Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration

Abstract Environmentally friendly and low-cost technologies to recover low-grade heat source into usable energy can contribute to ease the energy shortage. Thermoacoustic technology is expected as one promising approach in this ascendant field. In this work, the multi-stage looped thermoacoustic pri...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: T. Jin, R. Yang, Y. Wang, Y. Feng, K. Tang
Formato: article
Lenguaje:EN
Publicado: Nature Portfolio 2017
Materias:
R
Q
Acceso en línea:https://doaj.org/article/6f78aa377230405cb6cf06cf8197ddf4
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
id oai:doaj.org-article:6f78aa377230405cb6cf06cf8197ddf4
record_format dspace
spelling oai:doaj.org-article:6f78aa377230405cb6cf06cf8197ddf42021-12-02T16:06:36ZLow temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration10.1038/s41598-017-08124-52045-2322https://doaj.org/article/6f78aa377230405cb6cf06cf8197ddf42017-08-01T00:00:00Zhttps://doi.org/10.1038/s41598-017-08124-5https://doaj.org/toc/2045-2322Abstract Environmentally friendly and low-cost technologies to recover low-grade heat source into usable energy can contribute to ease the energy shortage. Thermoacoustic technology is expected as one promising approach in this ascendant field. In this work, the multi-stage looped thermoacoustic prime movers with asymmetric configuration, which can provide travelling-wave resonator and appropriate acoustic field for efficient regenerator, have been proposed and experimentally studied. The presented looped thermoacoustic prime movers can start to oscillate with quite low temperature difference along the regenerator. The lowest onset temperature difference obtained in the experiments is only 17 °C (the corresponding heating temperature is 29 °C), which can be achieved in both three-stage and four-stage looped thermoacoustic prime movers, with CO2 of 1 MPa or 1.5 MPa as the working fluid. An electric generator driven by a three-stage looped thermoacoustic prime mover with low heating temperature was tested to achieve the acoustic to electric conversion.T. JinR. YangY. WangY. FengK. TangNature PortfolioarticleMedicineRScienceQENScientific Reports, Vol 7, Iss 1, Pp 1-8 (2017)
institution DOAJ
collection DOAJ
language EN
topic Medicine
R
Science
Q
spellingShingle Medicine
R
Science
Q
T. Jin
R. Yang
Y. Wang
Y. Feng
K. Tang
Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
description Abstract Environmentally friendly and low-cost technologies to recover low-grade heat source into usable energy can contribute to ease the energy shortage. Thermoacoustic technology is expected as one promising approach in this ascendant field. In this work, the multi-stage looped thermoacoustic prime movers with asymmetric configuration, which can provide travelling-wave resonator and appropriate acoustic field for efficient regenerator, have been proposed and experimentally studied. The presented looped thermoacoustic prime movers can start to oscillate with quite low temperature difference along the regenerator. The lowest onset temperature difference obtained in the experiments is only 17 °C (the corresponding heating temperature is 29 °C), which can be achieved in both three-stage and four-stage looped thermoacoustic prime movers, with CO2 of 1 MPa or 1.5 MPa as the working fluid. An electric generator driven by a three-stage looped thermoacoustic prime mover with low heating temperature was tested to achieve the acoustic to electric conversion.
format article
author T. Jin
R. Yang
Y. Wang
Y. Feng
K. Tang
author_facet T. Jin
R. Yang
Y. Wang
Y. Feng
K. Tang
author_sort T. Jin
title Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
title_short Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
title_full Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
title_fullStr Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
title_full_unstemmed Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
title_sort low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
publisher Nature Portfolio
publishDate 2017
url https://doaj.org/article/6f78aa377230405cb6cf06cf8197ddf4
work_keys_str_mv AT tjin lowtemperaturedifferencethermoacousticprimemoverwithasymmetricmultistageloopconfiguration
AT ryang lowtemperaturedifferencethermoacousticprimemoverwithasymmetricmultistageloopconfiguration
AT ywang lowtemperaturedifferencethermoacousticprimemoverwithasymmetricmultistageloopconfiguration
AT yfeng lowtemperaturedifferencethermoacousticprimemoverwithasymmetricmultistageloopconfiguration
AT ktang lowtemperaturedifferencethermoacousticprimemoverwithasymmetricmultistageloopconfiguration
_version_ 1718384967338164224