcoating
_version_ 1718402964039663616