Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India
In-stent restenosis and stent thrombosis are the major concerns while choosing a coronary stent. This single-centre, retrospective study evaluated the one and three-year clinical outcomes following implantation of Yukon Choice Flex (YCF) sirolimus-eluting stent. A total of 168 consecutive patients w...
Guardado en:
Autores principales: | , , , |
---|---|
Formato: | article |
Lenguaje: | EN |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://doaj.org/article/6ef57859ad334ee9a1a44f339a886134 |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
id |
oai:doaj.org-article:6ef57859ad334ee9a1a44f339a886134 |
---|---|
record_format |
dspace |
spelling |
oai:doaj.org-article:6ef57859ad334ee9a1a44f339a8861342021-12-02T04:57:59ZLong term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India0019-483210.1016/j.ihj.2021.09.006https://doaj.org/article/6ef57859ad334ee9a1a44f339a8861342021-11-01T00:00:00Zhttp://www.sciencedirect.com/science/article/pii/S0019483221001930https://doaj.org/toc/0019-4832In-stent restenosis and stent thrombosis are the major concerns while choosing a coronary stent. This single-centre, retrospective study evaluated the one and three-year clinical outcomes following implantation of Yukon Choice Flex (YCF) sirolimus-eluting stent. A total of 168 consecutive patients with 217 lesions underwent stenting with YCF stent. The presentation was with acute coronary syndrome in 158 (94%) patients. At 3 years, 9 (5.3%) patients died due to cardiac cause. Myocardial infarction, and definite stent thrombosis occurred in 10 (6%) and 4 (2.4%) patients respectively. Redo stenting and coronary artery bypass surgery was performed in 3 (1.8%) and 1 (0.6%) patient respectively. The use of YCF sirolimus eluting stent was associated with a favourable safety and efficacy profile at one and three-years of follow-up in a high-risk population.Basant KumarSourabh AgstamJyothi VijayAkash BattaElsevierarticleDrug-eluting stentYukon choice flexStent thrombosisIn-stent restenosisSurgeryRD1-811Diseases of the circulatory (Cardiovascular) systemRC666-701ENIndian Heart Journal, Vol 73, Iss 6, Pp 733-736 (2021) |
institution |
DOAJ |
collection |
DOAJ |
language |
EN |
topic |
Drug-eluting stent Yukon choice flex Stent thrombosis In-stent restenosis Surgery RD1-811 Diseases of the circulatory (Cardiovascular) system RC666-701 |
spellingShingle |
Drug-eluting stent Yukon choice flex Stent thrombosis In-stent restenosis Surgery RD1-811 Diseases of the circulatory (Cardiovascular) system RC666-701 Basant Kumar Sourabh Agstam Jyothi Vijay Akash Batta Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India |
description |
In-stent restenosis and stent thrombosis are the major concerns while choosing a coronary stent. This single-centre, retrospective study evaluated the one and three-year clinical outcomes following implantation of Yukon Choice Flex (YCF) sirolimus-eluting stent. A total of 168 consecutive patients with 217 lesions underwent stenting with YCF stent. The presentation was with acute coronary syndrome in 158 (94%) patients. At 3 years, 9 (5.3%) patients died due to cardiac cause. Myocardial infarction, and definite stent thrombosis occurred in 10 (6%) and 4 (2.4%) patients respectively. Redo stenting and coronary artery bypass surgery was performed in 3 (1.8%) and 1 (0.6%) patient respectively. The use of YCF sirolimus eluting stent was associated with a favourable safety and efficacy profile at one and three-years of follow-up in a high-risk population. |
format |
article |
author |
Basant Kumar Sourabh Agstam Jyothi Vijay Akash Batta |
author_facet |
Basant Kumar Sourabh Agstam Jyothi Vijay Akash Batta |
author_sort |
Basant Kumar |
title |
Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India |
title_short |
Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India |
title_full |
Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India |
title_fullStr |
Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India |
title_full_unstemmed |
Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India |
title_sort |
long term safety and efficacy of the yukon choice flex sirolimus-eluting coronary stent-a real-world data from india |
publisher |
Elsevier |
publishDate |
2021 |
url |
https://doaj.org/article/6ef57859ad334ee9a1a44f339a886134 |
work_keys_str_mv |
AT basantkumar longtermsafetyandefficacyoftheyukonchoiceflexsirolimuselutingcoronarystentarealworlddatafromindia AT sourabhagstam longtermsafetyandefficacyoftheyukonchoiceflexsirolimuselutingcoronarystentarealworlddatafromindia AT jyothivijay longtermsafetyandefficacyoftheyukonchoiceflexsirolimuselutingcoronarystentarealworlddatafromindia AT akashbatta longtermsafetyandefficacyoftheyukonchoiceflexsirolimuselutingcoronarystentarealworlddatafromindia |
_version_ |
1718400958522720256 |