A microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions

Abstract The isolation of sperm cells from background cell populations and debris is an essential step in all assisted reproductive technologies. Conventional techniques for sperm recovery from testicular sperm extractions stagnate at the sample processing stage, where it can take several hours to i...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Steven A. Vasilescu, Shayan Khorsandi, Lin Ding, Sajad Razavi Bazaz, Reza Nosrati, Debra Gook, Majid Ebrahimi Warkiani
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2021
Materias:
R
Q
Acceso en línea:https://doaj.org/article/6f60f55096354e7c8d910d0469a21549
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:6f60f55096354e7c8d910d0469a21549
record_format dspace
spelling oai:doaj.org-article:6f60f55096354e7c8d910d0469a215492021-12-02T18:03:46ZA microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions10.1038/s41598-021-87046-92045-2322https://doaj.org/article/6f60f55096354e7c8d910d0469a215492021-04-01T00:00:00Zhttps://doi.org/10.1038/s41598-021-87046-9https://doaj.org/toc/2045-2322Abstract The isolation of sperm cells from background cell populations and debris is an essential step in all assisted reproductive technologies. Conventional techniques for sperm recovery from testicular sperm extractions stagnate at the sample processing stage, where it can take several hours to identify viable sperm from a background of collateral cells such as white bloods cells (WBCs), red blood cells (RBCs), epithelial cells (ECs) and in some cases cancer cells. Manual identification of sperm from contaminating cells and debris is a tedious and time-consuming operation that can be suitably addressed through inertial microfluidics. Microfluidics has proven an effective technology for high-quality sperm selection based on motility. However, motility-based selection methods cannot cater for viable, non-motile sperm often present in testicular or epididymal sperm extractions and aspirations. This study demonstrates the use of a 3D printed inertial microfluidic device for the separation of sperm cells from a mixed suspension of WBCs, RBCs, ECs, and leukemic cancer cells. This technology presents a 36-fold time improvement for the recovery of sperm cells (> 96%) by separating sperm, RBCS, WBCs, ECs and cancer cells into tight bands in less than 5 min. Furthermore, microfluidic processing of sperm has no impact on sperm parameters; vitality, motility, morphology, or DNA fragmentation of sperm. Applying inertial microfluidics for non-motile sperm recovery can greatly improve the current processing procedure of testicular sperm extractions, simplifying the fertility outcomes for severe forms of male infertility that warrant the surgery.Steven A. VasilescuShayan KhorsandiLin DingSajad Razavi BazazReza NosratiDebra GookMajid Ebrahimi WarkianiNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 11, Iss 1, Pp 1-11 (2021)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
Steven A. Vasilescu
Shayan Khorsandi
Lin Ding
Sajad Razavi Bazaz
Reza Nosrati
Debra Gook
Majid Ebrahimi Warkiani
A microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions
description Abstract The isolation of sperm cells from background cell populations and debris is an essential step in all assisted reproductive technologies. Conventional techniques for sperm recovery from testicular sperm extractions stagnate at the sample processing stage, where it can take several hours to identify viable sperm from a background of collateral cells such as white bloods cells (WBCs), red blood cells (RBCs), epithelial cells (ECs) and in some cases cancer cells. Manual identification of sperm from contaminating cells and debris is a tedious and time-consuming operation that can be suitably addressed through inertial microfluidics. Microfluidics has proven an effective technology for high-quality sperm selection based on motility. However, motility-based selection methods cannot cater for viable, non-motile sperm often present in testicular or epididymal sperm extractions and aspirations. This study demonstrates the use of a 3D printed inertial microfluidic device for the separation of sperm cells from a mixed suspension of WBCs, RBCs, ECs, and leukemic cancer cells. This technology presents a 36-fold time improvement for the recovery of sperm cells (> 96%) by separating sperm, RBCS, WBCs, ECs and cancer cells into tight bands in less than 5 min. Furthermore, microfluidic processing of sperm has no impact on sperm parameters; vitality, motility, morphology, or DNA fragmentation of sperm. Applying inertial microfluidics for non-motile sperm recovery can greatly improve the current processing procedure of testicular sperm extractions, simplifying the fertility outcomes for severe forms of male infertility that warrant the surgery.
format article
author Steven A. Vasilescu
Shayan Khorsandi
Lin Ding
Sajad Razavi Bazaz
Reza Nosrati
Debra Gook
Majid Ebrahimi Warkiani
author_facet Steven A. Vasilescu
Shayan Khorsandi
Lin Ding
Sajad Razavi Bazaz
Reza Nosrati
Debra Gook
Majid Ebrahimi Warkiani
author_sort Steven A. Vasilescu
title A microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions
title_short A microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions
title_full A microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions
title_fullStr A microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions
title_full_unstemmed A microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions
title_sort microfluidic approach to rapid sperm recovery from heterogeneous cell suspensions
publisher Nature Portfolio
publishDate 2021
url https://doaj.org/article/6f60f55096354e7c8d910d0469a21549
work_keys_str_mv AT stevenavasilescu amicrofluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT shayankhorsandi amicrofluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT linding amicrofluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT sajadrazavibazaz amicrofluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT rezanosrati amicrofluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT debragook amicrofluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT majidebrahimiwarkiani amicrofluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT stevenavasilescu microfluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT shayankhorsandi microfluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT linding microfluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT sajadrazavibazaz microfluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT rezanosrati microfluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT debragook microfluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
AT majidebrahimiwarkiani microfluidicapproachtorapidspermrecoveryfromheterogeneouscellsuspensions
_version_ 1718378691511189504