Assessment of energy performance gap of an office building
The high share of global energy costs to create an indoor climate has been of increasing interest to the global community for several decades and is increasingly the focus of policy. This paper analyses the energy performance gap between actual energy consumption and energy demand obtained during th...
Guardado en:
Autores principales: | , |
---|---|
Formato: | article |
Lenguaje: | EN LT |
Publicado: |
Vilnius Gediminas Technical University
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/6da11ae2a9e54164ba2bc24e38848043 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:6da11ae2a9e54164ba2bc24e38848043 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:6da11ae2a9e54164ba2bc24e388480432021-11-23T14:40:53ZAssessment of energy performance gap of an office building2029-23412029-225210.3846/mla.2021.15292https://doaj.org/article/6da11ae2a9e54164ba2bc24e388480432021-10-01T00:00:00Zhttps://journals.vgtu.lt/index.php/MLA/article/view/15292https://doaj.org/toc/2029-2341https://doaj.org/toc/2029-2252The high share of global energy costs to create an indoor climate has been of increasing interest to the global community for several decades and is increasingly the focus of policy. This paper analyses the energy performance gap between actual energy consumption and energy demand obtained during the dynamic energy simulation and building certification. To identify the energy performance gap, an existing office of energy efficiency class B was selected as a case study. The simulation program IDA Indoor Climate and Energy was used to create a dynamic energy model, based on the designed documentation and the actual indoor climate parameters recorded by the building management system. The results of the case study showed that the accuracy and reliability of the results presented by the dynamic energy model of the building directly depend on the assumptions. The correct values of the internal heat gains, indoor climate parameters, human behavior, air quality levels at different times of the day and season, HVAC system operation parameters and operation modes, specific fan powers of ventilation systems, the seasonal energy efficiency of cooling equipment and characteristics of sun protection measures have to be selected. Article in Lithuanian. Administracinio pastato energijos vartojimo efektyvumo spragos vertinimas Santrauka Patalpų mikroklimatui sukurti tenkanti didelė globalių energijos sąnaudų dalis jau keletą dešimtmečių vis labiau domina pasaulinę bendruomenę, vis dažniau ši problema atsiduria ir politikos dėmesio centre. Šiame straipsnyje nagrinėjama energijos efektyvumo spraga tarp faktinių energijos sąnaudų ir energijos poreikių, gautų dinaminio energinio modeliavimo bei sertifikavimo metu. Siekiant nustatyti energijos efektyvumo spragą ir ją lemiančias priežastis, tyrimui pasirinktas administracinės paskirties pastatas, kuris atitinka B energinio naudingumo klasę. Kompiuterinė programa „IDA Indoor Climate and Energy“ panaudota dinaminiam energiniam modeliui sukurti pagal projektinę dokumentaciją ir pastato valdymo sistemoje fiksuojamus faktinius patalpų mikroklimato parametrus. Tyrimo rezultatai atskleidė, kad pastato dinaminio energinio modelio pateiktų rezultatų tikslumas ir patikimumas tiesiogiai priklauso nuo prielaidų, padarytų dėl vidinių šilumos pritėkių dydžių, mikroklimato parametrų kitimo ribų, žmonių elgsenos ypatumų, oro kokybės lygių skirtingu paros ir sezono laikotarpiais, ŠVOK sistemų veikimo parametrų ir režimų, vėdinimo sistemų savitųjų ventiliatorių galių, vėsinimo įrenginių sezoninio energinio efektyvumo ir įstiklintos fasado dalies apsaugos nuo saulės priemonių charakteristikų nustatymo. Reikšminiai žodžiai: administracinis pastatas, dinaminis energinis modeliavimas, IDA-ICE, energijos vartojimo efektyvumo spraga, faktinės energijos sąnaudos, sertifikavimas.Rasa Džiugaitė-TumėnienėDomas MadeikisVilnius Gediminas Technical Universityarticleoffice buildingdynamic energy simulationida-iceenergy performance gapactual energy consumptioncertificateTechnologyTScienceQENLTMokslas: Lietuvos Ateitis, Vol 13 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN LT |
topic |
office building dynamic energy simulation ida-ice energy performance gap actual energy consumption certificate Technology T Science Q |
spellingShingle |
office building dynamic energy simulation ida-ice energy performance gap actual energy consumption certificate Technology T Science Q Rasa Džiugaitė-Tumėnienė Domas Madeikis Assessment of energy performance gap of an office building |
description |
The high share of global energy costs to create an indoor climate has been of increasing interest to the global community for several decades and is increasingly the focus of policy. This paper analyses the energy performance gap between actual energy consumption and energy demand obtained during the dynamic energy simulation and building certification. To identify the energy performance gap, an existing office of energy efficiency class B was selected as a case study. The simulation program IDA Indoor Climate and Energy was used to create a dynamic energy model, based on the designed documentation and the actual indoor climate parameters recorded by the building management system. The results of the case study showed that the accuracy and reliability of the results presented by the dynamic energy model of the building directly depend on the assumptions. The correct values of the internal heat gains, indoor climate parameters, human behavior, air quality levels at different times of the day and season, HVAC system operation parameters and operation modes, specific fan powers of ventilation systems, the seasonal energy efficiency of cooling equipment and characteristics of sun protection measures have to be selected.
Article in Lithuanian.
Administracinio pastato energijos vartojimo efektyvumo spragos vertinimas
Santrauka
Patalpų mikroklimatui sukurti tenkanti didelė globalių energijos sąnaudų dalis jau keletą dešimtmečių vis labiau domina pasaulinę bendruomenę, vis dažniau ši problema atsiduria ir politikos dėmesio centre. Šiame straipsnyje nagrinėjama energijos efektyvumo spraga tarp faktinių energijos sąnaudų ir energijos poreikių, gautų dinaminio energinio modeliavimo bei sertifikavimo metu. Siekiant nustatyti energijos efektyvumo spragą ir ją lemiančias priežastis, tyrimui pasirinktas administracinės paskirties pastatas, kuris atitinka B energinio naudingumo klasę. Kompiuterinė programa „IDA Indoor Climate and Energy“ panaudota dinaminiam energiniam modeliui sukurti pagal projektinę dokumentaciją ir pastato valdymo sistemoje fiksuojamus faktinius patalpų mikroklimato parametrus. Tyrimo rezultatai atskleidė, kad pastato dinaminio energinio modelio pateiktų rezultatų tikslumas ir patikimumas tiesiogiai priklauso nuo prielaidų, padarytų dėl vidinių šilumos pritėkių dydžių, mikroklimato parametrų kitimo ribų, žmonių elgsenos ypatumų, oro kokybės lygių skirtingu paros ir sezono laikotarpiais, ŠVOK sistemų veikimo parametrų ir režimų, vėdinimo sistemų savitųjų ventiliatorių galių, vėsinimo įrenginių sezoninio energinio efektyvumo ir įstiklintos fasado dalies apsaugos nuo saulės priemonių charakteristikų nustatymo.
Reikšminiai žodžiai: administracinis pastatas, dinaminis energinis modeliavimas, IDA-ICE, energijos vartojimo efektyvumo spraga, faktinės energijos sąnaudos, sertifikavimas. |
format |
article |
author |
Rasa Džiugaitė-Tumėnienė Domas Madeikis |
author_facet |
Rasa Džiugaitė-Tumėnienė Domas Madeikis |
author_sort |
Rasa Džiugaitė-Tumėnienė |
title |
Assessment of energy performance gap of an office building |
title_short |
Assessment of energy performance gap of an office building |
title_full |
Assessment of energy performance gap of an office building |
title_fullStr |
Assessment of energy performance gap of an office building |
title_full_unstemmed |
Assessment of energy performance gap of an office building |
title_sort |
assessment of energy performance gap of an office building |
publisher |
Vilnius Gediminas Technical University |
publishDate |
2021 |
url |
https://doaj.org/article/6da11ae2a9e54164ba2bc24e38848043 |
work_keys_str_mv |
AT rasadziugaitetumeniene assessmentofenergyperformancegapofanofficebuilding AT domasmadeikis assessmentofenergyperformancegapofanofficebuilding |
_version_ |
1718416706985000960 |